BIOKNOTLESS ETHIBOND 212738Recalls & reported problems
Depuy Mitek, LLC · BIOKNOTLESS RC Anchor w/ETHIBOND PLA Absorbable Anchor, Size 1 (4 metric) ETHIBOND braided polyester suture anchor loop, Size 2/0 white ETHIBOND suture utility loop. · Class 2 · Implant
All models of BIOKNOTLESS ETHIBOND (2)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886705002238), received between Apr 23, 2019 and Apr 23, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Migration” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Migration1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 23, 2019Migration; Migration
DEVICE REPORT FROM SYNTHES (B)(6) REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT DURING AN ARCR SURGERY THE BIOKNOTLESS ETHIBOND ANCHOR CAME OFF FROM THE BONE HOLE WHEN THE SURGEON IMPLANTED INTO THE PATIENT'S SHOULDER. THUS, THE SURGEON COULD NOT IMPLANT AND FIX THE ANCHOR. THE SURGERY WAS FINISHED WITHOUT ANY OTHER PROBLEM, ALTHOUGH IT WAS NOT REPORTED HOW THE SURGERY WAS COMPLETED. THERE WERE NO BROKEN PARTS IN THE PATIENT¿S BODY. IT WAS BRAND NEW AND THE FIRST USE WHEN THE ISSUE OCCURRED. THERE WAS NO INFORMATION OF SURGICAL DELAY AND NO HARM TO THE PATIENT. NO FURTHER INFORMATION WAS PROVIDED BY THE HOSPITAL. THIS REPORT IS FOR A BIOKNOTLESS ETHIBOND ANCHOR. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8540443 ↗
Other STAPLE, FIXATION, BONE devices
- N/A StandardSynthes GmbH · Staple, Fixation, Bone2 recalls16 reports
- GII QUICKANCHOR ETHIBOND 212034Medos International Sàrl · STAPLE, FIXATION, BONE98 reports
- GII QUICKANCHOR ORTHOCORD 222983Medos International Sàrl · STAPLE, FIXATION, BONE94 reports
- Speed SE-0910Synthes GmbH · Staple, Fixation, Bone1 recall24 reports
- Speed Shift SE-2020-10Synthes GmbH · Staple, Fixation, Bone1 recall10 reports
- Lapiplasty SpeedPlate SK50Treace Medical Concepts, Inc. · Staple, Fixation, Bone59 reports
- Speed SE-1512Synthes GmbH · Staple, Fixation, Bone1 recall6 reports
- LUPINE ORTHOCORD 210709Depuy Mitek, LLC · STAPLE, FIXATION, BONE56 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.