Access CK-MB 386371Recalls & reported problems
Beckman Coulter, Inc. · The Access CK-MB assay is a paramagnetic particle, chemiluminescent immunoassay for the quantitative determination of CK-MB levels in human serum and plasma using the Access Immunoassay Systems. · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 15099590232368), received between Oct 27, 2016 and Oct 27, 2016 — classified as 1 malfunction.
The most frequently reported specific device problem is “Incorrect, Inadequate or Imprecise Result or Readings” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Incorrect, Inadequate or Imprecise Result or Readings1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 27, 2016Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings
THE CUSTOMER REPORTED OBTAINING A NON-REPRODUCIBLE CREATINE KINASE, ISOENZYME MB (ACCESS CK-MB) RESULTS GENERATED FROM THE LABORATORY'S UNICEL DXI 800 ACCESS IMMUNOASSAY SYSTEM SERIAL NUMBER (B)(4) FOR A PATIENT SAMPLE. ON (B)(6) 2016, AN ELEVATED ACCESS CK-MB RESULT OF 46.848 NG/ML WAS GENERATED. THE SAME SAMPLE WAS REPEATED AND LOWER RESULTS OF 2.456 NG/ML AND 2.046 NG/ML WERE OBTAINED. THE RESULTS WERE NOT REPORTED OUTSIDE OF THE LABORATORY. THERE WERE NO REPORTS OF PATIENT INJURIES OR CHANGE TO PATIENT TREATMENT ASSOCIATED WITH THIS EVENT. MDR 2122870-2016-00507 WILL ADDRESS THE TROPONIN I (ACCESS ACCUTNI+3) RESULTS OBTAINED ON (B)(6) 2016 FOR THIS SAME PATIENT. SYSTEM PARAMETERS INCLUDING QUALITY CONTROLS (QCS) AND SYSTEM CHECKS WERE RECOVERING WITHIN ASSAY AND SYSTEM PARAMETERS. CALIBRATION DATA WAS NOT PROVIDED FOR REVIEW. THE SAMPLES WERE COLLECTED IN A 13X100 MM LITHIUM HEPARIN TUBE THAT WAS CENTRIFUGED AT 3000 REVOLUTIONS PER MINUTE (RPM) FOR 5 MINUTES AT ROOM TEMPERATURE. A BECKMAN COULTER (BEC) FIELD SERVICE ENGINEER (FSE) WAS DISPATCHED TO ASSESS THE ANALYZER'S PERFORMANCE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6060677 ↗
FDA clearance and classification
The FDA regulates product code JHX (fluorometric method, cpk or isoenzymes) under 21 CFR 862.1215 as a Class II device. 21 CFR 862.1215 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Access CK-MB 386371
Has the Access CK-MB 386371 been recalled?
No FDA recall record in our data names this exact device identifier (DI 15099590232368), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Access CK-MB 386371?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Oct 27, 2016. That report lists device problem “Incorrect, Inadequate or Imprecise Result or Readings” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Access CK-MB 386371?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the Access CK-MB 386371, and is it still sold?
The FDA's device database lists Beckman Coulter, Inc. as the company responsible for it (brand Access CK-MB, model 386371). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Fluorometric Method, Cpk Or Isoenzymes devices
- Stratus® CS 10444834Siemens Healthcare Diagnostics Inc. · FLUOROMETRIC METHOD, CPK OR ISOENZYMES71 reports
- VITROS 1896836Ortho Clinical Diagnostics · FLUOROMETRIC METHOD, CPK OR ISOENZYMES4 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page