- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 10887587066004), received between Jun 29, 2017 and Dec 12, 2022 — classified as 4 injuries, 1 malfunction.
The most frequently reported specific device problem is “Fitting Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem3
- Appropriate Device Problem Term/Code Not Available1
- Fitting Problem1
- Manufacturing, Packaging or Shipping Problem1
Patient problems
- No Code Available2
- Unspecified Infection2
- No Consequences Or Impact To Patient1
- Swelling/ Edema1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
InjuryDec 12, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT IMPLANT WAS BEING REMOVED DUE TO INFECTION. THIS REPORT IS FOR ONE (1) PSI SD800.541 PEEK IMPLANT. THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).
Patient problems: Unspecified Infection
MAUDE report 15959026 ↗InjuryOct 31, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT ON AN UNKNOWN DATE, AN IMPLANT WAS REMOVED DUE TO COMPLICATIONS/SWELLING. IT IS UNKNOWN IF THERE WERE PATIENT AND PROCEDURE INVOLVEMENT. THIS REPORT IS FOR A PSI SD800.541 PEEK IMPLANT. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: Swelling/ Edema
MAUDE report 15698983 ↗InjuryApr 27, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT ON AN UNKNOWN DATE, THE PATIENT DEVELOPED SOFT TISSUE INFECTION ON SCALP, SO THE SURGEON HAD TO REMOVE THE PEEK IMPLANT TO TREAT THE INFECTION. AT A LATER DATE WHEN INFECTION RESIDES, A NEW PEEK IMPLANT WILL BE MADE AND IMPLANTED. SURGICAL DELAY AND PROCEDURE OUTCOME ARE UNKNOWN. PATIENT INVOLVEMENT WAS UNKNOWN. THIS COMPLAINT INVOLVES ONE (1) DEVICE. THIS REPORT IS FOR ONE (1) PSI SD800.541 PEEK IMPLANT. THIS REPORT IS 1 OF 3 FOR (B)(4).
Patient problems: No Code Available; Unspecified Infection
MAUDE report 10003265 ↗MalfunctionOct 17, 2019Manufacturing, Packaging or Shipping Problem; Appropriate Device Problem Term/Code Not Available; Manufacturing, Packaging or Shipping Problem; Appropriate Device Problem Term/Code Not Available
THE SURGEON COMPLETED THE SURGERY AND PLATE HAD SLIGHT GAP NEXT TO BONE. THERE WAS NO SURGICAL DELAY. THERE WILL BE NO REVISION SURGERY. THERE WAS NO INJURY TO THE PATIENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9200779 ↗InjuryJun 29, 2017Fitting Problem; Fitting Problem
IT WAS REPORTED THAT A PATIENT SPECIFIC IMPLANT (PSI) COULD NOT BE USED IN SURGERY DUE TO THE IMPLANT NOT FITTING PROPERLY. IT WAS FURTHER EXPLAINED THAT THE PSI WAS NOTED TO FIT ON ONE SIDE BUT NOT THE OTHER. THE SURGEON DECIDED TO CUT THE IMPLANT IN HALF AND GO AHEAD AND IMPLANT IT IN THE PATIENT AS PLANNED. THERE WAS AN UNKNOWN SURGICAL DELAY DUE TO THE CHANGE IN THE SURGICAL PLAN AND THE ADJUSTMENTS REQUIRED TO MAKE THE PSI FIT. IT IS UNKNOWN WHAT DEVICES WERE USED TO CUT THE IMPLANT IN HALF, WHAT DEVICES WERE USED TO ASSIST WITH THE FITTING. PLATES MAY HAVE BEEN USED TO SPAN THE MIDDLE OF THE PSI BUT THIS HAS NOT BEEN CONFIRMED. TO THE REPORTER'S KNOWLEDGE, THERE WAS NO HARM TO THE PATIENT. THE SURGEON IS CONSIDERING A REVISION BUT, TO DATE, A REVISION SURGERY HAS NOT BEEN SCHEDULED. THIS REPORT IS FOR ONE (1) PSI PEEK IMPLANT. THIS IS REPORT 1 OF 1 FOR COM-(B)(4).
Patient problems: No Code Available
MAUDE report 6679631 ↗
FDA clearance and classification
Cleared through Special 510(k) K053199 on Dec 14, 2005 (decision: Substantially Equivalent). Submitted by Synthes (Usa) as “Synthes Patient Specific Cranial/Craniofacial Implant”. The FDA review took 28 days. FDA record ↗
Cleared through 510(k) K033868 on Jun 21, 2004 (decision: Substantially Equivalent). Submitted by Synthes (Usa) as “Synthes (USA) Patient Specific Cranial/Craniofacial Implants”. The FDA review took 192 days. FDA record ↗
The FDA regulates product code GXN (plate, cranioplasty, preformed, non-alterable) under 21 CFR 882.5330 as a Class II device. 21 CFR 882.5330 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the NA SD800.541
Has the NA SD800.541 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10887587066004), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the NA SD800.541?
The FDA's MAUDE database lists 5 adverse event reports for this device, received between Jun 29, 2017 and Dec 12, 2022. In those reports, the most common specific device problems are “Fitting Problem” (1) and “Manufacturing, Packaging or Shipping Problem” (1); the most common patient problems are “Unspecified Infection” (2) and “Swelling/ Edema” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the NA SD800.541?
None of the reports are classified as deaths, 4 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the NA SD800.541 FDA approved?
It was cleared through 510(k) K033868 on Jun 21, 2004; its record lists 2 FDA submissions in total. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the NA SD800.541 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the NA SD800.541, and is it still sold?
The FDA's device database lists Synthes GmbH as the company responsible for it (brand NA, model SD800.541). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other PLATE, CRANIOPLASTY, PREFORMED, NON-ALTERABLE devices
- NA SD800.440Synthes GmbH · PLATE, CRANIOPLASTY, PREFORMED, NON-ALTERABLE22 reports
- AccuShape® MC-SPK30Medcad · Plate, Cranioplasty, Preformed, Non-Alterable13 reports
- AccuShape® MC-SPK40Medcad · Plate, Cranioplasty, Preformed, Non-Alterable13 reports
- NA SD800.434Synthes GmbH · PLATE, CRANIOPLASTY, PREFORMED, NON-ALTERABLE11 reports
- NA SD800.427Synthes GmbH · PLATE, CRANIOPLASTY, PREFORMED, NON-ALTERABLE8 reports
- NA SD800.433Synthes GmbH · PLATE, CRANIOPLASTY, PREFORMED, NON-ALTERABLE8 reports
- IPS 60-000-23-09KLS-Martin L.P. · PLATE, CRANIOPLASTY, PREFORMED, NON-ALTERABLE7 reports
- NA SD800.540Synthes GmbH · PLATE, CRANIOPLASTY, PREFORMED, NON-ALTERABLE6 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page