Orthofix External Fixation Screw (Pin) with Hydroxyapatite coating 1 (REF 99-612670)Recalls & reported problems
Orthofix Srl · XCALIBER OSTEOTITE SCREW L 260/70 MM THREAD D 6.0-5.6MM · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 18032568862195), received between Aug 30, 2017 and Aug 30, 2017 — classified as 1 injury.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Fracture1
Patient problems
- Device Embedded In Tissue or Plaque1
- No Code Available1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryAug 30, 2017Fracture; Fracture
THE INFORMATION PROVIDED BY THE LOCAL DISTRIBUTOR INDICATES: - HOSPITAL NAME: (B)(6), - SURGEON'S NAME: DR. (B)(6), - DATE OF SURGERY: (B)(6) 2017, - BODY PART TO WHICH DEVICE WAS APPLIED: FEMUR, - SURGERY DESCRIPTION: FRACTURE TREATMENT, - PATIENT INFORMATION: (B)(6), MALE, - PROBLEM OBSERVED DURING: CLINICAL USE ON PATIENT/INTRAOPERATIVE, - TYPE OF PROBLEM: DEVICE FUNCTIONAL PROBLEM, - EVENT DESCRIPTION: "PATIENT HAS BEEN TREATED DUE TO POLYTRAUMATISM. A GALAXY KIT HAS BEEN USED. FIRST SCREW WAS FIXED WITHOUT ISSUE. WHEN INSERTING SECOND ONE, IT GOT BROKEN NEARBY SECOND CORTICAL. HEAD AND THREAD PART KEPT IN FIRST CORTICAL AND MEDULLARY CANAL. SCREW WAS INTRODUCED HANDLY WITH PRE-DRILLING AT 4.8 MM". THE COMPLAINT REPORT FORM ALSO INDICATES: - THE DEVICE FAILURE HAD ADVERSE EFFECTS ON PATIENT: MULTIPLE INCISIONS TO RETRIEVE SCREW FRAGMENTS AND PROLONGATION OF SURGERY TIME. UN-RETRIEVED DEVICE FRAGMENTS. - THE INITIAL SURGERY WAS COMPLETED WITH THE DEVICE. - THE EVENT LED TO A CLINICALLY RELEVANT INCREASE IN THE DURATION OF THE SURGICAL PROCEDURE: DRILLING IN ORDER TO SORT OUT SCREW FRAGMENT. - AN ADDITIONAL SURGERY WAS NOT REQUIRED. - A MEDICAL INTERVENTION WAS NOT REQUIRED. - CO
Patient problems: Device Embedded In Tissue or Plaque; No Code Available
MAUDE report 6829538 ↗
Other Pin, Fixation, Threaded devices
- ORTHOFIX MODULSYSTEM 1Orthofix Srl · Pin, Fixation, Threaded1 recall2 reports
- ORTHOFIX MODULSYSTEM 1Orthofix Srl · Pin, Fixation, Threaded1 recall0 reports
- ORTHOFIX MODULSYSTEM 1Orthofix Srl · Pin, Fixation, Threaded1 recall0 reports
- ORTHOFIX MODULSYSTEM 1Orthofix Srl · Pin, Fixation, Threaded1 recall0 reports
- APEX 5038-1-080Stryker GmbH · PIN, FIXATION, THREADED48 reports
- Agee Digit Widget® DWD-232Hand Biomechanics Lab Inc · Pin, Fixation, Threaded32 reports
- SPATIAL FRAME 71070720Smith & Nephew, Inc. · PIN, FIXATION, THREADED15 reports
- APEX 5038-2-110Stryker GmbH · PIN, FIXATION, THREADED11 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page