OsteoSurge 300 Putty 56500100Recalls & reported problems
Isotis Orthobiologics, Inc. · OsteoSurge300 Putty, 10cc - demineralized human bone mixed with poloxamer resorbable reverse phase medium. OsteoSurge300 is formulated into a putty form and is provided in a sterile, single use package. · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10889981055851), received between Jul 29, 2016 and Jul 29, 2016 — classified as 1 injury.
The most frequently reported specific device problem is “Patient-Device Incompatibility” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Patient-Device Incompatibility1
Patient problems
- Neurological Deficit/Dysfunction1
- Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJul 29, 2016Patient-Device Incompatibility; Patient-Device Incompatibility
INITIAL PLF SURGERY ON (B)(6) 2016 TO ADDRESS LEFT LEG PAIN, INVOLVED DIRECT DECOMPRESSION OF THE THECAL SAC, PLACEMENT OF GLOBUS PEDICLE SCREW SYSTEM CONSTRUCT FROM L4 TO S1, AND POSTEROLATERAL GUTTER FUSION CONSISTING OF BMAC (BONE MARROW ASPIRATE CONCENTRATE) MIXED WITH HEPARIN AND BONE VOID FILLER PUTTY PLACED IN THE LATERAL GUTTERS. PATIENT WAS ASYMPTOMATIC AND WALKING IMMEDIATE POST-OPERATIVELY. EVENT: THIRD DAY POST-OPERATIVELY THE PATIENT HAD PAIN AND NUMBNESS IN THE RIGHT LEG. UPON EVALUATION OF THE MRI IT WAS DETERMINED THAT THE THECAL SAC WAS COMPRESSED BY A POSSIBLE HEMATOMA/ SEROMA (POSSIBLE CAUSE OF THE NEUROLOGICAL DEFICIT.) DURING REVISION, NO HEMATOMA WAS FOUND, BUT INFLAMMATION OF THE AREA WAS OBSERVED AND GRAFT WAS OBSERVED TO HAVE A GELATIN CONSISTENCY AND NEAR THE NERVE. REVISION WAS PERFORMED REMOVING 50% OF THE POSTEROLATERAL FUSION MATERIAL NEAR THE THECAL SAC. ON THE FIFTH DAY AN ADDITIONAL MRI SCAN WAS PERFORMED AND IT DEPICTED A REOCCURRING SEROMA IN THE SAME AREA. PATIENT OUTCOME: PATIENT CURRENT HAVING LEG PAIN IN BOTH LEGS AND NUMBNESS IN THE FEET, POST REVISION. SURGEON IS EVALUATING PATIENT AND A SECOND REVISION WAS PLANNED FOR (B)(6) 2016.
Patient problems: Neurological Deficit/Dysfunction; Pain
MAUDE report 5835393 ↗
Other FILLER, BONE VOID, CALCIUM COMPOUND devices
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T44150Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND3 recalls1 report
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T42275Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND2 recalls1 report
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T42280Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND2 recalls0 reports
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T42200Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND2 recalls0 reports
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T44145Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND2 recalls0 reports
- MAGNIFUSE® Bone Graft 7509014Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND1 recall2 reports
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T43102Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND1 recall2 reports
- HydroSet XT 897005Stryker Corporation · FILLER, BONE VOID, CALCIUM COMPOUND1 recall1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page