Equinoxe 319-01-00Recalls & reported problems
Exactech, Inc. · STEMLESS PUNCH INSERTER · Class 2
All models of Equinoxe (305)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10885862538789), received between Oct 23, 2023 and Oct 23, 2023 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 23, 2023Break; Break
IT WAS REPORTED THAT THE SURGEON ATTACHED THE INSERTER TO THE SIZE 2 STEMLESS BROACH AND WENT TO BACK THE BROACH OUT AND THE HANDLE KEPT COMING LOOSE AFTER FURTHER LOOKING AT THE HANDLE IT WAS DISCOVERED THAT THE HANDLE HAD COME APART. ONE SMALL PART FROM THE TOP OF THE HANDLE FELL ON THE FLOOR AND THE OTHER PARTS OF THE HANDLE WERE SET ON THE BACK TABLE. SURGEON STILL NEEDED TO REMOVE THE SIZE 2 BROACH SO HE USED THE CAGE EXTRACTION INSTRUMENT FROM THE ERGO ANATOMIC TRAY. HE ATTACHED IT TO THE BROACH ALONG WITH A SMALL SLAP HAMMER AND BACK THE BROACH OUT WHICH CAME OUT. HE THEN PROCEEDED TO PUT IN THE FINAL IMPLANT AND RUN IT THOUGH A RANGE OF MOTION. THEN HE REPAIRED THE SUB SCAP AND CLOSED. PATIENT WAS LAST KNOWN TO BE IN STABLE CONDITION FOLLOWING THE EVENT. NO PART OFF PIECES FELL INTO THE WOUND SITE. NO IMAGES OR X-RAYS AVAILABLE. DEVICE WAS RETURNED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17984943 ↗
Other Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained devices
- Tornier Perform DWM003ATornier, Inc. · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained1 recall1 report
- Sidus® Stem-Free Shoulder 01.04555.500Zimmer GmbH · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained1 recall1 report
- DJO SURGICAL 520-08-021Encore Medical, L.P. · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained20 reports
- INHANCE 5200-00-036Depuy (Ireland) · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained17 reports
- Easytech Anatomical Shoulder System 314-0038Fx Solutions · Prosthesis, Total Anatomic Shoulder, Uncemented Metaphyseal Humeral Stem With No Diaphyseal Incursion, Semi-Constrained14 reports
- Tornier Simpliciti® Shoulder System 7122872Tornier, Inc. · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained9 reports
- Sidus® Stem-Free Shoulder 01.04555.110Zimmer GmbH · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained6 reports
- GLOBAL ICON 1140-10-054Depuy (Ireland) · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained6 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page