Alteon 180-65-30Recalls & reported problems

Exactech, Inc. · Class 2

All models of Alteon (135)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10885862272669), received between May 14, 2020 and Jan 6, 2025 — classified as 2 injuries.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1
  • Loosening of Implant Not Related to Bone-Ingrowth1

Patient problems

  • Device Embedded In Tissue or Plaque1
  • Failure of Implant1
  • Joint Laxity1
  • Osteolysis1
  • Pain1
  • Synovitis1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 6, 2025Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth

    AS REPORTED VIA LEGAL DOCUMENTATION, A PATIENT HAD RIGHT HIP REPLACEMENT SURGERY ON (B)(6) 2018. THEY UNDERWENT RIGHT HIP REVISION SURGERY ON (B)(6) 2023, APPROXIMATELY 4 YEARS 8 MONTHS AFTER THEIR INITIAL IMPLANTATION. THE PATIENT CLAIMS TO HAVE SUFFERED FROM EXTREME PAIN, LIMPING, INSTABILITY AND A REVISION SURGERY AS A RESULT OF THIS DEVICE. PATIENT EXPERIENCED PROTHESIS WEAR, LOOSENING, SYNOVITIS, FAILURE OF IMPLANT, OSTEOLYSIS, JOINT LAXITY AND PAIN. THERE IS NO OTHER PATIENT DEMOGRAPHIC OR MEDICAL HISTORY AVAILABLE. PER THE REVISION OPERATIVE NOTES, "THE STEM WAS WELL FIXED. I [SURGEON] USED A BONE TAMP AND REMOVED THE CERAMIC HEAD. THE TRUNNION WAS IN GOOD CONDITION. ¿ I USED A SCREWDRIVER AND REMOVED THE ACETABULAR LINER AND COULD SEE SIGNIFICANT WEAR SUPEROLATERALLY. I USED A SCREWDRIVER AND REMOVED THE SCREWS IN THE ACETABULUM. THESE SCREWS NO LONGER HAD PURCHASE. THERE WAS OSTEOLYSIS AROUND THE SCREWS AND THEY WERE LOOSE. ¿ THE CUP WAS STABLE AND WELL FIXED." BASED ON THE EVENT DESCRIPTION, THE WEAR ON THE TIBIAL INSERT APPEARS TO BE UNEVEN. THIS COULD INDICATE INSTABILITY AND/OR RELATIVE COMPONENT MALPOSITION. ADDITIONALLY, THE POLYETHYLENE WEAR DEBRIS MAY HAVE CONTRIB

    Patient problems: Failure of Implant; Joint Laxity; Osteolysis; Pain; Synovitis

    MAUDE report 21078773 ↗
  • InjuryMay 14, 2020Break; Break

    AS REPORTED, DURING A PROCEDURE ON THIS (B)(6) FEMALE PATIENT, THE SURGEON BROKE OFF THE SCREW HEAD FROM THE SCREW BODY DURING INSERTION. IT WAS VERY HARD BONE AND THE TORQUE OF TRYING TO SEAT THE SCREW INTO THE ACETABULAR CUP CAUSED THE SCREW HEAD TO BREAK OFF. THE BROKEN SCREW HEAD WAS REMOVED HOWEVER THE SCREW BODY WAS LEFT INSIDE THE PATIENT. THE BODY OF THE SCREW WAS LEFT INSIDE THE PATIENT PAST THE HOLE OF THE ALREADY SEATED ACETABULAR CUP. PATIENT WAS LAST KNOWN TO BE IN STABLE CONDITION FOLLOWING THE EVENT.

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 10055614 ↗

Other Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented devices

All Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented devices →