Access hFSH 33520Recalls & reported problems
Beckman Coulter, Inc. · The Access hFSH assay is a paramagnetic particle, chemiluminescent immunoassay for the quantitative determination of follicle stimulating hormone (FSH) levels in human serum and plasma using the Access Immunoassay Systems. · Class 1
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 15099590575236), received between Apr 17, 2019 and Apr 17, 2019 — classified as 1 injury.
The most frequently reported specific device problem is “High Test Results” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- High Test Results1
Patient problems
- No Code Available1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryApr 17, 2019High Test Results; High Test Results
THE CUSTOMER CONTACTED BECKMAN COULTER (BCI) TO REPORT OBTAINING A HIGHER THAN EXPECTED FOLLICLE STIMULATING HORMONE (ACCESS HFSH) RESULT FOR ONE FEMALE PATIENT ON THE LABORATORY¿S ACCESS 2 IMMUNOASSAY ANALYZER SERIAL NUMBER (B)(4). THE FIRST ACCESS HFSH RESULT QUESTIONED WAS ON (B)(6) 2019. THE CUSTOMER TOOK THE PATIENT OFF OF THEIR BIRTH-CONTROL MEDICATION AT THIS TIME. ANOTHER SAMPLE WAS COLLECTED AND TESTED FOR ACCESS HFSH AGAIN; ANOTHER HIGHER THAN EXPECTED RESULT WAS OBTAINED. THE CUSTOMER PERFORMED LINEAR DILUTIONS AND NOTED THAT THE RESULTS OBTAINED WERE NOT LINEAR SUGGESTING THAT A PATIENT-SOURCE INTERFERENT WAS PRESENT. THE PATIENT THEN HAD AN MRI (MAGNETIC RESONANCE IMAGING) OF THE HEAD PERFORMED WHICH WAS NORMAL (IT IS UNKNOWN IF CONTRAST DYE WAS USED). IN ADDITION, THE PATIENT RECEIVED TREATMENT WITH A GNRH (GONADOTROPIN-RELEASING HORMONE) ANTAGONIST, HOWEVER, THE ACCESS HFSH RESULT WAS STILL HIGHER THAN EXPECTED. ON (B)(6) 2019 A THIRD SAMPLE WAS TESTED FOR THE ACCESS HFSH ASSAY AND THE RESULT WAS SIMILAR; STILL ELEVATED. THIS SAMPLE WAS ALSO SENT TO A REFERENCE LABORATORY WHICH USED A DIFFERENT METHODOLOGY (TYPE UNKNOWN) AND PRETREATMENT WITH A BLOCKING REAGENT. THE
Patient problems: No Code Available
MAUDE report 8524260 ↗
FDA clearance and classification
The FDA regulates product code CGJ (radioimmunoassay, follicle-stimulating hormone) under 21 CFR 862.1300 as a Class I device. 21 CFR 862.1300 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Access hFSH 33520
Has the Access hFSH 33520 been recalled?
No FDA recall record in our data names this exact device identifier (DI 15099590575236), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Access hFSH 33520?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Apr 17, 2019. That report lists device problem “High Test Results” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Access hFSH 33520?
None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Access hFSH 33520 FDA approved?
Devices of this type (product code CGJ) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Beckman Coulter, Inc.
Who makes the Access hFSH 33520, and is it still sold?
The FDA's device database lists Beckman Coulter, Inc. as the company responsible for it (brand Access hFSH, model 33520). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Radioimmunoassay, Follicle-Stimulating Hormone devices
- VIDAS® FSH 30407-01Biomerieux SA · RADIOIMMUNOASSAY, FOLLICLE-STIMULATING HORMONE1 recall0 reports
- VITROS 1931922Ortho Clinical Diagnostics · RADIOIMMUNOASSAY, FOLLICLE-STIMULATING HORMONE1 recall0 reports
- Elecsys FSH 08932352190Roche Diagnostics GmbH · RADIOIMMUNOASSAY, FOLLICLE-STIMULATING HORMONE4 reports
- Elecsys FSH 11775863122Roche Diagnostics GmbH · RADIOIMMUNOASSAY, FOLLICLE-STIMULATING HORMONE2 reports
- Elecsys FSH 08932387190Roche Diagnostics GmbH · RADIOIMMUNOASSAY, FOLLICLE-STIMULATING HORMONE1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page