EXACTECHGPS I00020Recalls & reported problems
Exactech, Inc. · STATION · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10885862252821), received between May 21, 2019 and Nov 15, 2023 — classified as 2 injuries.
The most frequently reported specific device problem is “Computer Operating System Problem” (1 report).
1 other recall cover devices cleared under the same FDA submission (K100742, K152764); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Computer Operating System Problem1
- Contamination /Decontamination Problem1
- Display or Visual Feedback Problem1
Patient problems
- Bone Fracture(s)1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryNov 15, 2023Display or Visual Feedback Problem; Display or Visual Feedback Problem
IT WAS REPORTED THAT DURING A SHOULDER PROCEDURE, A ¿STRANGE¿ PHENOMENON WITH GPS UNIT SERIAL (B)(6) OCCURRED WHERE NEITHER THE REPRESENTATIVE NOR THE SALES MANAGER COULD FIND AN EXPLANATION. THE SURGEON FOUND A DISCREPANCY BETWEEN THE PLANNED CENTRAL HOLE / PEG POSITION, AND WHAT WAS DETERMINED INTRA-OPERATIVELY. THE GPS UNIT SEEMS TO HAVE HAD AN ISSUE WITH ACCURACY. THEY WENT BACK TO THE ACQUISITION SCREEN AFTER THE SURGEON SAID HE PERFORATED THE FAULT AND WAS QUESTIONING THE ACCURACY OF THE PILOT TIP AND THAT IT CAUSED THE ERROR, SO THE REP HAD THE SURGEON GO BACK AND PICK A FEW POINTS TO SHOW THEY WERE GOOD. THE SURGEON WAS STILL CONVINCED THEY WERE OFF AND HE RE-DID THE CENTRAL PEG WHERE HE FELT WAS BETTER. FROM THE REPS MEMORY, THE SURGEON USED THE SCANS AND VISUALIZATION TO DETERMINE A REAMING POSITION THAT BETTER FIT THE IMPLANT IN THE GLENOID TO AVOID PERFORATION OF THE PEG. AFTER REPOSITIONING THE REAMER TO A POSITION, HE FELT BETTER MATCHED WHAT WAS REQUIRED, THE BASEPLATE WAS INSERTED, AND THE SURGEON WAS HAPPY WITH THE FINAL OUTCOME. THE PERFORATION OF THE BONE WAS RESOLVED BY REPOSITIONING THE K-WIRE/IMPLANT TO A BETTER POSITION, TO POSITION THE IMPLANT INSIDE THE GLE
Patient problems: Bone Fracture(s)
MAUDE report 18144001 ↗InjuryMay 21, 2019Contamination /Decontamination Problem; Computer Operating System Problem
DURING THE SECOND GPS+ CASE OF THE DAY, DR. (B)(6) EXPERIENCED THE FOLLOWING: TRACKER ACQUISITION WAS A PROBLEM. INTERESTINGLY THE F TRACKER. WOULD NOT COMPLETE ACQUISITION THAT LED TO DECISION TO REBOOT BECAUSE IT WOULD NOT RE-ACQUIRE. ENDED UP REBOOTING COMPUTER AND REMOVING BATTERIES, RE-ACQUIRING TRACKERS. HIP CENTER - ACQUIRED WITHOUT DIFFICULTY. IM GUIDED - PINNING WITHOUT DIFFICULTY. G - SLOT GUIDE - READ 6 DEGREES VARUS. HAD MORE DIFFICULTY THAT USUALLY ACQUIRING ACCURACY. THE PATIENT IS SHORT - 4¿ 11 ¿ AND DEPTH OF RESECTION SEEMED REASONABLE. THE SPACER BLOCKS CONFIRMED THAT THE CUT WAS WAY OFF. CONVERTED TO CC FEMUR AND OLD SCHOOL - ALIGNMENT ROD AND BOVIE CORD - FIXED THE SOFT TISSUE BALANCE AND PROBLEM. AFTER DISCUSSION WITH THE DOCTOR, IT WAS DETERMINED THAT THE LIKELY CAUSE OF THE EVENT WAS THE "SMUDGE" ON THE CAMERA OF THE GPS UNIT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8627240 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K100742, K152764. One submission often covers many models, so check the product and lot details in each record.
- Z-1149-2020 · Sep 22, 2019 · TerminatedBlue Ortho TKA Pro v2.1 software installed on the Exactech GPS system -indicated for stereotaxic surgery in Knee Arthroplasty Catalog Reference: L00002
Other Neurological Stereotaxic Instrument devices
- StealthStation S8 Platform 9735665Medtronic Navigation, Inc. · Neurological stereotaxic Instrument4 deaths4,668 reports
- Stealthstation® S7™ 9733856Medtronic Navigation, Inc. · Neurological stereotaxic Instrument6 deaths3,908 reports
- StealthStation S8 Platform 9735665Medtronic Navigation, Inc. · Neurological stereotaxic Instrument1 death1,896 reports
- StealthStation S8 9735669Medtronic Navigation, Inc. · Neurological stereotaxic Instrument1,831 reports
- StealthStation S8 Platform 9735665Medtronic Navigation, Inc. · Neurological stereotaxic Instrument2 deaths1,542 reports
- Fusion™ ENT Image Guidance System 9733560XOMMedtronic Navigation, Inc. · Neurological stereotaxic Instrument1,316 reports
- Stealthstation® S7™ 9733858Medtronic Navigation, Inc. · Neurological stereotaxic Instrument8 deaths984 reports
- Stealthstation® S7™ 9733858Medtronic Navigation, Inc. · Neurological stereotaxic Instrument1 death695 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page