Natrelle Inspira Cohesive Breast Implants SCF-345Recalls & reported problems
Allergan, Inc. · Natrelle Inspira SCF 345cc Full profile |smooth|round|silicone · Class 3 · Implant
All models of Natrelle Breast Implants (1167) · Natrelle Inspira Cohesive Breast Implants (192)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
Quick summary
This Natrelle Inspira cohesive breast implant (SCF-345) is a smooth, round, full-profile silicone gel implant made by Allergan. The 45 reports mostly describe capsular contracture — the scar tissue around the implant tightening and hardening, sometimes severe enough that the implant had to be removed and replaced — along with a few cases of implant rupture, wound reopening, and infection. There are 45 injuries and no deaths. No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 45
- Deaths reported
- 0
- Injuries reported
- 45
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 45 adverse event reports that list this exact device (DI 10888628030091), received between Jun 24, 2019 and May 6, 2026 — classified as 45 injuries.
The most frequently reported specific device problem is “Device Appears to Trigger Rejection” (33 reports).
4 other recalls cover devices cleared under the same FDA submission (P020056); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Device Appears to Trigger Rejection33
- Patient-Device Incompatibility6
- Adverse Event Without Identified Device or Use Problem4
- Material Rupture3
Patient problems
- Capsular Contracture38
- Failure of Implant4
- Wound Dehiscence3
- Unspecified Infection1
Recent adverse event reports
The 25 most recent of 45 reports, in the reporter's own words as published by the FDA.
InjuryMay 6, 2026Device Appears to Trigger Rejection
HEALTHCARE PROFESSIONAL REPORTED "CAPSULAR CONTRACTURE BAKER GRADE LLL". THIS RECORD IS FOR RIGHT SIDE. THE DEVICE REMAINS IMPLANTED.
Patient problems: Capsular Contracture
MAUDE report 25105140 ↗InjuryNov 11, 2025Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
HEALTHCARE PROFESSIONAL REPORTED VIA NATIONAL BREAST IMPLANT REGISTRY (NBIR) A "CAPSULAR CONTRACTURE BAKER GRADE III". THIS RECORD IS FOR THE RIGHT SIDE. THE DEVICE WAS EXPLANTED AND REPLACED. IT IS UNKNOWN IF THE DEVICE WILL BE RETURNED.
Patient problems: Capsular Contracture
MAUDE report 23524007 ↗InjurySep 26, 2025Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
HEALTHCARE PROFESSIONAL LEFT SIDE "CAPSULAR CONTRACTURE BAKER GRADE IV" CONFIRMED VIA PHYSICAL EXAMINATION. PATIENT UNDERGONE PARTIAL CAPSULECTOMY. THE DEVICE HAS BEEN EXPLANTED AND REPLACED.
Patient problems: Capsular Contracture
MAUDE report 23159395 ↗InjurySep 24, 2025Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
InjuryAug 27, 2025Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
HEALTHCARE PROFESSIONAL REPORTED RIGHT SIDE "CAPSULE RECONTRACTURE BAKER GRADE UNKNOWN". DEVICE HAS BEEN EXPLANTED AND REPLACED.
Patient problems: Capsular Contracture
MAUDE report 22907638 ↗InjuryJul 11, 2025Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
HEALTHCARE PROFESSIONAL REPORTED "CAPSULAR CONTRACTURE BAKER GRADE III¿. THIS RECORD IS FOR THE RIGHT SIDE. DEVICE WAS EXPLANTED.
Patient problems: Capsular Contracture
MAUDE report 22484548 ↗InjuryMar 26, 2025Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
HEALTHCARE PROFESSIONAL REPORTED RIGHT SIDE CAPSULAR CONTRACTURE BAKER GRADE III. DEVICE WAS EXPLANTED AND REPLACED.
Patient problems: Capsular Contracture
MAUDE report 21700631 ↗InjuryJan 18, 2024Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
HEALTHCARE PROFESSIONAL REPORTED VIA NBIR A LEFT SIDE CAPSULAR CONTRACTURE BAKER GRADE III. DEVICE HAS BEEN EXPLANTED AND REPLACED.
Patient problems: Capsular Contracture
MAUDE report 18540066 ↗InjuryJan 18, 2024Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
HEALTHCARE PROFESSIONAL REPORTED VIA NBIR A RIGHT SIDE CAPSULAR CONTRACTURE BAKER GRADE IV. DEVICE HAS BEEN EXPLANTED AND REPLACED.
Patient problems: Capsular Contracture
MAUDE report 18540061 ↗InjuryOct 23, 2023Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
HEALTHCARE PROFESSIONAL REPORTED A LEFT SIDE CAPSULAR CONTRACTURE BAKER GRADE III. DEVICE HAS BEEN EXPLANTED.
Patient problems: Capsular Contracture
MAUDE report 17991290 ↗InjuryAug 15, 2023Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
HEALTHCARE PROFESSIONAL REPORTED LEFT SIDE CAPSULAR CONTRACTURE, BAKER GRADE IV. DEVICE HAS BEEN EXPLANTED AND REPLACED.
Patient problems: Capsular Contracture
MAUDE report 17548433 ↗InjuryMay 11, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
HEALTHCARE PROFESSIONAL REPORTED WOUND DEHISCENCE FOR RIGHT SIDE. DEVICE EXPLANTED AND REPLACED.
Patient problems: Wound Dehiscence
MAUDE report 16916305 ↗InjuryMar 15, 2023Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
InjuryFeb 16, 2023Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
HEALTHCARE PROFESSIONAL REPORTED VIA NBIR LEFT SIDE CAPSULAR CONTRACTURE BAKER GRADE IV AND RUPTURE. DEVICE HAS BEEN EXPLANTED.
Patient problems: Capsular Contracture
MAUDE report 16392088 ↗InjuryJan 18, 2023Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
HEALTHCARE PROFESSIONAL REPORTED RIGHT SIDE CAPSULAR CONTRACTURE BAKER GRADE III/IV. DEVICE HAS BEEN EXPLANTED.
Patient problems: Capsular Contracture
MAUDE report 16194618 ↗InjuryDec 20, 2022Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
HEALTHCARE PROFESSIONAL REPORTED LEFT SIDE CAPSULAR CONTRACTURE, BAKER GRADE III. DEVICE REMAINS IMPLANTED.
Patient problems: Capsular Contracture
MAUDE report 16017889 ↗InjuryNov 30, 2022Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
HEALTHCARE PROFESSIONAL REPORTED A LEFT-SIDE CAPSULAR CONTRACTURE, BAKER GRADE IV. DEVICE REMAINS IMPLANTED.
Patient problems: Capsular Contracture
MAUDE report 15890001 ↗InjuryNov 29, 2022Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
PATIENT REPORT LEFT SIDE "PAIN", "LOST SHAPE", "BECAME HARD", AND "CAPSULAR CONTRACTURE". HEALTHCARE PROFESSIONAL REPORTED CAPSULAR CONTRACTURE BAKER GRADE III/IV. DEVICE REMAINS IMPLANTED.
Patient problems: Capsular Contracture
MAUDE report 15882364 ↗InjuryNov 22, 2022Device Appears to Trigger Rejection; Material Rupture; Device Appears to Trigger Rejection; Material Rupture
HEALTHCARE PROFESSIONAL REPORTED A LEFT-SIDE RUPTURE. DEVICE REMAINS IMPLANTED.
Patient problems: Capsular Contracture; Failure of Implant
MAUDE report 15848854 ↗InjuryNov 15, 2022Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
HEALTHCARE PROFESSIONAL REPORTED LEFT SIDE CAPSULAR CONTRACTURE BAKER GRADE UNKNOWN. DEVICE HAS BEEN EXPLANTED AND REPLACED.
Patient problems: Capsular Contracture
MAUDE report 15798834 ↗InjuryNov 15, 2022Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
HEALTHCARE PROFESSIONAL REPORTED RIGHT SIDE CAPSULAR CONTRACTURE BAKER GRADE UNKNOWN. DEVICE HAS BEEN EXPLANTED AND REPLACED.
Patient problems: Failure of Implant
MAUDE report 15798732 ↗InjuryOct 25, 2022Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
HEALTHCARE PROFESSIONAL REPORTED LEFT SIDE CAPSULAR CONTRACTURE, BAKER GRADE III/IV. THE DEVICE REMAINS IMPLANTED.
Patient problems: Capsular Contracture
MAUDE report 15666440 ↗InjuryOct 4, 2022Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
HEALTHCARE PROFESSIONAL REPORTED "CAPSULAR CONTRACTURE" BAKER GRADE UNKNOWN AGAINST LEFT DEVICE. THE DEVICE HAS BEEN EXPLANTED.
Patient problems: Capsular Contracture
MAUDE report 15541076 ↗InjurySep 22, 2022Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
HEALTHCARE REPORTED LEFT SIDE CAPSULAR CONTRACTURE BAKER GRADE III/IV. DEVICE REMAINS IMPLANTED.
Patient problems: Capsular Contracture
MAUDE report 15465039 ↗InjurySep 22, 2022Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
HEALTHCARE REPORTED RIGHT SIDE CAPSULAR CONTRACTURE BAKER GRADE III/IV. DEVICE REMAINS IMPLANTED.
Patient problems: Capsular Contracture
MAUDE report 15464932 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P020056. One submission often covers many models, so check the product and lot details in each record.
- Z-0700-2020 · Nov 6, 2019 · TerminatedNatrelle Silicone Filled Breast Implants for the following Styles and Sizes: Style 10, Style 15, Style 20, Style 40, Style 45 Style 10/UDI: NATRELLE Style 10-180 Gel Round Mod
- Z-0701-2020 · Nov 6, 2019 · TerminatedNatrelle Inspira Sillicone-Filled Breast Implants for the following Styles and Sizes: 7607 SSM, 7608 SSF, 7609 SSX, 7513 SRL, 7514 SRLP, 7515 SRM, 7516 SRF, 7517 SRX, 7626 SCL, 762
- Z-2453-2019 · Jul 24, 2019 · Open, ClassifiedNatrelle Inspira, Silicone-Filled Breast Implants, Sterile, for the following style numbers: Style TRL: TRL-110TRL-125,TRL-140,TRL-170,TRL-200,TRL-230,TRL-260,TRL-290,TRL-320,TR
- Z-2454-2019 · Jul 24, 2019 · Open, ClassifiedNatrelle and McGhan Silicone-Filled Breast Implant BioCell Round Moderate Profile, Sterile, for the following style numbers: Style 110:110-090, 110-120, 110-150, 110-180, 110-
Other Prosthesis, Breast, Noninflatable, Internal, Silicone Gel-Filled devices
- MENTOR MemoryGel Breast Implant 3503501BCMentor Texas L.P. · Prosthesis, breast, noninflatable, internal, silicone gel-filled2,167 reports
- MENTOR MemoryGel Breast Implant 3504001BCMentor Texas L.P. · Prosthesis, breast, noninflatable, internal, silicone gel-filled2,130 reports
- MENTOR MemoryGel Breast Implant 3504004BCMentor Texas L.P. · Prosthesis, breast, noninflatable, internal, silicone gel-filled2,012 reports
- MENTOR MemoryGel Breast Implant 3504504BCMentor Texas L.P. · Prosthesis, breast, noninflatable, internal, silicone gel-filled1,754 reports
- MENTOR MemoryGel Breast Implant 3503001BCMentor Texas L.P. · Prosthesis, breast, noninflatable, internal, silicone gel-filled1,752 reports
- MENTOR MemoryGel Breast Implant 3503504BCMentor Texas L.P. · Prosthesis, breast, noninflatable, internal, silicone gel-filled1,749 reports
- MENTOR MemoryGel Breast Implant 3504501BCMentor Texas L.P. · Prosthesis, breast, noninflatable, internal, silicone gel-filled1,690 reports
- MENTOR MemoryGel Breast Implant 3503251BCMentor Texas L.P. · Prosthesis, breast, noninflatable, internal, silicone gel-filled1,684 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.