Skip to content

OZARK Cervical Plate System 8801-14016DARecalls & reported problems

VB Spine LLC · Fixed Screw, Self-Starting Size Ø4.0x16 mm · Class 2 · Implant

All models of OZARK Cervical Plate System (54)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10888857392366), received between Feb 17, 2021 and May 8, 2024 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Fracture” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 2 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture4
  • Migration2

Patient problems

  • No Clinical Signs, Symptoms or Conditions4

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 8, 2024Fracture; Migration; Fracture; Migration

    IT WAS REPORTED THAT TWO OZARK SELF-STARTING SCREWS AT C6 HAVE FRACTURED AND THE LOCKING MECHANISM OF AN OZARK PLATE AT THAT SAME LEVEL HAS DISENGAGED. THE PATIENT IS ASYMPTOMATIC AND REVISION SURGERY IS NOT PLANNED. THIS REPORT CAPTURES THE FIRST OF THE TWO OZARK SCREWS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19274361 ↗
  • MalfunctionMay 8, 2024Fracture; Migration; Fracture; Migration

    IT WAS REPORTED THAT TWO OZARK SELF-STARTING SCREWS AT C6 HAVE FRACTURED AND THE LOCKING MECHANISM OF AN OZARK PLATE AT THAT SAME LEVEL HAS DISENGAGED. THE PATIENT IS ASYMPTOMATIC AND REVISION SURGERY IS NOT PLANNED. THIS REPORT CAPTURES THE SECOND OF THE TWO OZARK SCREWS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19274358 ↗
  • MalfunctionFeb 17, 2021Fracture

    IT WAS REPORTED THAT TWO OZARK FIXED SCREWS AT C6 FRACTURED APPROXIMATELY 6 MONTHS POST-OPERATIVELY. REVISION SURGERY HAS NOT BEEN SCHEDULED NOR PERFORMED AT THIS TIME. THIS REPORT CAPTURES THE FIRST OF THE TWO OZARK SCREWS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11340016 ↗
  • MalfunctionFeb 17, 2021Fracture

    IT WAS REPORTED THAT TWO OZARK FIXED SCREWS AT C6 FRACTURED APPROXIMATELY 6 MONTHS POST-OPERATIVELY. REVISION SURGERY HAS NOT BEEN SCHEDULED NOR PERFORMED AT THIS TIME. THIS REPORT CAPTURES THE SECOND OF THE TWO OZARK SCREWS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11340004 ↗

Other Appliance, fixation, spinal intervertebral body devices

All Appliance, fixation, spinal intervertebral body devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page