LMA AIRWAY MANAGEMENT IPN922891Recalls & reported problems

Teleflex Incorporated · LMA ProSeal™ Size 4 · Class 1

All models of LMA AIRWAY MANAGEMENT (47)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 15060112318730), received between Nov 23, 2022 and Feb 14, 2023 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Manufacturing, Packaging or Shipping Problem” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Manufacturing, Packaging or Shipping Problem3
  • Break1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • Insufficient Information1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 14, 2023Break; Break

    REPORTED EVENT: 15MM CONNECTOR OF LMA PROSEAL #4 SNAPPED OFF WHEN THE DOCTOR TRIED TO CONNECT TO CIRCUIT WITHOUT MUCH FORCE. THE DEVICE WAS USED ONLY 20 TIMES. THERE WAS NO REPORTED INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16373540 ↗
  • MalfunctionNov 23, 2022Manufacturing, Packaging or Shipping Problem; Manufacturing, Packaging or Shipping Problem

    IT WAS REPORTED THAT "THE RED CAP OF THE MANUAL VENT IS MISSING" WHILE IN USE ON PATIENT. FURTHER INFORMATION STATES THAT THERE WERE NO ISSUES WITH DEFLATION/INFLATION OF THE CUFF DURING USE AND THAT THIS WAS A RE-STERILIZED DEVICE. AN INFLATION/DEFLATION TEST OCCURRED PRIOR TO USE HOWEVER THE MISSING CAP WAS NOT NOTED. PATIENT STATUS REPORTED AS "FINE". ASSOCIATED MDRS: 9681900-2022-00031 AND 9681900-2022-00033.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15852675 ↗
  • MalfunctionNov 23, 2022Manufacturing, Packaging or Shipping Problem; Manufacturing, Packaging or Shipping Problem

    IT WAS REPORTED THAT "THE RED CAP OF THE MANUAL VENT IS MISSING" WHILE IN USE ON PATIENT. FURTHER INFORMATION STATES THAT THERE WERE NO ISSUES WITH DEFLATION/INFLATION OF THE CUFF DURING USE AND THAT THIS WAS A RE-STERILIZED DEVICE. AN INFLATION/DEFLATION TEST OCCURRED PRIOR TO USE HOWEVER THE MISSING CAP WAS NOT NOTED. PATIENT STATUS REPORTED AS "FINE". SEE ASSOCIATED MDRS 9681900-2022-00032 AND 9681900-2022-00033.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15852634 ↗
  • MalfunctionNov 23, 2022Manufacturing, Packaging or Shipping Problem; Manufacturing, Packaging or Shipping Problem

    IT WAS REPORTED THAT "THE RED CAP OF THE MANUAL VENT IS MISSING" WHILE IN USE ON PATIENT. FURTHER INFORMATION STATES THAT THERE WERE NO ISSUES WITH DEFLATION/INFLATION OF THE CUFF DURING USE AND THAT THIS WAS A RE-STERILIZED DEVICE. AN INFLATION/DEFLATION TEST OCCURRED PRIOR TO USE HOWEVER THE MISSING CAP WAS NOT NOTED. PATIENT STATUS REPORTED AS "FINE". SEE ASSOCIATED MDRS 9681900-2022-00031 AND 9681900-2022-00032.

    Patient problems: Insufficient Information

    MAUDE report 15852542 ↗

Other AIRWAY, OROPHARYNGEAL, ANESTHESIOLOGY devices

All AIRWAY, OROPHARYNGEAL, ANESTHESIOLOGY devices →