Lixelle S-25Recalls & reported problems

Kaneka Corporation · The Lixelle(r) beta 2-microglobulin apheresis column is indicated for the treatment of patients with clinically-diagnosed dialysis-related amyloidosis (DRA). · Class f

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 14993478020225), received between Mar 14, 2019 and Oct 17, 2025 — classified as 3 injuries.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 2 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3

Patient problems

  • Low Blood Pressure/ Hypotension2
  • Vomiting2
  • Anemia1
  • Dyspnea1
  • Fatigue1
  • Fever1
  • Loss of consciousness1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 17, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT HAD BEEN RECEIVING LIXELLE S-15 THERAPY SINCE (B)(6) 2025 FOR IMPROVEMENT OF DIALYSIS-RELATED AMYLOIDOSIS SYMPTOMS. TREATMENT WAS PAUSED FOR ONE MONTH IN AUGUST AND RESTARTED IN EARLY (B)(6). ON (B)(6) 2025, APPROXIMATELY 50 MINUTES AFTER RESUMING DIALYSIS WITH LIXELLE, THE PATIENT COMPLAINED OF PALPITATIONS AND FEELING UNWELL, FOLLOWED BY SUDDEN LOSS OF CONSCIOUSNESS AND VOMITING. BLOOD PRESSURE DROPPED FROM 160 MMHG TO 100 MMHG. EMERGENCY INTERVENTION WAS PERFORMED, INCLUDING IMMEDIATE CESSATION OF TREATMENT AND CHEST COMPRESSIONS, WHICH SUCCESSFULLY RESTORED CONSCIOUSNESS. NO HOSPITALIZATION WAS REQUIRED. ON (B)(6) 2025, DIALYSIS WAS PERFORMED WITHOUT LIXELLE AND WAS UNEVENTFUL. THE PATIENT HAS REMAINED STABLE ON I-HDF THERAPY SINCE THEN. THE EVENT WAS **CONSIDERED LIFE-THREATENING** AND REQUIRED INTERVENTION TO PREVENT PERMANENT IMPAIRMENT. MFR REPORT #: 3002808904-2025-00034.

    Patient problems: Loss of consciousness; Low Blood Pressure/ Hypotension; Vomiting

    MAUDE report 23324356 ↗
  • InjuryOct 17, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT, AN 81-YEAR-OLD FEMALE WITH A HISTORY OF LONG-TERM HEMODIALYSIS, STARTED TREATMENT WITH LIXELLE S-25 ON (B)(6) 2025 FOR DIALYSIS-RELATED AMYLOIDOSIS. ON (B)(6) 2025, HEMOGLOBIN DECREASED TO 6.7 G/DL (PREVIOUS VALUE IN JULY: 13.8 G/DL WITHOUT ESA). THE PATIENT WAS HOSPITALIZED FROM (B)(6) 2025 PRIMARILY FOR BLOOD TRANSFUSION THERAPY AND MONITORING. RBC TRANSFUSIONS WERE ADMINISTERED (2 UNITS ON 08-29 AND 2 UNITS ON 08-30), AND DARBEPOETIN (10 MCG WEEKLY) WAS INITIATED. CONSIDERING THE PATIENT'S PREFERENCE, FURTHER APPLICATION OF LIXELLE IN SUBSEQUENT DIALYSIS SESSIONS WAS DISCONTINUED. HEMOGLOBIN IMPROVED TO 10.7 G/DL BY (B)(6) 2025. THE PHYSICIAN INDICATED A POSSIBLE RELATIONSHIP BETWEEN THE DEVICE AND THE EVENT; RELATIONSHIPS WITH OTHER DEVICES OR DRUGS WERE NOT CONFIRMED. MFR REPORT #: 3002808904-2025-00033.

    Patient problems: Anemia; Fatigue

    MAUDE report 23324328 ↗
  • InjuryMar 14, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    LIXELLE S-15 TREATMENT DURING HEMODIALYSIS (HD) WAS INTRODUCED ON (B)(6) 2017 WITHOUT PROBLEMS. LIXELLE S-25, A LARGER SIZE LIXELLE, STARTED TO USE INSTEAD OF S-15 ON (B)(6) 2017 AND WAS USED SUCCESSFULLY. THE PATIENT WAS TRANSFERRED TO ANOTHER HOSPITAL FOR ABLATION ON (B)(6) 2018 AND STARTED ADMINISTRATION OF WARFARIN. THE FIRST HD WITHOUT LIXELLE AFTER DISCHARGE ON (B)(6) 2018 WAS PERFORMED. ALTHOUGH THE PATIENT FELT A LITTLE SICK, HOWEVER HE COMPLETED THE HD TO THE END. THE HD WITH LIXELLE S-25 WAS RESUMED ON (B)(6) 2018. THE BLOOD PRESSURE (BP) AT THE START OF TREATMENT WAS ABOUT 150 MMHG BUT DROPPED TO ABOUT 90 MMHG. WHEEZING, BREATHING DIFFICULTY AND PALLOR OF THE FACE WERE OBSERVED. SINCE SPO2 WAS 93%, OXYGEN INHALATION WAS STARTED AT 2 L, HOWEVER THE PATIENT CAUSED NAUSEA AND VOMITING. IT WAS DECIDED THAT THE TREATMENT WAS DISCONTINUED IN 40 MINUTES FROM THE START. HD WITH LIXELLE S-25 WAS CONDUCTED AGAIN ON (B)(6) 2018. THE PATIENT HAD A FEVER OF 38 DEGREES AT THE START. FLU TEST WAS NEGATIVE. AFTER TAKING ANTIPYRETICS, THE TREATMENT WAS STARTED. THE BLOOD PRESSURE WAS 120 MMHG AT THE START OF TREATMENT. ONE HOUR LATER, HE COMPLAINED OF ABDOMINAL DISCOMFORT. ALTHOUGH THE B

    Patient problems: Dyspnea; Fever; Low Blood Pressure/ Hypotension; Vomiting

    MAUDE report 8423409 ↗