VISTA BRITE TIP 67008400Recalls & reported problems
Cordis Corporation · 6F .070 JR 5 100CM · Class 2
All models of VISTA BRITE TIP (26)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 20705032020494), received between Nov 28, 2016 and Nov 28, 2016 — classified as 1 injury.
The most frequently reported specific device problem is “Detachment Of Device Component” (1 report).
1 other recall cover devices cleared under the same FDA submission (K963962); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Detachment Of Device Component1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryNov 28, 2016Detachment Of Device Component; Detachment Of Device Component
IT WAS REPORTED THAT THE LAST 10CM OF THE VISTA BRITE GUIDING CATHETER BROKE COMPLETELY OFF AND IS FLOATING IN THE AORTA. THE PHYSICIAN MANAGED TO SUCCESSFULLY RETRIEVE THE DISTAL TIP WITH A COOK SNARE. ANOTHER GUIDE CATHETER WAS USED AND STENTED OF THE RIGHT CORONARY WAS COMPLETED SUCCESSFULLY. THERE WERE NO PATIENT INJURIES. THE PHYSICIAN ADVANCED THE GUIDING CATHETER IN THE AORTA. WHEN HE ADVANCED IT OVER THE AORTA ARCH (BEFORE POSITIONING AND SELECTING A CORONARY) HE TURNED (TORQUED) THE CATHETER AND FELT THAT THE CATHETER DID NOT WANT TO MOVE. WHEN HE OBSERVED THE SCREEN HE SAW THAT THE LAST 10 CM OF THE CATHETER BROKE COMPLETELY OFF. ALL PARTS WERE KEPT, THE SHAFT AND THE BROKEN OFF TIP, PLACED IN A CIDEX FOR 10 MIN AND THEN FLUSHED WITH WATER AND CIDEX. THE DEVICE IS AVAILABLE FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6128557 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K963962. One submission often covers many models, so check the product and lot details in each record.
- Z-1198-2019 · Feb 7, 2019 · TerminatedCordis Vista Brite Tip & Androit Guiding Catheters Product Usage: The guiding catheter is intended for use for intravascular introduction of interventional/diagnostic devices into
Other CATHETER, PERCUTANEOUS devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page