CHESAPEAKE® Stabilization System 2001-15525Recalls & reported problems
VB Spine LLC · Screw Size Ø5.5x25 mm · Class 2 · Implant
All models of CHESAPEAKE Stabilization System (30)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10888857025417), received between Mar 2, 2022 and Mar 2, 2022 — classified as 1 malfunction.
The most frequently reported specific device problem is “Mechanical Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Mechanical Problem1
- Unintended Ejection1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 2, 2022Unintended Ejection; Mechanical Problem; Unintended Ejection; Mechanical Problem
IT WAS REPORTED THAT DURING A CHESAPEAKE LUMBER CASE, THE UNIVERSAL AWL 'SKIVED' OFF THE ENDPLATE AND DID NOT CREATE THE NECESSARY PILOT HOLE FOR THE SCREW. THIS RESULTED IN THE CAGES AT S1 AND L4 HAVING ONLY 2 SCREWS INSERTED INSTEAD OF 3. ADDITIONALLY, DURING SCREW INSERTION, THE ANGLED TAPERED DRIVER CAME OFF OF THE SCREW. IT WAS ALSO OBSERVED THAT THE LASER MARKINGS HAD WORN OFF OF THE EXPANDABLE DRILL GUIDE. THIS REPORT WILL CAPTURE THE SCREW.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13655680 ↗
FDA clearance and classification
The FDA regulates product code MQP (spinal vertebral body replacement device) under 21 CFR 888.3060 as a Class II device. 21 CFR 888.3060 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the CHESAPEAKE® Stabilization System 2001-15525
Has the CHESAPEAKE® Stabilization System 2001-15525 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10888857025417), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the CHESAPEAKE® Stabilization System 2001-15525?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Mar 2, 2022. That report lists device problems “Mechanical Problem” (1) and “Unintended Ejection” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the CHESAPEAKE® Stabilization System 2001-15525?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the CHESAPEAKE® Stabilization System 2001-15525 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the CHESAPEAKE® Stabilization System 2001-15525, and is it still sold?
The FDA's device database lists VB Spine LLC as the company responsible for it (brand CHESAPEAKE® Stabilization System, model 2001-15525). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other SPINAL VERTEBRAL BODY REPLACEMENT DEVICE devices
- GIZA Corpectomy implant Giza, Diam 14 mm, 18-22 mm, 2-5 DegEden Spine Europe SA · Spinal Vertebral Body Replacement Device1 recall0 reports
- X-CORE 7220018Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- GIZA Corpectomy implant Giza, Diam 14 mm, 33-54 mm, 7-10 DegEden Spine Europe SA · Spinal Vertebral Body Replacement Device1 recall0 reports
- GIZA Corpectomy implant Giza, Diam 14 mm, 18-22 mm, 5-8 DegEden Spine Europe SA · Spinal Vertebral Body Replacement Device1 recall0 reports
- GIZA Corpectomy implant Giza, Diam 14 mm, 23-32 mm, 7-10 DegEden Spine Europe SA · Spinal Vertebral Body Replacement Device1 recall0 reports
- X-CORE 7220016Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- X-CORE 7180016Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- GIZA Corpectomy implant Giza, Diam 14 mm, 23-32 mm, 2-5 DegEden Spine Europe SA · Spinal Vertebral Body Replacement Device1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page