NA 212.112Recalls & reported problems
Synthes GmbH · 3.5MM LOCKING SCREW SLF-TPNG W/STARDRIVE(TM) RECESS 32MM · Class 2 · Implant
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10886982151865), received between Apr 8, 2019 and Oct 29, 2021 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).
1 other recall cover devices cleared under the same FDA submission (K000684, K072095); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Device-Device Incompatibility1
Patient problems
- Impaired Healing1
- No Clinical Signs, Symptoms or Conditions1
- No Code Available1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 29, 2021Device-Device Incompatibility; Device-Device Incompatibility
IT WAS REPORTED THAT ON AN UNKNOWN DATE, DURING AN UNKNOWN PROCEDURE, THE SURGEON COMMENTED THAT THE DISTAL FIBULA PLATE WAS TOO BULKY AND DECIDED TO REMOVE IT IN EXCHANGE FOR A 1/3 TUBULAR PLATE ON THE FIBULA. WHILE USING A 1/3 TUBULAR ON THE MEDIAL SIDE OF THE TIBIA, THE SURGEON COULD NOT GET THE LOCKING MECHANISM TO FUNCTION, HOWEVER, IT WAS POSSIBLE THAT THE LOCKING HOLE WAS DEFORMED BY PUTTING A PREVIOUS NON-LOCKING SCREW. THERE WAS NO SURGICAL DELAY. THE PROCEDURE WAS SUCCESSFULLY COMPLETED. THERE WERE NO PATIENT CONSEQUENCES. THIS REPORT IS FOR ONE (1) 3.5 LCKNG SCREW SLF-TPNG W/SD(TM) REC 32. THIS IS REPORT 3 OF 3 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12719760 ↗InjuryApr 8, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT ON MARCH 14, 2019, THE PATIENT UNDERWENT REVISION OPEN REDUCTION INTERNAL FIXATION (ORIF) OF THE RIGHT PROXIMAL HUMERUS DUE TO NONUNION. THE FOLLOWING HARDWARE WAS REMOVED: ONE (1) LOCKING COMPRESSION PLATE (LCP) PROXIMAL HUMERUS PLATE-STANDARD 3H HEAD SHAFT. ONE (1) CORTEX SCREW SELF-TAPPING 34MM. ONE (1) CORTEX SCREW SELF-TAPPING 30MM. TWO (2) LOCKING SCREW SELF-TAPPING WITH STARDRIVE RECESS 52MM. ONE (1) LOCKING SCREW SELF-TAPPING WITH STARDRIVE (TM) RECESS 40MM. ONE (1) LOCKING SCREW SELF-TAPPING WITH STARDRIVE RECESS 48MM. ONE (1) LOCKING SCREW SELF-TAPPING WITH STARDRIVE (TM) RECESS 38MM. ONE (1) LOCKING SCREW SELF-TAPPING WITH STARDRIVE (TM) RECESS 50MM. ONE (1) LOCKING SCREW SELF-TAPPING WITH STARDRIVE RECESS 46MM. ONE (1) LOCKING SCREW SELF-TAPPING WITH STARDRIVE (TM) RECESS 32MM. HARDWARE WAS ORIGINALLY IMPLANTED ON DECEMBER 23, 2017. ALL HARDWARE WAS REMOVED SUCCESSFULLY AND INTACT. PROCEDURE WAS SUCCESSFULLY COMPLETED. PATIENT STATUS IS UNKNOWN. THIS REPORT IS FOR A 3.5MM LOCKING SCREW SELF-TAPPING WITH STARDRIVE RECESS(TM) 32MM. THIS IS REPORT 10 OF 10 FOR (B)(4). ADDITIONAL REPORTS ARE CAPTURED UNDER (B)(4).
Patient problems: Impaired Healing; No Code Available
MAUDE report 8492109 ↗
FDA clearance and classification
Cleared through 510(k) K072095 on Sep 27, 2007 (decision: Substantially Equivalent). Submitted by Synthes (Usa) as “Synthes (USA) Pediatric Lcp Hip Plate System Modifications”. The FDA review took 58 days. FDA record ↗
Cleared through 510(k) K000684 on Apr 28, 2000 (decision: Substantially Equivalent). Submitted by Synthes (Usa) as “Small Fragment Dynamic Compression Locking (Dcl) System”. The FDA review took 59 days. FDA record ↗
The FDA regulates product code KTT (appliance, fixation, nail/blade/plate combination, multiple component) under 21 CFR 888.3030 as a Class II device. 21 CFR 888.3030 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Recalls under the same FDA submission
These recalls involve devices cleared under K000684, K072095. One submission often covers many models, so check the product and lot details in each record.
- Z-1800-2015 · May 13, 2015 · Terminated3.7mm Cannulated Locking Screws and 3.7mm Cannulated Conical Screws; . the Cannulated Screws are indicated for fixation of fractures, osteotomies, and non-unions of the clavicle,
Common questions about the NA 212.112
Has the NA 212.112 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10886982151865), based on the FDA recall file dated Nov 27, 2026. However, 1 recall involves devices cleared under the same FDA submission. It may or may not include this model, so check the product, model and lot details in that record.
What problems have been reported with the NA 212.112?
The FDA's MAUDE database lists 2 adverse event reports for this device, received between Apr 8, 2019 and Oct 29, 2021. In those reports, the most common specific device problem is “Device-Device Incompatibility” (1); the most common patient problem is “Impaired Healing” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the NA 212.112?
None of the reports are classified as deaths, 1 as an injury and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the NA 212.112 FDA approved?
It was cleared through 510(k) K000684 on Apr 28, 2000; its record lists 2 FDA submissions in total. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the NA 212.112 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the NA 212.112, and is it still sold?
The FDA's device database lists Synthes GmbH as the company responsible for it (brand NA, model 212.112). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT devices
- PRECICE® Plating System LP4.5-DLF31Nuvasive Specialized Orthopedics, Inc. · Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component3 recalls0 reports
- R3 71364451Smith & Nephew, Inc. · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT145 reports
- DFS HA BONE SCREWS HAA60-15050Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT2 recalls0 reports
- DFS HA BONE SCREWS HAA60-11030Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT2 recalls0 reports
- DFS HA BONE SCREWS HAA60-15020Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT2 recalls0 reports
- DFS HA BONE SCREWS HAA60-18030Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT2 recalls0 reports
- DFS HA BONE SCREWS HAA60-15040Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT2 recalls0 reports
- DFS HA BONE SCREWS HAA60-15060Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT2 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page