Portex 100/899/070CZRecalls & reported problems
Icu Medical, Inc. · Class 2
All models of Portex (409)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 15019315107221), received between Mar 16, 2020 and Aug 1, 2025 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Device Dislodged or Dislocated2
- Defective Component1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- No Consequences Or Impact To Patient1
- No Patient Involvement1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 1, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT A PATIENT HAD A TRACHEOSTOMY PUT IN PLACE APPROXIMATELY OVER THREE (3) AND A HALF WEEKS AGO COUNTING FROM (B)(6) 2025. DUE TO THE CLIP FAILING A NEW ONE WAS PUT IN PLACE. THE CLIP HELD IN PLACE WITH NO ISSUES FOR A WEEK AND A HALF BUT THEN STARTED TO SLIP CAUSING THE TRACHEOSTOMY TO COME OUT OF PLACE. THE REPORTER STATED THEY NEEDED TO CHANGE THE TUBE AND INSERT A NEW ONE. THERE WAS PATIENT INVOLVEMENT, AND NO ADVERSE HARM REPORTED. THE SECOND EVENT IS DOCUMENTED ON EMDR-72501
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22686608 ↗MalfunctionAug 1, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT A PATIENT HAD A TRACHEOSTOMY PUT IN PLACE APPROXIMATELY OVER THREE (3) AND A HALF WEEKS AGO COUNTING FROM (B)(6) 2025. DUE TO THE CLIP FAILING A NEW ONE WAS PUT IN PLACE. THE CLIP HELD IN PLACE WITH NO ISSUES FOR A WEEK AND A HALF BUT THEN STARTED TO SLIP CAUSING THE TRACHEOSTOMY TO COME OUT OF PLACE. THE REPORTER STATED THEY NEEDED TO CHANGE THE TUBE AND INSERT A NEW ONE. THERE WAS PATIENT INVOLVEMENT, AND NO ADVERSE HARM REPORTED. THE SECOND EVENT IS DOCUMENTED ON EMDR-73306.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22686514 ↗MalfunctionMar 16, 2020Defective Component; Defective Component
INFORMATION WAS RECEIVED THAT THE BLUE LOCKSYSTEM ON A SMITHS MEDICAL REGARDING A PORTEX UNIPERC INNER CANNULA DID NOT WORK. NO ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: No Consequences Or Impact To Patient; No Patient Involvement
MAUDE report 9833561 ↗
Other Tube, tracheostomy (w/wo connector) devices
- Portex 101/860/080CZIcu Medical, Inc. · Tube, tracheostomy (w/wo connector)188 reports
- Portex 101/860/075CZIcu Medical, Inc. · Tube, tracheostomy (w/wo connector)115 reports
- Bivona 60SP040Icu Medical, Inc. · Tube, tracheostomy (w/wo connector)1 recall20 reports
- Bivona 60SP050Icu Medical, Inc. · Tube, tracheostomy (w/wo connector)1 recall13 reports
- Bivona 60P040Icu Medical, Inc. · Tube, tracheostomy (w/wo connector)1 recall12 reports
- Portex 101/860/070CZIcu Medical, Inc. · Tube, tracheostomy (w/wo connector)60 reports
- Bivona 60SP045Icu Medical, Inc. · Tube, tracheostomy (w/wo connector)1 recall8 reports
- Bivona 60SN040Icu Medical, Inc. · Tube, tracheostomy (w/wo connector)1 recall5 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page