Skip to content

NA 532.018Recalls & reported problems

Synthes GmbH · HUDSON REDUCTION DRIVE UNIT · Class 1

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10886982240521), received between Jan 23, 2018 and Jul 14, 2021 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Device Inoperable” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Device Inoperable1
  • Device Operates Differently Than Expected1
  • Device-Device Incompatibility1
  • Premature Separation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 14, 2021Device-Device Incompatibility; Premature Separation; Device-Device Incompatibility; Premature Separation

    IT WAS REPORTED FROM (B)(6) THAT DURING SURGERY FOR A FEMORAL FRACTURE, IT WAS DISCOVERED THAT THE REDUCTION DRIVE DEVICE FAILED TO LOCK ONTO THE HANDPIECE DEVICE AND FELL OUT EASILY. IT WAS FURTHER REPORTED THAT THE SURGEON CONTINUED TO USE THE UNLOCKED DEVICES TO COMPLETE THE SURGERY WITHOUT ANY SURGICAL DELAY. IT WAS NOTED THAT ANOTHER ATTACHMENT DEVICE WAS ATTACHED TO THE HANDPIECE DEVICE WITHOUT ISSUE AND THE PROBLEM SEEMED TO BE WITH THE REDUCTION DRIVE DEVICE. THERE WAS PATIENT INVOLVEMENT REPORTED. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL MEDWATCH REPORT WILL BE SUBMITTED ACCORDINGLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12167196 ↗
  • MalfunctionJan 23, 2018Device Inoperable; Device Operates Differently Than Expected; Device Inoperable; Device Operates Differently Than Expected

    IT WAS REPORTED THAT DURING AN UNSPECIFIED SURGICAL PROCEDURE OF THE HIP IT WAS OBSERVED THAT THE REDUCTION DRIVE DEVICE WOULD NOT GO IN REVERSE. IT WAS REPORTED THAT THERE WAS NO DELAY IN THE PROCEDURE DUE TO THE EVENT WAS AN UNSPECIFIED SPARE DEVICE WAS AVAILABLE FOR USE. THERE WAS PATIENT INVOLVEMENT REPORTED. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL MEDWATCH WILL BE SUBMITTED ACCORDINGLY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7212965 ↗

FDA clearance and classification

The FDA regulates product code GFC (driver, surgical, pin) under 21 CFR 878.4820 as a Class I device. 21 CFR 878.4820 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the NA 532.018

Has the NA 532.018 been recalled?

No FDA recall record in our data names this exact device identifier (DI 10886982240521), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the NA 532.018?

The FDA's MAUDE database lists 2 adverse event reports for this device, received between Jan 23, 2018 and Jul 14, 2021. In those reports, the most common specific device problems are “Device Inoperable” (1), “Device Operates Differently Than Expected” (1) and “Device-Device Incompatibility” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the NA 532.018?

None of the reports are classified as deaths, 0 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the NA 532.018 FDA approved?

Devices of this type (product code GFC) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Synthes GmbH.

Who makes the NA 532.018, and is it still sold?

The FDA's device database lists Synthes GmbH as the company responsible for it (brand NA, model 532.018). Its record shows it as no longer in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other DRIVER, SURGICAL, PIN devices

All DRIVER, SURGICAL, PIN devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page