Halyard 29980Recalls & reported problems
O&M Halyard, Inc. · HALYARD* I.V. Therapy HAND-AID* Arterial Wrist Support, Adult · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 20680651299806), received between Apr 16, 2021 and Apr 7, 2023 — classified as 4 injuries.
The most frequently reported specific device problem is “Fitting Problem” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Fitting Problem2
- Pressure Problem2
Patient problems
- Device Embedded In Tissue or Plaque4
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryApr 7, 2023Pressure Problem; Pressure Problem
PATIENT # TWO. IT WAS INITIALLY REPORTED BY COMPLAINANT THAT THERE WAS A PRESSURE INJURY THAT OCCURRED IN THE ICU IN (B)(6) AS A RESULT OF ARTERIAL STABILIZATION DEVICE. COMPLAINANT PROVIDED ADDITIONAL INFORMATION STATING THERE WERE TWO INCIDENTS. EVENT DATES WERE: (B)(6) 2023 AND THE NUMBER OF PATIENTS WERE TWO. PATIENT 2: THE PATIENT HAS BEEN DISCHARGED. THE DEVICE WAS REMOVED AND/OR WAS REPLACED WITH DIFFERENT FOAM ARTERIAL DEVICE. THE LOCATION OF THE INJURY WAS THE LEFT HAND INNER PALM. THE TYPE OF INJURY WAS A DEEP TISSUE PRESSURE WOUND. THE PROCEDURE AN ARTERIAL LINE STABILIZATION APPLIED IN THE EMERGENCY ROOM (ER). THE PATIENT WAS SENT TO THE INTENSIVE CARE UNIT WITH THE DEVICE IN PLACE FROM ER.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 16700950 ↗InjuryApr 6, 2023Pressure Problem; Pressure Problem
PATIENT # ONE. IT WAS INITIALLY REPORTED BY COMPLAINANT THAT THERE WAS A PRESSURE INJURY THAT OCCURRED IN THE ICU IN JANUARY AS A RESULT OF ARTERIAL STABILIZATION DEVICE. COMPLAINANT PROVIDED ADDITIONAL INFORMATION STATING THERE WERE TWO INCIDENTS. EVENT DATES WERE: (B)(6) 2023 AND (B)(6) 2023 AND THE NUMBER OF PATIENTS WERE TWO. PATIENT 1: THE PATIENT HAS BEEN DISCHARGED. THE DEVICE WAS REMOVED AND/OR WAS REPLACED WITH DIFFERENT FOAM ARTERIAL DEVICE. THE LOCATION OF THE INJURY WAS THE LEFT HAND INNER PALM. THE TYPE OF INJURY WAS A DEEP TISSUE PRESSURE WOUND. THE PROCEDURE AN ARTERIAL LINE STABILIZATION APPLIED IN THE EMERGENCY ROOM (ER). THE PATIENT WAS SENT TO THE INTENSIVE CARE UNIT WITH THE DEVICE IN PLACE FROM ER.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 16694604 ↗InjuryApr 16, 2021Fitting Problem; Fitting Problem
O&M HALYARD, INC. RECEIVED A SINGLE REPORT THAT REFERENCED TWO DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING TWO DIFFERENT PATIENTS. THIS IS THE SECOND OF TWO REPORTS. REFER TO 3014421917-2021-00001 FOR THE FIRST PATIENT. IT WAS REPORTED BY THE CUSTOMER WHO STATED, WE ARE REACHING OUT TO YOU TO INFORM YOU OF AN ISSUE WE ARE HAVING USING YOUR ARTERIAL WRIST SUPPORT. WE HAVE HAD ISSUES WITH THEM CAUSING PRESSURE SORES BETWEEN THE THUMB AND FORE FINGER. ADDITIONAL INFORMATION WAS RECEIVED ON 9-APRIL-2021 THAT STATES, THERE WARE TWO PATIENTS WHO HAVE UNSTAGEABLE PRESSURE INJURIES. NO ADDITIONAL INFORMATION HAS BEEN RECEIVED.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 11680326 ↗InjuryApr 16, 2021Fitting Problem; Fitting Problem
O&M HALYARD, INC. RECEIVED A SINGLE REPORT THAT REFERENCED TWO DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING TWO DIFFERENT PATIENTS. THIS IS THE FIRST OF TWO REPORTS. REFER TO 3014421917-2021-00002 FOR THE SECOND PATIENT. IT WAS REPORTED BY THE CUSTOMER WHO STATED, WE ARE REACHING OUT TO YOU TO INFORM YOU OF AN ISSUE WE ARE HAVING USING YOUR ARTERIAL WRIST SUPPORT. WE HAVE HAD ISSUES WITH THEM CAUSING PRESSURE SORES BETWEEN THE THUMB AND FORE FINGER. ADDITIONAL INFORMATION WAS RECEIVED ON 9-APRIL-2021 THAT STATES, THERE WARE TWO PATIENTS WHO HAVE UNSTAGEABLE PRESSURE INJURIES. NO ADDITIONAL INFORMATION HAS BEEN RECEIVED.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 11679603 ↗
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page