Portex Z210-14Recalls & reported problems

Icu Medical, Inc. · Class 1

Adverse event reports
10
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 15019315046902), received between Jun 4, 2018 and Sep 2, 2025 — classified as 3 injuries, 7 malfunctions.

The most frequently reported specific device problem is “Suction Problem” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Suction Problem3
  • Difficult to Insert2
  • Backflow1
  • Break1
  • Decrease in Suction1
  • Infusion or Flow Problem1
  • Stretched1
  • Use of Device Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions7
  • Pneumothorax2
  • Low Oxygen Saturation1

Recent adverse event reports

The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.

  • InjurySep 2, 2025Use of Device Problem; Suction Problem; Use of Device Problem; Suction Problem

    IT WAS REPORTED THAT THE PATIENT'S OXYGEN SATURATION WAS LOW, AND THEY HAD THICK MUCUS/PHLEGM THAT NEEDED TO BE SANCTIONED, BUT THE INLINE CATHETER WAS ONLY ABLE TO MOVE ABOUT 1 INCH (WHERE LUMENS ATTACH TO T-PIECE CONNECTOR), AND THE PATIENT CONTINUED TO DESATURATE DUE TO THIS ISSUE. REPORTER STATED A NEW INLINE SUCTION CATHETER WAS USED AND ABLE TO CLEAR THE SPUTUM. THE PATIENT'S OXYGEN SATURATION STABILIZED AFTER.

    Patient problems: Low Oxygen Saturation

    MAUDE report 22938968 ↗
  • MalfunctionSep 4, 2022Suction Problem; Suction Problem

    IT WAS REPORTED THAT THE SUCTION DOES NOT COUPLED IN TQT OR TOT WITH LEAKAGE. NO PATIENT INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15353918 ↗
  • MalfunctionSep 4, 2022Break; Break

    IT WAS REPORTED THAT THE CLOSE VENTILATION SUCTION SYSTEMS BROKE AT THE WHITE RING SEVERAL TIMES. IT WAS FURTHER REPORTED THAT THE BLUE CONTROL VALVE OF THE SYSTEMS BROKE AND NOT THE WHITE RING. NO PATIENT INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15353841 ↗
  • MalfunctionSep 4, 2022Difficult to Insert; Difficult to Insert

    IT WAS REPORTED THAT IT WAS DIFFICULT TO INTRODUCE THE BIOPSY DEVICE DURING AN ALVEOLAR BIOPSY ON A PATIENT WHO WAS INTUBATED THE NIGHT BEFORE. IT WAS ALSO DIFFICULT TO RINSE WHEN NECESSARY. NO PATIENT INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15353839 ↗
  • MalfunctionSep 4, 2022Infusion or Flow Problem; Infusion or Flow Problem

    IT WAS REPORTED THAT THE VOLUME WAS NOT DELIVERED DURING ASPIRATION AND ESPECIALLY DURING THE TIME OF FLUSHING OF THE TUBING VERY DIFFICULT. NO PATIENT INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15353835 ↗
  • MalfunctionSep 4, 2022Difficult to Insert; Difficult to Insert

    IT WAS REPORTED THAT IT WAS DIFFICULT TO INTRODUCE THE BIOPSY DEVICE DURING AN ALVEOLAR BIOPSY ON A PATIENT WHO WAS INTUBATED THE NIGHT BEFORE. IT WAS ALSO DIFFICULT TO RINSE WHEN NECESSARY NO PATIENT INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15353834 ↗
  • MalfunctionSep 4, 2022Stretched; Stretched

    IT WAS REPORTED THAT UPON THE USE OF THE PRODUCT, THE CUSTOMER NOTICED THE SLEEVE WAS EXPANDING BEFORE PERFORMING SUCTION. NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15353831 ↗
  • MalfunctionJun 10, 2021Backflow; Backflow

    INFORMATION RECEIVED A SMITHS MEDICAL SUCTIONPRO72 DL 14 20/CA SUCTION/PORTEX CATHETERS SUCTIONPRO 72 REPORT INDICATED WATER REMAINED IN THE DEVICE AND CREATED ALARM WITH THE VENTILATOR. THE DRIPPED DROPLET FROM THE END OF THE RING CONNECTOR, FACILITATED UNTIMELY DISASSEMBLY OF THE COUPLING (THE COUPLING IS NO LONGER CONNECTED AT ONE OF ITS ENDS) : THE VENTILATION CIRCUIT WAS OPEN. CONCERN FOR DECANNULATION OF VENTILATOR AND CONTAMINATION OF DROPLETS. REPORTED NO PATIENT INJURY OCCURRED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11974527 ↗
  • InjuryJun 13, 2018Suction Problem; Suction Problem

    INFORMATION WAS RECEIVED INDICATING THAT A SMITHS MEDICAL PORTEX® SUCTIONPRO 72¿ SUCTIONED INEFFECTIVELY FOLLOWING 6 - 8 HOURS OF USE. SUBSEQUENTLY, IT WAS REPORTED THAT THE PATIENT'S LUNG COLLAPSED; LEADING TO A REQUIRED BRONCHOSCOPY BEING PERFORMED. THERE WERE NO FURTHER REPORTED ADVERSE EFFECTS.

    Patient problems: Pneumothorax

    MAUDE report 7598821 ↗
  • InjuryJun 4, 2018Decrease in Suction; Decrease in Suction

    INFORMATION WAS RECEIVED INDICATING THAT THIS CLOSED VENTILATION SUCTION SYSTEM DID NOT SUCTION EFFICIENTLY. THIS WAS DISCOVERED ABOUT 6-8 MINUTES AFTER USE. THE PATIENT SUFFERED A LUNG COLLAPSE AND REQUIRED BRONCHOSCOPY. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Pneumothorax

    MAUDE report 7567173 ↗

Other CATHETERS, SUCTION, TRACHEOBRONCHIAL devices

All CATHETERS, SUCTION, TRACHEOBRONCHIAL devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.