NA 494.772Recalls & reported problems
Synthes GmbH · 4.0MM/3.0MM TI SELF-DRILLING SCHANZ SCREW 20MM THRD/100MM · Class 2 · Implant
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10886982236418), received between Oct 20, 2022 and Oct 20, 2022 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Device-Device Incompatibility” (2 reports).
6 other recalls cover devices cleared under the same FDA submission (K082650, K122455, K952296, K963618); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Device-Device Incompatibility2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 20, 2022Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM JAPAN REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2022, THE PATIENT UNDERWENT EXTERNAL FIXATION FOR A DISTAL RADIUS FRACTURE WITH THE PRODUCTS IN QUESTION. WITH THE RODS AND CLAMPS OF A Z FRAME EXTERNAL FIXATOR, THE SURGEON ATTEMPTED TO DRILL A 2.5/4.0 SELDRILL USING A 4.0 MM THREADED DRILL SLEEVE, BUT THE SELDRILL JAMMED IN THE SLEEVE AND COULD NOT BE INSERTED INTO THE BONE. HE CHECKED IF HE HAD INSERTED THE SELDRILL AT AN ANGLE, BUT IT STILL DID NOT PASS. HE TRIED TO PUNCTURE WITH OTHER SELDRILLS, BUT ALL OF THEM EXPERIENCED INTERFERENCE IN THE SLEEVE. THE SURGEON WAS ABLE TO COMPLETE THIS STEP USING ANOTHER PRODUCT, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH A DELAY OF UNDER 30 MINUTES. AFTER CLEANING THE DRILL SLEEVE, IT IS FOUND THAT THE INSIDE OF THE SLEEVE THERE WAS A BURR-LIKE OBJECT HAD FORMED AROUND THE CIRCUMFERENCE OF THE SLEEVE, CAUSING THE 4.0 CELL DRILL TO POKE INTO IT. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR A 4.0MM/3.0MM TI SELF-DRILLING SCHANZ SCREW 20MM THRD/100MM. THIS IS REPORT 4 OF 5 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15639327 ↗MalfunctionOct 20, 2022Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM JAPAN REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2022, THE PATIENT UNDERWENT EXTERNAL FIXATION FOR A DISTAL RADIUS FRACTURE WITH THE PRODUCTS IN QUESTION. WITH THE RODS AND CLAMPS OF A Z FRAME EXTERNAL FIXATOR, THE SURGEON ATTEMPTED TO DRILL A 2.5/4.0 SELDRILL USING A 4.0 MM THREADED DRILL SLEEVE, BUT THE SELDRILL JAMMED IN THE SLEEVE AND COULD NOT BE INSERTED INTO THE BONE. HE CHECKED IF HE HAD INSERTED THE SELDRILL AT AN ANGLE, BUT IT STILL DID NOT PASS. HE TRIED TO PUNCTURE WITH OTHER SELDRILLS, BUT ALL OF THEM EXPERIENCED INTERFERENCE IN THE SLEEVE. THE SURGEON WAS ABLE TO COMPLETE THIS STEP USING ANOTHER PRODUCT, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH A DELAY OF UNDER 30 MINUTES. AFTER CLEANING THE DRILL SLEEVE, IT IS FOUND THAT THE INSIDE OF THE SLEEVE THERE WAS A BURR-LIKE OBJECT HAD FORMED AROUND THE CIRCUMFERENCE OF THE SLEEVE, CAUSING THE 4.0 CELL DRILL TO POKE INTO IT. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR A 4.0MM/3.0MM TI SELF-DRILLING SCHANZ SCREW 20MM THRD/100MM. THIS IS REPORT 3 OF 5 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15639325 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K082650, K122455, K952296, K963618. One submission often covers many models, so check the product and lot details in each record.
- Z-0043-2018 · Sep 18, 2017 · TerminatedMicroPort Orthopedics SCHANZ SCREW SELF DRILL, SIZE 4mm, REF 20070057, STERILE R Product Usage: MPO Total Hip Systems are indicated for use in total hip arthroplasty for reduction
- Z-2451-2015 · Jul 29, 2015 · TerminatedSynthes Trauma Ex-Fix System (Small, Medium, Distraction Osteogenesis (DO) and Large) ; (S) intended to stabilize and provide treatment for fractures of the small bones, such as th
- Z-1833-2014 · Apr 10, 2014 · TerminatedSynthes External Fixation Systems (Small, Medium, Large and DO), bone fixation appliance components.
- Z-0941-2013 · Jan 11, 2013 · TerminatedLarge Combination Clamp/Large External Fixation System, Part Number 390.005 Product Usage: Synthes Large External Fixation is intended for use to provide treatment for long bone
- Z-1816-2013 · Oct 12, 2012 · Open, ClassifiedSynthes Large External Fixation, MR Conditional, Tube to Tube Clamp, Part Number 390.007, Lot Number 6800599 Synthes Large External Fixation is intended for use to provide treatme
- Z-0277-2013 · Sep 28, 2012 · TerminatedSynthes External Fixation System Tube to Tube Clamp, Part Number 390.007. Intended for use to provide treatment for long bone and pelvic fractures that require external fixation.
Other APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT devices
- PRECICE® Plating System LP4.5-DLF31Nuvasive Specialized Orthopedics, Inc. · Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component3 recalls0 reports
- R3 71364451Smith & Nephew, Inc. · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT145 reports
- DFS HA BONE SCREWS HAA60-15040Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT2 recalls0 reports
- DFS HA BONE SCREWS HAA60-15050Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT2 recalls0 reports
- DFS HA BONE SCREWS HAB60-12040Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT2 recalls0 reports
- DFS HA BONE SCREWS HAA60-13040Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT2 recalls0 reports
- DFS HA BONE SCREWS HAA60-18030Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT2 recalls0 reports
- DFS HA BONE SCREWS HAA60-15030Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT2 recalls0 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.