PROWLER 606-051FXRecalls & reported problems
Medos International Sàrl · PROWLER 10 Infusion Catheter with 2 Markers Infusion Catheter 2.3F (0.75 mm) 1.7F (0.55 mm) .015 Inch (0.4 mm) 3 cm 50 cm 150 cm MP Contents: 1 Infusion Catheter and 1 Shape Mandrel. Minimum Guiding Catheter I.D. / Dia. .035 Inch (0.9 mm) · Class 2
All models of PROWLER (8)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886704028529), received between May 6, 2020 and May 6, 2020 — classified as 1 injury.
The most frequently reported specific device problem is “Physical Resistance/Sticking” (1 report).
1 other recall cover devices cleared under the same FDA submission (K003925, K993266); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Physical Resistance/Sticking1
Patient problems
- Hemorrhage, Subarachnoid1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMay 6, 2020Physical Resistance/Sticking; Physical Resistance/Sticking
A REPORT FROM THE FIELD INDICATED THAT SHORTLY BEFORE A 2X4 HYPERSOFT (MICROVENTION) COIL WAS COMPLETELY INSIDE THE ANEURYSM AND ABOUT TO BE DETACHED, THE COIL COULD NEITHER BE PUSHED NOR PULLED. THE PROWLER10 45TIP 2MRK (606051FX/17751954) PRE-SHAPED MICROCATHETER WAS ¿STRETCHED SO THE COIL TORN THROUGH¿. THE COIL WAS DAMAGED ¿AT THE JOINT BETWEEN THE COIL ITSELF AND THE PUSHER WIRE¿. PART OF THE COIL REMAINED IN THE CATHETER AND THE REST OF THE COIL IN THE PATIENT. THE ¿STRETCHED¿ COIL WAS ¿CATCHED¿ IN THE LONG SHEATH USING A STENT RETRIEVER. THERE WAS NO REPORT OF ADVERSE OUTCOME TO THE PATIENT. A 3X10 HYPERSOFT (MICROVENTION) COIL WAS USED PRIOR TO THE COMPLAINT COIL AND THERE WERE NO ISSUES ENCOUNTERED DURING ADVANCEMENT OR DETACHMENT. THE MICROCATHETER HAD NOT BEEN RE-SHAPED AFTER REMOVAL FROM THE PACKAGING AND THE DEVICE HAD NOT BEEN INSERTED THROUGH A STOPCOCK INSTEAD OF A HEMOSTASIS VALVE. THE PHYSICIAN DID NOT HAVE ¿ANY PROBLEMS WHILE PROBING THE VESSELS WITH MICROWIRE AND MICROCATHETER¿. THE COMPLAINT MICROCATHETER AND PART OF THE 2X4 HYPERSOFT COIL WILL BE RETURNED FOR EVALUATION. NO FURTHER INFORMATION WAS PROVIDED. ADDITIONAL INFORMATION RECEIVED ON 05-MAY-2020 INDICA
Patient problems: Hemorrhage, Subarachnoid
MAUDE report 10028646 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K003925, K993266. One submission often covers many models, so check the product and lot details in each record.
- Z-0018-04 · Oct 19, 2001 · TerminatedProduct is labeled as Cordis Pre-shaped Prowler Plus MP Infusion Catheter (3 F proximal OD, 2.3 F Distal OD, 45 cm distal length, total length 155 cm) with an MP (45 degree) dual
Other Catheter, continuous flush devices
- PROWLER SELECT 606-S255XMedos International Sàrl · Catheter, continuous flush2 deaths980 reports
- PhenomTM 27 Catheter FG15150-0615-1SMicro Therapeutics, Inc. · Catheter, continuous flush2 deaths139 reports
- MarathonTM 105-5056Micro Therapeutics, Inc. · Catheter, continuous flush124 reports
- MarksmanTM FA-55150-1030Micro Therapeutics, Inc. · Catheter, continuous flush109 reports
- Renegade™ HI-FLO™ Kit M001183020Boston Scientific Corporation · Catheter, continuous flush109 reports
- EkoSonic® 6779-002Boston Scientific Corporation · Catheter, Continuous Flush1 recall4 deaths56 reports
- Chameleon CH08-40-75USMozarc Medical US LLC · Catheter, continuous flush2 recalls4 reports
- RebarTM 105-5081-153Micro Therapeutics, Inc. · Catheter, continuous flush2 deaths102 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.