CODMAN BACTISEAL NS0339Recalls & reported problems

Cerenovus, Inc. · CODMAN BACTISEAL Clear with Barium Stripe Distal Catheter, 120cm Includes: Information Manual · Class 2 · Implant

All models of CODMAN BACTISEAL (7)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886704045168), received between Nov 8, 2022 and Nov 8, 2022 — classified as 1 injury.

1 other recall cover devices cleared under the same FDA submission (K031123); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Confusion/ Disorientation1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 8, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    1 OF 2 REPORTS. OTHER MFG REPORT NUMBER: 3013886523-2022-00543. A FACILITY REPORTED A CERTAS VALVE (ID 828804) WAS IMPLANTED VIA UNKNOWN SHUNT ON UNKNOWN DATE / SETTING. THE VALVE WAS USED WITH THE SILASCON LUMBAR CATHETER (MANUFACTURED BY KANEKA, PRODUCT CODE: 702-JJ). AND BACTISEAL PERITONEAL CATHETER (ID NS0339 SERIAL; UNK). ON (B)(6) 2022, THE PATIENT PRESENTED WITH DISORIENTATION AND SHUNT IMAGING WAS PERFORMED. VENTRICULAR ENLARGEMENT WAS OBSERVED; THEREFORE, SHUNT OBSTRUCTION WAS SUSPECTED, AND LUMBER CATHETER RUPTURE WAS ALSO CONFIRMED THE VALVE WAS REMOVED AND REPLACED ON (B)(6) 2022.

    Patient problems: Confusion/ Disorientation

    MAUDE report 15753855 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K031123. One submission often covers many models, so check the product and lot details in each record.

  • Z-1354-2021 · Mar 17, 2021 · Terminated
    CODMAN HAKIM BACTISEAL Shunt System Clear with Barium Stripe Peritoneal Catheter 120cm, with drainage Holes and Marking. For use in the treatment of hydrocephalus. Catalog Numb

Other Shunt, central nervous system and components devices

All Shunt, central nervous system and components devices →