OSCAR 3 1 (REF OHP2080SU)Recalls & reported problems
Orthofix Srl · SINGLE USE 8MM PIERCER PROBE – STERILE · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 18056099649766), received between Apr 28, 2021 and Apr 28, 2021 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- Foreign Body In Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 28, 2021Break; Break
THE INFORMATION INITIALLY PROVIDED BY LOCAL DISTRIBUTOR INDICATES: - PRODUCT CODE: OHS2080SU AND OHP2080SU (MFR REPORTS 9680825-2021-00033 AND 9680825-2021-00034 RESPECTIVELY) - BATCH NUMBERS: B1455982 AND B1472893 - QUANTITY: 1 EACH - DATE OF INITIAL SURGERY: (B)(6) 2021 - BODY PART TO WHICH DEVICE WAS APPLIED: FEMUR - SURGERY DESCRIPTION: ARTHROPLASTY REVISION - PROBLEM OBSERVED DURING: CLINICAL USE ON PATIENT/INTRAOPERATIVE - TYPE OF PROBLEM: DEVICE FUNCTIONAL PROBLEM - EVENT DESCRIPTION: "WHEN BEING USED INTRAOPERATIVELY THE TIPS OF THE PROBES BROKE OFF THE PROBES. THE TIPS RESIDE IN THE PATIENT'S FEMUR. THE SURGEON WAS UNABLE TO REMOVE THE BROKEN TIPS". THE COMPLAINT REPORT FORM ALSO INDICATED: - THE DEVICE FAILURE HAD ADVERSE EFFECTS ON PATIENT (UN-RETRIEVED DEVICE FRAGMENTS) - THE EVENT LED TO A DELAY IN THE DURATION OF THE SURGICAL PROCEDURE - AN ADDITIONAL SURGERY WAS NOT REQUIRED - A MEDICAL INTERVENTION (OUTPATIENT CLINIC) WAS NOT REQUIRED - COPY OF OPERATIVE REPORTS ARE AVAILABLE (NOT RECEIVED BY ORTHOFIX (B)(4)) - PRODUCT IS NOT AVAILABLE FOR RETURN ON APRIL 14, 2021, ORTHOFIX (B)(4) RECEIVED THE FOLLOWING DETAILS FROM THE SALES REPRESENTATIVE: "THE HOSPITAL DISPOSED O
Patient problems: Foreign Body In Patient
MAUDE report 11736293 ↗
Other System, Cement Removal Extraction devices
- OSCAR 3 1Orthofix Srl · System, Cement Removal Extraction5 reports
- OSCAR 3 1Orthofix Srl · System, Cement Removal Extraction4 reports
- OSCAR 3 1Orthofix Srl · System, Cement Removal Extraction3 reports
- OSCAR 3 1Orthofix Srl · System, Cement Removal Extraction1 report
- OSCAR 3 1Orthofix Srl · System, Cement Removal Extraction1 report
- OSCAR 3 1Orthofix Srl · System, Cement Removal Extraction1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.