IDEAL 251007Recalls & reported problems

Medos International Sàrl · IDEAL Suture Shuttle, Straight Crescent · Class 1

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 10886705011681), received between Jan 28, 2019 and Nov 19, 2024 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Break” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 3 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break5
  • Difficult to Advance1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 19, 2024Break; Break

    THIS IS REPORT 1 OF 2 FOR (B)(4). IT WAS REPORTED THAT DURING A LABRUM REPAIR PROCEDURE, IT WAS OBSERVED THAT THE DEVICE BROKE. THERE WAS A DELAY OF TWO MINUTES. IT WAS UNKNOWN IF THE PROCEDURE WAS COMPLETED. THERE WERE NO PATIENT CONSEQUENCES REPORTED. THE EXACT DATE OF THE EVENT WAS UNKNOWN BUT WAS NOTED TO HAVE OCCURRED IN 2024. NO ADDITIONAL INFORMATION PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20723485 ↗
  • MalfunctionNov 19, 2024Break; Break

    THIS IS REPORT 2 OF 2 FOR (B)(4). IT WAS REPORTED THAT DURING A LABRUM REPAIR PROCEDURE, IT WAS OBSERVED THAT THE DEVICE BROKE. THERE WAS A DELAY OF TWO MINUTES. IT WAS UNKNOWN IF THE PROCEDURE WAS COMPLETED. THERE WERE NO PATIENT CONSEQUENCES REPORTED. THE EXACT DATE OF THE EVENT WAS UNKNOWN BUT WAS NOTED TO HAVE OCCURRED IN 2024. NO ADDITIONAL INFORMATION PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20723285 ↗
  • MalfunctionNov 18, 2024Break; Break

    IT WAS REPORTED THAT DURING A ROTATOR CUFF REPAIR SURGICAL PROCEDURE IT WAS OBSERVED THAT THE CHIA WIRE WITHIN THE IDEAL SUTRE SHUTLE STRGHT CRESCENT -G BROKE AT THE TIP OF THE KITE. IT WAS REPORTED THAT THE BROKEN CHIA WAS REPLACED WITH ANOTHER CHIA WHICH ALSO BROKE AT THE KITE AREA OF THE CHIA PERCPASSER SUTURE PASSER. ANOTHER DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WAS A 10-MINUTE DELAY IN THE PROCEDURE DUE TO THE EVENT. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT. NO ADDITIONAL INFORMATION COULD BE PROVIDED. THIS IS REPORT 1 OF 2 FOR THE SAME EVENT IN (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20708000 ↗
  • MalfunctionApr 2, 2024Break; Break

    IT WAS REPORTED BY THE SALES REP THAT DURING AN UNSPECIFIED SURGICAL PROCEDURE ON (B)(6)2024 THE IDEAL SUTRE SHUTLE STRGHT CRESCENT -G DEVICE CHIA WIRE SNAPPED WHEN IT WAS GRABBED INSIDE THE JOINT. ANOTHER DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WAS A SLIGHT DELAY IN THE PROCEDURE. THERE WERE NO ADVERSE PATIENT CONSEQUENCES REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19020241 ↗
  • MalfunctionOct 20, 2021Difficult to Advance; Difficult to Advance

    IT WAS REPORTED BY THE SALES REP THAT DURING AN UNKNOWN PROCEDURE ON (B)(6) 2021, IT WAS OBSERVED THAT AFTER TAPPING THE ANCHOR AND PULLING OUT THE GUIDE ON THE IDEAL SUTRE SHUTLE STRGHT CRESCENT DEVICE, THE ANCHOR SUTURE CAME OUT WITH THE GUIDE. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO ADVERSE PATIENT CONSEQUENCES NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12667047 ↗
  • MalfunctionJan 28, 2019Break; Break

    THIS IS REPORT 2 OF 3 FOR THE SAME EVENT. IT WAS REPORTED BY THE AFFILIATE IN (B)(6) THAT DURING A LABRAL REPAIR SURGICAL PROCEDURE, IT WAS OBSERVED THAT THE NITINOL WIRE BROKE WHEN PULLING THE IDEAL SUTURE SHUTTLE 45 DEGREES LEFT TAPE THROUGH. IT WAS REPORTED THAT THIS HAPPENED ON THREE IDEAL SUTURE SHUTTLE 45 DEGREES LEFT DEVICES. ACCORDING TO THE REPORTER, THE SURGEON WAS PULLING GENTLY BUT THE DEVICES STILL BROKE. THE SURGEON OPENED THREE EXTRA SHUTTLES TO COMPLETE THE PROCEDURE WITH A 15 MINUTE DELAY. THERE WAS PATIENT INVOLVEMENT REPORTED. THERE WERE NO INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL MEDWATCH REPORT WILL BE SUBMITTED ACCORDINGLY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8282232 ↗

Other INSTRUMENT, LIGATURE PASSING AND KNOT TYING devices

All INSTRUMENT, LIGATURE PASSING AND KNOT TYING devices →