Skip to content

NA 494.769Recalls & reported problems

Synthes GmbH · 4.0MM/2.5MM TI SELF-DRILLING SCHANZ SCREW 20MM THRD/80MM · Class 2 · Implant

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10886982236364), received between Oct 20, 2022 and Oct 20, 2022 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Device-Device Incompatibility” (2 reports).

5 other recalls cover devices cleared under the same FDA submission (K002605, K082650, K122455); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Device-Device Incompatibility2

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 20, 2022Device-Device Incompatibility; Device-Device Incompatibility

    DEVICE REPORT FROM JAPAN REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2022, THE PATIENT UNDERWENT EXTERNAL FIXATION FOR A DISTAL RADIUS FRACTURE WITH THE PRODUCTS IN QUESTION. WITH THE RODS AND CLAMPS OF A Z FRAME EXTERNAL FIXATOR, THE SURGEON ATTEMPTED TO DRILL A 2.5/4.0 SELDRILL USING A 4.0 MM THREADED DRILL SLEEVE, BUT THE SELDRILL JAMMED IN THE SLEEVE AND COULD NOT BE INSERTED INTO THE BONE. HE CHECKED IF HE HAD INSERTED THE SELDRILL AT AN ANGLE, BUT IT STILL DID NOT PASS. HE TRIED TO PUNCTURE WITH OTHER SELDRILLS, BUT ALL OF THEM EXPERIENCED INTERFERENCE IN THE SLEEVE. THE SURGEON WAS ABLE TO COMPLETE THIS STEP USING ANOTHER PRODUCT, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH A DELAY OF UNDER 30 MINUTES. AFTER CLEANING THE DRILL SLEEVE, IT IS FOUND THAT THE INSIDE OF THE SLEEVE THERE WAS A BURR-LIKE OBJECT HAD FORMED AROUND THE CIRCUMFERENCE OF THE SLEEVE, CAUSING THE 4.0 CELL DRILL TO POKE INTO IT. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR A 4.0MM/2.5MM TI SELF-DRILLING SCHANZ SCREW 20MM THRD/80MM. THIS IS REPORT 5 OF 5 FOR (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15639328 ↗
  • MalfunctionOct 20, 2022Device-Device Incompatibility; Device-Device Incompatibility

    DEVICE REPORT FROM JAPAN REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2022, THE PATIENT UNDERWENT EXTERNAL FIXATION FOR A DISTAL RADIUS FRACTURE WITH THE PRODUCTS IN QUESTION. WITH THE RODS AND CLAMPS OF A Z FRAME EXTERNAL FIXATOR, THE SURGEON ATTEMPTED TO DRILL A 2.5/4.0 SELDRILL USING A 4.0 MM THREADED DRILL SLEEVE, BUT THE SELDRILL JAMMED IN THE SLEEVE AND COULD NOT BE INSERTED INTO THE BONE. HE CHECKED IF HE HAD INSERTED THE SELDRILL AT AN ANGLE, BUT IT STILL DID NOT PASS. HE TRIED TO PUNCTURE WITH OTHER SELDRILLS, BUT ALL OF THEM EXPERIENCED INTERFERENCE IN THE SLEEVE. THE SURGEON WAS ABLE TO COMPLETE THIS STEP USING ANOTHER PRODUCT, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH A DELAY OF UNDER 30 MINUTES. AFTER CLEANING THE DRILL SLEEVE, IT IS FOUND THAT THE INSIDE OF THE SLEEVE THERE WAS A BURR-LIKE OBJECT HAD FORMED AROUND THE CIRCUMFERENCE OF THE SLEEVE, CAUSING THE 4.0 CELL DRILL TO POKE INTO IT. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR A 4.0MM/2.5MM TI SELF-DRILLING SCHANZ SCREW 20MM THRD/80MM. THIS IS REPORT 2 OF 5 FOR (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15639322 ↗

FDA clearance and classification

Cleared through 510(k) K122455 on Apr 11, 2013 (decision: Substantially Equivalent). Submitted by Synthes as “Synthes Small External Fixation System, Synthes Large External Fixation System”. The FDA review took 241 days. FDA record ↗

Cleared through 510(k) K082650 on Nov 18, 2008 (decision: Substantially Equivalent). Submitted by Synthes (Usa) as “Synthes Large External Fixation, Mr Conditional”. The FDA review took 67 days. FDA record ↗

Cleared through 510(k) K002605 on Nov 20, 2000 (decision: Substantially Equivalent). Submitted by Synthes (Usa) as “4.0/2.5 Mm Self-Drilling Schanz Screw”. The FDA review took 90 days. FDA record ↗

The FDA regulates product code JDW (pin, fixation, threaded) under 21 CFR 888.3040 as a Class II device. 21 CFR 888.3040 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K002605, K082650, K122455. One submission often covers many models, so check the product and lot details in each record.

  • Z-2451-2015 · Jul 29, 2015 · Terminated
    Synthes Trauma Ex-Fix System (Small, Medium, Distraction Osteogenesis (DO) and Large) ; (S) intended to stabilize and provide treatment for fractures of the small bones, such as th
  • Z-1833-2014 · Apr 10, 2014 · Terminated
    Synthes External Fixation Systems (Small, Medium, Large and DO), bone fixation appliance components.
  • Z-0941-2013 · Jan 11, 2013 · Terminated
    Large Combination Clamp/Large External Fixation System, Part Number 390.005 Product Usage: Synthes Large External Fixation is intended for use to provide treatment for long bone
  • Z-1816-2013 · Oct 12, 2012 · Open, Classified
    Synthes Large External Fixation, MR Conditional, Tube to Tube Clamp, Part Number 390.007, Lot Number 6800599 Synthes Large External Fixation is intended for use to provide treatme
  • Z-0277-2013 · Sep 28, 2012 · Terminated
    Synthes External Fixation System Tube to Tube Clamp, Part Number 390.007. Intended for use to provide treatment for long bone and pelvic fractures that require external fixation.

Common questions about the NA 494.769

Has the NA 494.769 been recalled?

No FDA recall record in our data names this exact device identifier (DI 10886982236364), based on the FDA recall file dated Nov 27, 2026. However, 5 recalls involve devices cleared under the same FDA submission. They may or may not include this model, so check the product, model and lot details in those records.

What problems have been reported with the NA 494.769?

The FDA's MAUDE database lists 2 adverse event reports for this device, received on Oct 20, 2022. In those reports, the most common specific device problem is “Device-Device Incompatibility” (2). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the NA 494.769?

None of the reports are classified as deaths, 0 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the NA 494.769 FDA approved?

It was cleared through 510(k) K002605 on Nov 20, 2000; its record lists 3 FDA submissions in total. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the NA 494.769 MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.

Who makes the NA 494.769, and is it still sold?

The FDA's device database lists Synthes GmbH as the company responsible for it (brand NA, model 494.769). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other PIN, FIXATION, THREADED devices

All PIN, FIXATION, THREADED devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page