Truliant 02-022-47-5013Recalls & reported problems

Exactech, Inc. · Class 2 · Implant

All models of Truliant (414)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
1

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10885862306593), received between Oct 18, 2023 and Oct 18, 2023 — classified as 1 injury.

The most frequently reported specific device problem is “Mechanical Problem” (1 report).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Aug 30, 2021Class IIOpen, Classified

    Inserts were packaged in vacuum bags that lacked an additional oxygen barrier layer.

    Z-0023-2022 · Root cause: Process control · Recall details · FDA record ↗

Most reported problems

Device problems

  • Mechanical Problem1
  • Naturally Worn1

Patient problems

  • Failure of Implant1
  • Joint effusion1
  • Loss of Range of Motion1
  • Pain1
  • Scar Tissue1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 18, 2023Mechanical Problem; Naturally Worn; Mechanical Problem; Naturally Worn

    AS REPORTED VIA LEGAL DOCUMENTATION THE PATIENT HAD A LEFT KNEE REPLACEMENT ON (B)(6) 2021. OVER THE NEXT SEVERAL MONTHS, THE PATIENT UNDERWENT PHYSICAL THERAPY SESSIONS AND FOLLOW UP APPOINTMENTS WITH THE SURGEON, AS WELL AS INJECTIONS TO HIS LEFT KNEE. APPROXIMATELY 10 MONTHS AFTER THE INITIAL PROCEDURE THE PATIENT HAD A LEFT KNEE REVISION ON (B)(6) 2022 TO REMOVE THE POLYETHYLENE, CAUSING THE INJURIES AND DAMAGES COMPLAINED OF. THERE IS NO OTHER PATIENT DEMOGRAPHIC OR MEDICAL HISTORY AVAILABLE. THERE IS NO DEVICE RETURN. THERE ARE NO PHOTOS OR OTHER IMAGES OF THE DEVICE PROVIDED. NO ADDITIONAL INFORMATION IS AVAILABLE. REVISION OP REPORT ON (B)(6) 2022. DIAGNOSIS: PAINFUL LEFT TOTAL KNEE, POLYETHYLENE WEAR. AT THE TIME OF SURGERY THERE WAS SOME MINOR WEAR OF THE POLYETHYLENE ON BOTH THE LATERAL AND MEDIAL TIBIAL SURFACES WITH SOME MORE SIGNIFICANT WEAR ALONG THE POSTERIOR MEDIAL CORNER OF THE POLYETHYLENE. THE FEMORAL AND TIBIAL COMPONENTS WERE INTACT. THE 13MM POLYETHYLENE WAS EXCHANGED FOR A NEW 15 MM POLYETHYLENE AND THE KNEE SHOWED EXCELLENT RANGE OF MOTION AND STABILITY. THE PATIENT WAS ALSO NOTED TO HAVE HEAVY SCAR TISSUE THROUGHOUT THE JOINT CAPSULE. THE SCAR TISSUE WAS D

    Patient problems: Failure of Implant; Joint effusion; Loss of Range of Motion; Pain; Scar Tissue

    MAUDE report 17958175 ↗

Other Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer devices

All Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer devices →