Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10885862559296), received between Oct 10, 2024 and Dec 10, 2024 — classified as 2 injuries.
The most frequently reported specific device problem is “Lack of Effect” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Lack of Effect1
- Loosening of Implant Not Related to Bone-Ingrowth1
Patient problems
- Inadequate Osseointegration1
- Loss of Range of Motion1
- Osteolysis1
- Pain1
- Unspecified Infection1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryDec 10, 2024Lack of Effect; Lack of Effect
APPROXIMATELY 3 YEAR(S), 8 MONTH(S) AND 14 DAY(S) POST-OPERATIVE OF A RIGHT TSA, IT WAS REPORTED VIA CLINICAL STUDY THAT THE PATIENT EXPERIENCED ASEPTIC GLENOID LOOSENING. PATIENT DEVELOPED SHOULDER PAIN ABOUT 3 MONTHS AGO WITH INCREASING PAIN, CHANGING ROM, AND NIGHT PAIN. RADIOLUCENCY OVER GLENOID PEG AND PERI-HARDWARE; OSTEOLYSIS OVER STEMLESS HUMERAL COMPONENT. THE PATIENT WAS ADMINISTERED ESR/CRP TO RULE OUT INFECTION WITH PLAN FOR REVISION TO REVERSE (TYPE UNSPECIFIED) PENDING LABS. IN A RECENT UPDATE, THE PATIENT UNDERWENT A STANDARD TOTAL WITH STEMLESS REVISION, WITH THE REPORTED REMOVAL OF THE GLENOID, STEMLESS HUMERAL HEAD, AND STEMLESS HUMERAL CAGE COMPONENTS. THE OUTCOME OF THIS EVENT IS NOW CONSIDERED RESOLVED AND THE CASE REPORT FORM INDICATES THAT THIS EVENT IS POSSIBLY RELATED TO THE DEVICE AND/OR TO THE PROCEDURE. THIS WAS REPORTED THROUGH CLINICAL TRIAL STUDY DATA COLLECTION ACTIVITIES AND NO OTHER INFORMATION IS AVAILABLE AT THIS TIME.
Patient problems: Inadequate Osseointegration; Loss of Range of Motion; Osteolysis; Pain
MAUDE report 20895061 ↗InjuryOct 10, 2024Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth
AS REPORTED, APPROXIMATELY 2 YEARS POST THE INITIAL LEFT TOTAL SHOULDER ARTHROPLASTY, THE PATIENT WAS REVISED DUE TO LOOSENING. THE COMPONENTS WERE REMOVED AND AN ANTIBIOTIC SPACER WAS IMPLANTED. THE PATIENT WAS NOT REVISED TO EXACTECH DEVICES. THERE WAS NO REPORTED BREAKAGE OF A DEVICE OR SURGICAL DELAY/PROLONGATION. THE PATIENT WAS LAST KNOWN TO BE IN STABLE CONDITION FOLLOWING THE EVENT.
Patient problems: Unspecified Infection
MAUDE report 20422598 ↗
Other Prosthesis, Total Anatomic Shoulder, Uncemented Metaphyseal Humeral Stem With No Diaphyseal Incursion, Semi-Constrained devices
- Tornier Perform DWM003ATornier, Inc. · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained1 recall1 report
- Sidus® Stem-Free Shoulder 01.04555.500Zimmer GmbH · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained1 recall1 report
- DJO SURGICAL 520-08-021Encore Medical, L.P. · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained20 reports
- INHANCE 5200-00-036Depuy (Ireland) · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained17 reports
- Easytech Anatomical Shoulder System 314-0038Fx Solutions · Prosthesis, Total Anatomic Shoulder, Uncemented Metaphyseal Humeral Stem With No Diaphyseal Incursion, Semi-Constrained14 reports
- Tornier Simpliciti® Shoulder System 7122872Tornier, Inc. · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained9 reports
- GLOBAL ICON 1140-10-054Depuy (Ireland) · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained6 reports
- Sidus® Stem-Free Shoulder 01.04555.110Zimmer GmbH · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained6 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page