IDEAL 251002Recalls & reported problems

Medos International Sàrl · IDEAL Suture Shuttle, 25 Degrees Right · Class 1

All models of IDEAL (7)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 10886705011636), received between Jan 18, 2019 and Nov 24, 2022 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Break” (6 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Break6

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • Not Applicable2
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 24, 2022Break; Break

    IT WAS REPORTED BY THE SALES REP THAT DURING A BANKART REPAIR PROCEDURE ON (B)(6) 2022, IT WAS OBSERVED THAT THE IDEAL SUTURE SHUTTLE 25 DEGREES RIGHT DEVICE BROKE DURING USE. ACCORDING TO THE REPORT, THE DISTAL, SILVER, METAL PART SEPARATED FROM THE WHITE, HANDLE PART. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE WITH A DELAY OF 10 MINUTES. THERE WERE NO ADVERSE PATIENT CONSEQUENCES REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15863442 ↗
  • MalfunctionMay 6, 2022Break; Break

    IT WAS REPORTED BY THE AFFILIATE IN (B)(6) THAT DURING AN UNKNOWN SURGERY ON (B)(6) 2022, IT WAS OBSERVED THAT THE WIRE ON THE SUTURE SHUTTLE DEVICE SNAPPED RIGHT AFTER THE BEGINNING OF ITS USE. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO ADVERSE PATIENT CONSEQUENCES NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14310715 ↗
  • MalfunctionOct 5, 2021Break; Break

    IT WAS REPORTED BY THE AFFILIATE IN (B)(6) THAT DURING AN UNKNOWN PROCEDURE ON (B)(6) 2021, IT WAS OBSERVED THAT THE KITE ON THE IDEAL SUTURE SHUTTLE 25 DEGREES RIGHT -G DEVICE COLLAPSED AND GOT OUT OF USE IN SPITE OF PLACING A SUTURE THROUGH THE KITE ONLY ONCE. THERE WERE NO FRAGMENTS OF THE COLLAPSED KITE LEFT IN THE PATIENT'S BODY. THERE WERE NO ADVERSE PATIENT CONSEQUENCES NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED. THE DEVICE WAS BRAND NEW AND THE FIRST USE WHEN THE ISSUE OCCURRED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12577018 ↗
  • MalfunctionSep 16, 2019Break; Break

    THIS IS REPORT 2 OF 2 FOR THE SAME EVENT. IT WAS REPORTED BY THE SALES REP VIA PHONE THAT DURING A LABRAL/SHOULDER PROCEDURE, IT WAS OBSERVED THE LOOP ON TWO OF THE CUSTOMER'S IDEAL SUTURE SHUTTLES 25 DEGREES RIGHT WERE BROKEN BUT STILL INTACT TO THE DEVICE. THE SALES REP CONFIRMED THAT NOTHING FELL IN THE PATIENT. THE PROCEDURE WAS COMPLETED WITH A THIRD LIKE DEVICE WITH NO HARM TO THE PATIENT BUT THERE WAS A TEN MINUTE DELAY TO OPEN A NEW DEVICE EACH TIME. THE SALES REP WAS NOT PRESENT FOR THE CASE THEREFORE COULD NOT PROVIDE ANY FURTHER INFORMATION. THE DEVICES WILL BE RETURNING FOR EVALUATION. THERE WAS A DELAY IN THE SURGICAL PROCEDURE. THERE WAS A SPARE DEVICE AVAILABLE FOR USE TO COMPLETE THE SURGERY. THERE WAS PATIENT INVOLVEMENT. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL MEDWATCH WILL BE SUBMITTED ACCORDINGLY.

    Patient problems: Not Applicable

    MAUDE report 9069612 ↗
  • MalfunctionSep 16, 2019Break; Break

    THIS IS REPORT 1 OF 2 FOR THE SAME EVENT. IT WAS REPORTED BY THE SALES REP VIA PHONE THAT DURING A LABRAL/SHOULDER PROCEDURE, IT WAS OBSERVED THE LOOP ON TWO OF THE CUSTOMER'S IDEAL SUTURE SHUTTLES 25 DEGREES RIGHT WERE BROKEN BUT STILL INTACT TO THE DEVICE. THE SALES REP CONFIRMED THAT NOTHING FELL IN THE PATIENT. THE PROCEDURE WAS COMPLETED WITH A THIRD LIKE DEVICE WITH NO HARM TO THE PATIENT BUT THERE WAS A TEN MINUTE DELAY TO OPEN A NEW DEVICE EACH TIME. THE SALES REP WAS NOT PRESENT FOR THE CASE THEREFORE COULD NOT PROVIDE ANY FURTHER INFORMATION. THE DEVICES WILL BE RETURNING FOR EVALUATION. THERE WAS A DELAY IN THE SURGICAL PROCEDURE. THERE WAS A SPARE DEVICE AVAILABLE FOR USE TO COMPLETE THE SURGERY. THERE WAS PATIENT INVOLVEMENT. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL MEDWATCH WILL BE SUBMITTED ACCORDINGLY.

    Patient problems: Not Applicable

    MAUDE report 9069611 ↗
  • MalfunctionJan 18, 2019Break; Break

    IT WAS REPORTED BY THE SALES REP THAT DURING A SHOULDER LABRAL PROCEDURE WHEN REMOVING THE CUSTOMER'S IDEAL SUTURE SHUTTLE 25 DEGREE RIGHT, THE IDEAL SUTURE SHUTTLE 25 DEGREES RIGHT -G DEVICE BROKE ON THE DISTAL TIP. THE SALES REP STATED THAT THE DEVICE BROKE OUTSIDE THE PATIENT. THE SALES REP REPORTED THAT THE SURGEON COMPLETED THE PROCEDURE WITH ANOTHER LIKE DEVICE WITH NO PATIENT CONSEQUENCES BUT THERE WAS A FIVE MINUTE DELAY. THE SALES REP STATED THAT THE DEVICE WAS DISCARDED. THERE WAS PATIENT INVOLVEMENT REPORTED. THERE WERE NO INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL MEDWATCH REPORT WILL BE SUBMITTED ACCORDINGLY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8261054 ↗

FDA clearance and classification

The FDA regulates product code HCF (instrument, ligature passing and knot tying) under 21 CFR 878.4800 as a Class I device. 21 CFR 878.4800 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the IDEAL 251002

Has the IDEAL 251002 been recalled?

No FDA recall record in our data names this exact device identifier (DI 10886705011636), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the IDEAL 251002?

The FDA's MAUDE database lists 6 adverse event reports for this device, received between Jan 18, 2019 and Nov 24, 2022. In those reports, the most common specific device problem is “Break” (6); the most common patient problem is “Not Applicable” (2). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the IDEAL 251002?

None of the reports are classified as deaths, 0 as injuries and 6 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the IDEAL 251002 FDA approved?

Devices of this type (product code HCF) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Medos International Sàrl.

Who makes the IDEAL 251002, and is it still sold?

The FDA's device database lists Medos International Sàrl as the company responsible for it (brand IDEAL, model 251002). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other INSTRUMENT, LIGATURE PASSING AND KNOT TYING devices

All INSTRUMENT, LIGATURE PASSING AND KNOT TYING devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page