MesireTM Guide - Sinus Guide Catheter MSG070Recalls & reported problems
Meril Life Sciences Private Limited · MesireTM Guide - Sinus Guide Catheter, Angle 70° · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 18904224901510), received between Jan 2, 2019 and Jan 2, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Detachment of Device or Device Component1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 2, 2019Detachment of Device or Device Component; Detachment of Device or Device Component
THE PHYSICIAN WAS DOING AN OFFICE BALLOON DILATATION ON ALL SIX (6) SINUSES ON A PATIENT WITH LARGE MIDDLE TURBINATES. THE PHYSICIAN WAS ABLE TO SUCCESSFULLY DILATE BOTH THE SPHENOID SINUSES WITHOUT ANY ISSUES. THE PHYSICIAN STARTED TO DO LEFT FRONTAL SINUS WITH MINIMAL SPACE IN THE OSTEOMEATAL COMPLEX, IN ATTEMPT TO REPOSITION THE TIP OF THE GUIDE CATHETER HE USED THE WINGS TO TRY AND TORQUE THE TIP IN A NEW POSITION. THE WINGS A PART OF OUTER LUMEN SEPARATED FROM THE INNER LUMEN. THE PHYSICIAN RETRACTED THE SYSTEM. THERE WAS NO PATIENT INJURY REPORTED. THE PROCEDURE WAS COMPLETED USING A COMPETITOR CATHETER.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8207749 ↗
Other Instrument, Ent Manual Surgical devices
- n.a. 738756Karl Storz GmbH & Co. KG · INSTRUMENT, ENT MANUAL SURGICAL1 recall0 reports
- n.a. 738750Karl Storz GmbH & Co. KG · INSTRUMENT, ENT MANUAL SURGICAL1 recall0 reports
- n.a. 723014Karl Storz GmbH & Co. KG · INSTRUMENT, ENT MANUAL SURGICAL1 recall0 reports
- n.a. 738752Karl Storz GmbH & Co. KG · INSTRUMENT, ENT MANUAL SURGICAL1 recall0 reports
- n.a. 810506Karl Storz GmbH & Co. KG · INSTRUMENT, ENT MANUAL SURGICAL1 recall0 reports
- n.a. 810505Karl Storz GmbH & Co. KG · INSTRUMENT, ENT MANUAL SURGICAL1 recall0 reports
- n.a. 723400Karl Storz GmbH & Co. KG · INSTRUMENT, ENT MANUAL SURGICAL1 recall0 reports
- n.a. 738758Karl Storz GmbH & Co. KG · INSTRUMENT, ENT MANUAL SURGICAL1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page