PROWLER SELECT 606-S252XRecalls & reported problems
Medos International Sàrl · PROWLER SELECT PLUS TIP MARKERS 2 TIPSHAPE STRAIGHT Infusion Catheter 2.8F (0.95mm) 2.3F (0.75mm) .021 Inch (0.5mm) 15cm 150cm Contents: 1 Infusion Catheter and 1 Shape Mandrel. Minimum Guiding Catheter I.D. / Dia. .042 Inch (1.1mm) · Class 2
All models of PROWLER SELECT (9)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886704028840), received between Dec 11, 2018 and Dec 11, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Physical Resistance/Sticking” (1 report).
2 other recalls cover devices cleared under the same FDA submission (K021591); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Physical Resistance/Sticking1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 11, 2018Physical Resistance/Sticking; Physical Resistance/Sticking
THE HEALTHCARE PROFESSIONAL REPORTED THAT DURING THE PROCEDURE USING THE Y-STENT TECHNIQUE TO TREAT A BIFURCATION ANEURYSM AT THE RIGHT MIDDLE CEREBRAL ARTERY (MCA), THE 150CM X 15CM PROWLER SELECT PLUS MICROCATHETER (606S252X / 30066727) WAS PROPERLY POSITIONED AT THE TARGET POSITION AND USED WITH TWO 4.5MM X 22MM ENTERPRISE® VASCULAR RECONSTRUCTION DEVICES (ENC452212) FROM THE SAME LOT (10906474). THE FIRST ENTERPRISE STENT COULD NOT BE INTRODUCED INTO THE MICROCATHETER. THE SECOND ENTERPRISE STENT WAS SUCCESSFULLY INTRODUCED INTO THE MICROCATHETER, BUT THE DELIVERY WIRE WAS MET WITH RESISTANCE AND COULD NOT BE ADVANCED. THE PROWLER SELECT PLUS WAS REPLACED WITH THE VASCO MICROCATHETER (AIT BALT) AND THE 4.5MM X 22MM ENTERPRISE® VASCULAR RECONSTRUCTION DEVICE FROM LOT 10911251 WAS SUCCESSFULLY INTRODUCED INTO THE MICROCATHETER AND SUCCESSFULLY POSITIONED AND DEPLOYED AT THE TARGET SITE AND THE PROCEDURE WAS COMPLETED AS PLANNED WITHOUT COMPLICATIONS. THERE WAS NO REPORT OF PATIENT CONSEQUENCE OR ADVERSE EVENT. IT WAS REPORTED THAT THE PROWLER SELECT PLUS MICROCATHETER IS NOT AVAILABLE FOR RETURN.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8152404 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K021591. One submission often covers many models, so check the product and lot details in each record.
Other Catheter, continuous flush devices
- PROWLER SELECT 606-S255XMedos International Sàrl · Catheter, continuous flush2 deaths980 reports
- PhenomTM 27 Catheter FG15150-0615-1SMicro Therapeutics, Inc. · Catheter, continuous flush2 deaths139 reports
- MarathonTM 105-5056Micro Therapeutics, Inc. · Catheter, continuous flush124 reports
- MarksmanTM FA-55150-1030Micro Therapeutics, Inc. · Catheter, continuous flush109 reports
- Renegade™ HI-FLO™ Kit M001183020Boston Scientific Corporation · Catheter, continuous flush109 reports
- EkoSonic® 6779-002Boston Scientific Corporation · Catheter, Continuous Flush1 recall4 deaths56 reports
- Chameleon CH08-40-75USMozarc Medical US LLC · Catheter, continuous flush2 recalls4 reports
- RebarTM 105-5081-153Micro Therapeutics, Inc. · Catheter, continuous flush2 deaths102 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page