VA-LCP 03.111.730Recalls & reported problems
Synthes GmbH · SIZING TEMPLATE F/2.4MM VA-LCP 2-COL DSTL RAD PL 7H HD/RT · Class 1
All models of VA-LCP (256)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982072542), received between May 7, 2018 and May 7, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Failure to Align” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Failure to Align1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 7, 2018Failure to Align; Failure to Align
IT WAS REPORTED THAT THE PATIENT UNDERWENT AN OPEN REDUCTION INTERNAL FIXATION (ORIF) DUE TO A DISTAL RADIUS FRACTURE ON (B)(6) 2018. DURING THE SURGERY WHILE THE VARIABLE ANGLE (VA) LOCKING COMPRESSION PLATE (LCP) TWO COLUMN DISTAL RADIUS PLATE WAS BEING USED, TWO DIFFERENT DISTAL LOCKING HOLES IN THE HEAD OF THE PLATE DID NOT LOCK. IT WAS REPORTED THAT THE PLATE WHICH DID NOT LOCK WAS NOT IMPLANTED. THE SURGEON TRIED SEVERAL TIMES TO MAKE IT WORK, BUT HAD TO PULL IT OUT AND USED ANOTHER PLATE. THERE WAS A THIRTY (30) MINUTES SURGICAL DELAY REPORTED. THE FRACTURE OF THE PATIENT WAS FIXED APPROPRIATELY. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH NO HARM TO THE PATIENT. THIS REPORT IS FOR ONE (1) 2.4MM VA-LCP 2-CLMN VLR DSTL RADIUS PL 7H HD/3H SHAFT/RIGHT. THIS IS REPORT 1 OF 2 FOR (B)(4).
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7491375 ↗
Other TEMPLATE devices
- ATTUNE 2544-01-014Depuy (Ireland) · TEMPLATE802 reports
- ATTUNE 2545-00-546Depuy (Ireland) · TEMPLATE1 recall301 reports
- ARTICUL/EZE 2531-51-000Depuy (Ireland) · TEMPLATE323 reports
- DELTA XTEND 2307-95-000Depuy (Ireland) · TEMPLATE315 reports
- ATTUNE 2545-00-547Depuy (Ireland) · TEMPLATE1 recall231 reports
- ATTUNE 2544-00-520Depuy (Ireland) · TEMPLATE279 reports
- ATTUNE 2545-00-545Depuy (Ireland) · TEMPLATE1 recall221 reports
- ARTICUL/EZE 2530-91-000Depuy (Ireland) · TEMPLATE271 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page