M-Drain Centesis Catheter D40105007Recalls & reported problems
Mermaid Medical A/S · M-Drain Centesis Catheter is used in percutaneous fluid aspirations and small volume drainage procedures. · Class 1 · Implant
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 15711055001981), received between Jun 4, 2021 and Jul 9, 2021 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Defective Device” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Defective Device1
- Device Markings/Labelling Problem1
- Inadequacy of Device Shape and/or Size1
- Packaging Problem1
- Product Quality Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- Pleural Effusion1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 9, 2021Packaging Problem
PATIENT WITH HISTORY OF HYPERTENSION, CORONARY ARTERY DISEASE POST CORONARY ARTERY BYPASS GRAFT SURGERY X 5, AND RECENT LEFT PLEURAL EFFUSION WAS ADMITTED FOR AN ULTRASOUND GUIDED LEFT THORACENTESIS. DURING THE PREPARATION, IT WAS OBSERVED THAT THE NEEDLE FOR THIS CATHETER WAS LONGER THAN IT WAS SUPPOSED TO BE. THE PRODUCT MANUFACTURER IS MERMAID MEDICAL AND IT WAS A 5FX7CM M-DRAIN CENTESIS CATHETER. THIS DEVICE WAS NEVER USED IN THE PATIENT. PLEASE NOTE THAT THIS IS THE 4TH NEEDLE (3RD REPORT) THAT THE NEEDLE SIZE WAS INCORRECTLY PACKAGED.
Patient problems: Pleural Effusion
MAUDE report 12142279 ↗MalfunctionJul 7, 2021Device Markings/Labelling Problem
PATIENT WITH A HISTORY OF HYPERTENSION, RECENT SHORTNESS OF BREATH, AND RIGHT PLEURAL EFFUSION WAS ADMITTED FOR A RIGHT THORACENTESIS. WHEN THE MERMAID MEDICAL A/S M-DRAIN CENTESIS CATHETER WAS OPENED, IT WAS OBSERVED THAT THE CATHETER THAT WAS IDENTIFIED AS A 5F X 7CM CENTESIS CATHETER HAD A NEEDLE THAT WAS 12 CM LONG INSTEAD. THIS DEVICE WAS NOT USED ON THE PATIENT. PLEASE NOTE THIS IS THE 3RD REPORT FOR THE SAME PRODUCT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12127301 ↗MalfunctionJun 4, 2021Product Quality Problem; Inadequacy of Device Shape and/or Size; Defective Device
PATIENT WITH HISTORY OF DIABETES MELLITUS, HYPERTENSION, PROGRESSIVE DYSPNEA, AND PLEURAL EFFUSION WAS ADMITTED FOR AN ULTRASOUND-GUIDED THORACENTESIS. WHEN OPENING THE M-DRAIN 5F X 7 CM CENTESIS CATHETER, HEALTH CARE PROVIDER(S) NOTICED THERE WAS A 10 CM NEEDLE IN THE 7 CM SHEATH. ANOTHER DEVICE WAS OPENED WITH THE SAME ISSUE WHERE THE NEEDLE WAS TOO LONG. BOTH M-DRAIN CENTESIS CATHETER HAD THE SAME LOT NUMBER. THIS EQUIPMENT WAS NOT USED ON THE PATIENT AS THE TECHNOLOGIST AND PA NOTICED THE MALFUNCTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11938063 ↗
Other Needle, Catheter devices
- Cook G09490Cook Incorporated · NEEDLE, CATHETER1 recall9 reports
- Cook G10100Cook Incorporated · NEEDLE, CATHETER7 reports
- Cook G09492Cook Incorporated · NEEDLE, CATHETER7 reports
- MAK-NV™ 00884450013588Merit Medical Systems, Inc. · NEEDLE, CATHETER6 reports
- Cook G09489Cook Incorporated · NEEDLE, CATHETER5 reports
- MAK-NV™ 00884450088791Merit Medical Systems, Inc. · NEEDLE, CATHETER5 reports
- Ring G03388Cook Incorporated · NEEDLE, CATHETER5 reports
- Skater™ Introducer System 651506300Argon Medical Devices, Inc. · Needle, Catheter5 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.