CD HORIZON® Growth Rod Conversion Set 7340000GRRecalls & reported problems
Medtronic Sofamor Danek, Inc. · SET SCREW 7340000GR TI BREAK-OFF S · Class 2 · Implant
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 20643169549771), received between Jan 3, 2025 and Apr 22, 2025 — classified as 6 malfunctions.
The most frequently reported specific device problem is “Material Deformation” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Material Deformation4
- Break2
Patient problems
- No Clinical Signs, Symptoms or Conditions6
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 22, 2025Material Deformation; Material Deformation
INFORMATION WAS RECEIVED FROM A HEALTHCARE PROFESSIONAL VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT WITH PREOPERATIVE DIAGNOSIS FOR GROWING ROD EXTENSION TECHNIQUE. PROCEDURE OR THERAPY PERFORMED WAS EXTENSION SURGERY FOR THE GROWING ROD. IT WAS REPORTED THAT THE SET SCREW BROKE BEFORE THE BREAK-OFF. DURING GROWING ROD EXTENSION, THE DISTRACTOR CAME OFF AND INTERFERED WITH THE SET SCREW. IT IS BELIEVED THAT THE BREAKAGE WAS CAUSED BY THIS IMPACT. THERE WAS NO PATIENT SYMPTOMS OR COMPLICATIONS AS A RESULT OF THIS EVENT. THIS SURGERY IS A REPEAT SURGERY. DEVICE HAS BEEN EXPLANTED-PARTIALLY. PRODUCT WAS IMPLANTED AND EXPLANTED ON THE SAME DAY, (B)(6) 2023. THERE WERE NO FRAGMENTS LEFT INSIDE THE PATIENT BODY, SO NO PLAN FOR ADDITIONAL SURGERY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21879143 ↗MalfunctionApr 22, 2025Material Deformation; Material Deformation
INFORMATION WAS RECEIVED FROM A HEALTHCARE PROFESSIONAL VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT WITH PREOPERATIVE DIAGNOSIS FOR GROWING ROD EXTENSION TECHNIQUE. PROCEDURE OR THERAPY PERFORMED WAS EXTENSION SURGERY FOR THE GROWING ROD. IT WAS REPORTED THAT THE SET SCREW BROKE BEFORE THE BREAK-OFF. DURING GROWING ROD EXTENSION, THE DISTRACTOR CAME OFF AND INTERFERED WITH THE SET SCREW. IT IS BELIEVED THAT THE BREAKAGE WAS CAUSED BY THIS IMPACT. THERE WAS NO PATIENT SYMPTOMS OR COMPLICATIONS AS A RESULT OF THIS EVENT. THIS SURGERY IS A REPEAT SURGERY. DEVICE HAS BEEN EXPLANTED-PARTIALLY. PRODUCT WAS IMPLANTED AND EXPLANTED ON THE SAME DAY, (B)(6) 2023. THERE WERE NO FRAGMENTS LEFT INSIDE THE PATIENT BODY, SO NO PLAN FOR ADDITIONAL SURGERY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21879138 ↗MalfunctionApr 22, 2025Material Deformation; Material Deformation
INFORMATION WAS RECEIVED FROM A HEALTHCARE PROFESSIONAL VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT WITH PREOPERATIVE DIAGNOSIS FOR GROWING ROD EXTENSION TECHNIQUE. PROCEDURE OR THERAPY PERFORMED WAS EXTENSION SURGERY FOR THE GROWING ROD. IT WAS REPORTED THAT THE SET SCREW BROKE BEFORE THE BREAK-OFF. DURING GROWING ROD EXTENSION, THE DISTRACTOR CAME OFF AND INTERFERED WITH THE SET SCREW. IT IS BELIEVED THAT THE BREAKAGE WAS CAUSED BY THIS IMPACT. THERE WAS NO PATIENT SYMPTOMS OR COMPLICATIONS AS A RESULT OF THIS EVENT. THIS SURGERY IS A REPEAT SURGERY. DEVICE HAS BEEN EXPLANTED-PARTIALLY. PRODUCT WAS IMPLANTED AND EXPLANTED ON THE SAME DAY, (B)(6) 2023. THERE WERE NO FRAGMENTS LEFT INSIDE THE PATIENT BODY, SO NO PLAN FOR ADDITIONAL SURGERY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21879126 ↗MalfunctionMar 28, 2025Break; Break
INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING SPINAL THERAPY. IT WAS REPORTED THAT THEY REMOVED FRAGMENTS OF THE SET SCREW AFTER FINAL TIGHTENING. FRAGMENTS OF THE PRODUCT FELL TO THE PLEURA LEVEL, RAISING SUSPICIONS OF COMPLICATIONS INVOLVING THE LUNG. THERE WAS NO PATIENT SYMPTOM REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT. ADDITIONAL INFORMATION WAS RECEIVED FROM THE MANUFACTURER REPRESENTATIVE THAT THE TYPE OF PROCEDURE/THERAPY INVOLVED DURING THE EVENT WAS GLOW INGROD METHOD FOR CHILDHOOD SCOLIOSIS. REOPERATION DUE TO ONE-SIDED ROD BREAKAGE. ROD IMPLANTING DATE: (B)(6) 2024. THE DAMAGED ROD WAS REMOVED AND A NEW ROD WAS INSTALLED. THE ACTUAL PRODUCT HAS BEEN DISCARDED AND COULD NOT BE RETURNED. A THREADED PIECE OF THE SET SCREW FELL OUT INTO THE BODY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21718519 ↗MalfunctionJan 5, 2025Material Deformation; Material Deformation
INFORMATION WAS RECEIVED FROM A HEALTHCARE PROFESSIONAL VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT WITH PREOPERATIVE DIAG NOSIS FOR GROWING ROD EXTENSION TECHNIQUE. PROCEDURE OR THERAPY PERFORMED WAS EXTENSION SURGERY FOR THE GROWING ROD. IT WAS REPORTED THAT THE SET SCREW BROKE BEFORE THE BREAK-OFF. DURING GROWING ROD EXTENSION, THE DISTRACTOR CAME OFF AND INTERFERED WITH THE SET SC REW. IT IS BELIEVED THAT THE BREAKAGE WAS CAUSED BY THIS IMPACT. THERE WAS NO PATIENT SYMPTOMS OR COMPLICATIONS AS A RESULT OF THIS EVENT. THIS SURGERY IS A REPEAT SURGERY. DEVICE HAS BEEN EXPLANTED-PARTIALLY. PRODUCT WAS IMPLANTED AND EXPLANTED ON THE SAME DAY, (B)(6) 2023. THERE WERE NO FRAGMENTS LEFT INSIDE THE PATIENT BODY, SO NO PLAN FOR ADDITIONAL SURGERY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21076053 ↗MalfunctionJan 3, 2025Break; Break
INFORMATION WAS RECEIVED FROM A HEALTHCARE PROFESSIONAL VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT WITH PREOPERATIVE DIAGNOSIS FOR GROWING ROD EXTENSION TECHNIQUE. PROCEDURE OR THERAPY PERFORMED WAS EXTENSION SURGERY FOR THE GROWING ROD. IT WAS REPORTED THAT THE SET SCREW BROKE BEFORE THE BREAK-OFF. DURING GROWING ROD EXTENSION, THE DISTRACTOR CAME OFF AND INTERFERED WITH THE SET SCREW. IT IS BELIEVED THAT THE BREAKAGE WAS CAUSED BY THIS IMPACT. THERE WAS NO PATIENT SYMPTOMS OR COMPLICATIONS AS A RESULT OF THIS EVENT. THIS SURGERY IS A REPEAT SURGERY. DEVICE HAS BEEN EXPLANTED-PARTIALLY. PRODUCT WAS IMPLANTED AND EXPLANTED ON THE SAME DAY, (B)(6) 2023. THERE WERE NO FRAGMENTS LEFT INSIDE THE PATIENT BODY, SO NO PLAN FOR ADDITIONAL SURGERY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21067994 ↗
FDA clearance and classification
Cleared through Special 510(k) K150200 on Feb 25, 2015 (decision: Substantially Equivalent). Submitted by Medtronic Sofamor Danek USA, Incorporated as “CD HORIZON Growth Rod Conversion Set”. The FDA review took 27 days. FDA record ↗
The FDA regulates product code PGM (growing rod system) under 21 CFR 888.3070 as a Class II device. 21 CFR 888.3070 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the CD HORIZON® Growth Rod Conversion Set 7340000GR
Has the CD HORIZON® Growth Rod Conversion Set 7340000GR been recalled?
No FDA recall record in our data names this exact device identifier (DI 20643169549771), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the CD HORIZON® Growth Rod Conversion Set 7340000GR?
The FDA's MAUDE database lists 6 adverse event reports for this device, received between Jan 3, 2025 and Apr 22, 2025. In those reports, the most common specific device problems are “Material Deformation” (4) and “Break” (2). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the CD HORIZON® Growth Rod Conversion Set 7340000GR?
None of the reports are classified as deaths, 0 as injuries and 6 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the CD HORIZON® Growth Rod Conversion Set 7340000GR FDA approved?
It was cleared through Special 510(k) K150200 on Feb 25, 2015. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the CD HORIZON® Growth Rod Conversion Set 7340000GR MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.
Who makes the CD HORIZON® Growth Rod Conversion Set 7340000GR, and is it still sold?
The FDA's device database lists Medtronic Sofamor Danek, Inc. as the company responsible for it (brand CD HORIZON® Growth Rod Conversion Set, model 7340000GR). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Growing rod system devices
- SHILLA™ Growth Guidance System 7675500Medtronic Sofamor Danek, Inc. · Growing rod system1 report
- VerteGlide Spinal Growth Guidance System 00-1724-5035Orthopediatrics Corp. · Growing rod system1 report
- EXPEDIUM 186172680Depuy Spine, LLC · Growing rod system1 report
- VerteGlide Spinal Growth Guidance System 00-1722-4530Orthopediatrics Corp. · Growing rod system1 report
- EXPEDIUM 186172640Depuy Spine, LLC · Growing rod system1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page