Jelco 405011Recalls & reported problems

Icu Medical, Inc. · Class 2

All models of Jelco (101)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 15019315118333), received between Mar 24, 2022 and May 11, 2026 — classified as 2 injuries, 3 malfunctions.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 3 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1
  • Defective Component1
  • Detachment of Device or Device Component1
  • Difficult to Remove1
  • Material Separation1
  • Material Too Soft/Flexible1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Insufficient Information1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 11, 2026Detachment of Device or Device Component

    IT WAS REPORTED THAT THEY PLACED 22 GAUGE IV IN THE LEFT FOOT. THE LINE WOULD NOT FLUSH SO THEY DECIDED TO REMOVE THE CATHETER WHILE CONTINUING TO LOOK FOR IV ACCESS ON THE OTHER LIMBS. AS THEY REMOVED THE CATHETER, THEY HEARD A POP AND INSPECTED THE REMAINING PIECE OF THE CATHETER AS IT LOOKED SHORT. THEY LOOKED AT THE SITE AND DID NOT SEE ANY OF THE REMAINING PIECE OF THE CATHETER AT THE INSERTION SITE, ON THE BED OR ON THE NEARBY 4X4S. WHILE WAITING FOR GENERAL SURGERY, THEY DID THE ENT PORTION OF THE CASE AND ALSO LOOKED AT THE INSERTION SITE WITH THE ULTRASOUND. ALL PARTS OF THE FOREIGN BODY OF THE CATHETER WERE REMOVED AND INTACT. THERE WAS A DELAY OF THERAPY. PROLONGED ANESTHESIA DUE TO SURGICAL REMOVAL OF RETAINED PIECE OF CATHETER. THERE WAS A PATIENT INVOLVEMENT AND THERE WAS A PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25135398 ↗
  • MalfunctionMay 8, 2026Material Separation; Defective Component

    IT WAS REPORTED THAT THEY NOTICED THE CATHETER SHEARED AWAY FROM THE NEEDLE DURING REMOVAL/END OF THERAPY. THERE WAS A MEDICAL INTERVENTION REQUIRED. THIS DAMAGE COULD CAUSE HARM TO THE PATIENT. THERE WAS NO PATIENT INVOLVEMENT AND THERE WAS NO PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25125077 ↗
  • MalfunctionMay 8, 2026Difficult to Remove

    IT WAS REPORTED THAT THE CATHETER WAS UNABLE TO REMOVE, IT WAS STUCK. AFTER REMOVAL, THEY NOTICED THE CATHETER TIP WAS MISSING. MEDICAL INTERVENTION WAS REQUIRED. THE REPORTED ISSUE COULD CAUSE SERIOUS HARM TO THE PATIENT. THERE WAS A PATIENT INVOLVEMENT AND THERE WAS A PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25125054 ↗
  • InjuryAug 22, 2025Break; Break

    IT WAS REPORTED THAT THE PERIPHERAL INTRAVENOUS LINE WAS ATTEMPTED IN THE LEFT AC AND, WHEN THE CATHETER WAS PULLED OUT, THE TIP WAS FOUND TO BE SHEARED OFF. PER REPORTER, AN X-RAY WAS DONE, AND THE PORTION OF THE DEVICE WAS SEEN ON THE X-RAY.

    Patient problems: Insufficient Information

    MAUDE report 22872607 ↗
  • MalfunctionMar 24, 2022Material Too Soft/Flexible; Material Too Soft/Flexible

    IT WAS REPORTED THAT THE PLASTIC PORTION OF THE CATHETER, THE THIN TUBE THAT SHOULD BE INSERTED INTO THE PATIENT, CRUMBLES AND BENDS/KINKS; MAKING IT VERY DIFFICULT TO CANNULATE` PATIENT. NO PATIENT INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13894843 ↗

Other Catheter,intravascular,therapeutic,short-term less than 30 days devices

All Catheter,intravascular,therapeutic,short-term less than 30 days devices →