RELIEVA TRACT RT1640AZRecalls & reported problems
Acclarent, Inc. · RELIEVA TRACT BALLOON DILATION SYSTEM, 16X40MM - 1PK · Class 1
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 20705031462653), received between Sep 1, 2021 and Sep 1, 2021 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Hyporesponsive to stimuli1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjurySep 1, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE HEALTHCARE PROFESSIONAL REPORTED THAT THE (B)(6) FEMALE PATIENT WITH A HISTORY OF HYPOTHYROIDISM UNDERWENT PRIMARY PROCEDURES IN THE FOLLOWING ORDER: BILATERAL PARTIAL INFERIOR TURBINATE REDUCTION, BALLOON SEPTOPLASTY, IMAGE GUIDANCE, BILATERAL FRONTAL BALLOON SINUPLASTY, BILATERAL SPHENOID BALLOON SINUPLASTY, BILATERAL MAXILLARY BALLOON SINUPLASTY ENDING WITH BILATERAL FRONTAL PROPEL CONTOUR PLACEMENT AND POSISEP X PLACEMENT ADJACENT TO THE TURBINATE INCISIONS ON (B)(6) 2021, USING THE 16 X 40 MM RELIEVA TRACT BALLOON DILATION SYSTEM (RT1640AZ / UNKNOWN LOT#) SUFFERED FROM INSTANT, PERSISTING NUMBNESS AND SENSORY LOSS IN THE HARD / SOFT PALATE. THE PATIENT WAS PLACED ON ORAL STEROID PREDNISONE AND IT WAS DISCUSSED WITH THE PHYSICIAN OF A POSSIBLE NEUROLOGICAL CONSULTATION VERSUS POSSIBLY STARTING THE PATIENT ON GABAPENTIN TO HELP REDUCE THE SENSORY NERVE IRRITATION. THE PATIENT IS CURRENTLY IN STABLE CONDITION WITH PERSISTENT PALATE NUMBNESS. DURING THE PROCEDURE, IT WAS REPORTED THAT WHILE THE RELIEVA TRACT BALLOON WAS BEING INFLATED IN THE PATIENT¿S RIGHT-SIDE SEPTUM, THE PATIENT ¿JUMPED¿ AND STATED THAT SHE FELT PAIN THEN NUMBNESS IN THE HARD / SOFT PALATE. THE BALLOON CATH
Patient problems: Hyporesponsive to stimuli
MAUDE report 12410529 ↗
FDA clearance and classification
Cleared through 510(k) K183090 on Apr 19, 2019 (decision: Substantially Equivalent). Submitted by Acclarent, Inc. as “Relieva Tract Balloon Dilation System”. The FDA review took 164 days. FDA record ↗
The FDA regulates product code QGK (balloon, nasal airway) under 21 CFR 874.4420 as a Class I device. 21 CFR 874.4420 ↗
FDA definition of this device type: The nasal airway balloon is intended to provide increased intranasal space to facilitate access for endonasal and transnasal procedures and/or temporarily address nasal obstruction.
Common questions about the RELIEVA TRACT RT1640AZ
Has the RELIEVA TRACT RT1640AZ been recalled?
No FDA recall record in our data names this exact device identifier (DI 20705031462653), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the RELIEVA TRACT RT1640AZ?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Sep 1, 2021. That report lists patient problem “Hyporesponsive to stimuli” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the RELIEVA TRACT RT1640AZ?
None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the RELIEVA TRACT RT1640AZ FDA approved?
It was cleared through 510(k) K183090 on Apr 19, 2019. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the RELIEVA TRACT RT1640AZ, and is it still sold?
The FDA's device database lists Acclarent, Inc. as the company responsible for it (brand RELIEVA TRACT, model RT1640AZ). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Balloon, nasal airway devices
- RELIEVA TRACT RT1640AAcclarent, Inc. · Balloon, nasal airway7 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page