Cordis PRECISE PRO Rx Nitinol Stent System PC0730RXCRecalls & reported problems
Cordis US Corp. · Class 3 · Implant
All models of Cordis PRECISE PRO Rx Nitinol Stent System (10)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 20705032036457), received between Mar 30, 2017 and Nov 24, 2020 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Crack” (1 report).
4 other recalls cover devices cleared under the same FDA submission (P030047); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Crack1
- Detachment of Device or Device Component1
Patient problems
- No Consequences Or Impact To Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 24, 2020Detachment of Device or Device Component; Detachment of Device or Device Component
AS REPORTED, THE 7MM X 30MM PRECISE PRO RAPID EXCHANGE (RX) CAROTID STENT SYSTEM COULDN'T BE DELIVERED TO THE TARGET SITE THEN THE DOCTOR FOUND THE TIP WAS RIPPED AND FRAGMENTED. THERE WAS NO REPORTED PATIENT INJURY. THE DEVICE WAS OPENED IN STERILE FIELD. THE DEVICE WAS CONTAMINATED BUT WILL BE RETURNED FOR EVALUATION.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10896624 ↗MalfunctionMar 30, 2017Crack; Crack
DURING DEPLOYMENT OF THE PRECISE PRO RX US CAROTID SYSTEM STENT, THERE WAS SIGNIFICANT RESISTANCE AND THE STENT DELIVERY SYSTEM BROKE (THE DELIVERY SYSTEM CRACKED) WHILE ATTEMPTING TO APPROPRIATELY DELIVER THE STENT TO THE PROPER LOCATION. A DIFFERENT PRECISE PRO SYSTEM WAS USED TO COMPLETE THE PROCEDURE. DURING DEPLOYMENT THE PHYSICIAN FELT RESISTANCE AND THEN FELT NONE. THE STENT WAS NOT DEPLOYED BUT THE PART PINNED WAS AT THE ROTATING HEMOSTATIC VALVE (RHV). OUT AN ABUNDANCE OF CAUTION, THE PHYSICIAN REMOVED THE DEVICE AND DISCOVER THAT THE DELIVERY SYSTEM HAD BROKEN (CRACKED). THE PHYSICIAN TOOK A DIFFERENT PRECISE PRO CAROTID STENT AND COMPLETED THE CASE WITHOUT INCIDENT. THE PRODUCT WAS STORED, HANDLED, INSPECTED AND PREPPED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU). THE DEVICE WAS PREPPED APPROPRIATELY. THE PHYSICIAN IS FAMILIAR WITH THE DEVICE AND PERFORMED ALL PREP TASK APPROPRIATELY. THERE WASN'T ANYTHING UNUSUAL NOTED ABOUT THE STENT DELIVERY SYSTEM PRIOR TO USE. THE INTENDED PROCEDURE/TARGET LESION WAS THE CAROTID ARTERY, HOWEVER THE LESION CHARACTERISTICS ARE UNKNOWN. WHEN REMOVED FROM THE TRAY, THE STENT WAS STILL CONSTRAINED WITHIN THE OUTER MEMBER/SHEATH. THE FOLL
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6446843 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P030047. One submission often covers many models, so check the product and lot details in each record.
- Z-1257-2021 · Feb 11, 2021 · CompletedPRECISE PRO RX CAROTID STENT implant system, Product Codes: PC0520RXC, PC0530RXC, PC0540RXC, PC0620RXC, PC0630RXC, PC0640RXC, PC0720RXC, PC0730RXC, PC0740RXC, PC0820RXC, PC0830RXC
- Z-0729-2020 · Nov 14, 2019 · Open, ClassifiedCordis Precise Nitinol Stent System. The Cordis PRECISE Nitinol Stent System devices are designed to deliver a flexible, self-expanding endoluminal stent to the carotid vascula
- Z-1947-2016 · May 4, 2016 · TerminatedCordis PRECISE (R) RX Nitinol Stent System (Biliary)
- Z-1946-2016 · May 4, 2016 · TerminatedCordis PRECISE (R) PRO RX Nitinol Stent System (Carotid)
Other STENT, CAROTID devices
- Neuroguard IEP® System NG-0740-140-2Contego Medical, Inc. · Stent, Carotid2 recalls32 reports
- Neuroguard IEP® System NG-NV-6-40Contego Medical, Inc. · Stent, Carotid2 recalls9 reports
- Neuroguard IEP® System NG-NV-7-40Contego Medical, Inc. · Stent, Carotid2 recalls8 reports
- ENROUTE Transcarotid Stent SR-0940-CSSilk Road Medical, Inc. · Stent, Carotid1 recall5 deaths58 reports
- Neuroguard IEP® System NG-0640-140-2Contego Medical, Inc. · Stent, Carotid2 recalls7 reports
- ENROUTE Transcarotid Stent SR-1040-CSSilk Road Medical, Inc. · Stent, Carotid1 recall3 deaths56 reports
- CGuard Prime Carotid Stent System CND0840Inspire M.D Ltd · Stent, Carotid1 recall1 death41 reports
- CGuard Prime Carotid Stent System CND0940Inspire M.D Ltd · Stent, Carotid1 recall31 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page