S.M.A.R.T. RADIANZ SR08100XLRecalls & reported problems
Cordis US Corp. · S.M.A.R.T. RADIANZ Vascular Stent System 8x100mm 190CM · Class 3 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 20705032082393), received between Aug 3, 2023 and Apr 29, 2024 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Defective Component” (1 report).
4 other recalls cover devices cleared under the same FDA submission (P020036, P120002); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Defective Component1
- Detachment of Device or Device Component1
- Difficult or Delayed Positioning1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 29, 2024Detachment of Device or Device Component; Detachment of Device or Device Component
AS REPORTED, AFTER IMPLANTATION OF AN 8MM X 100MM SMART RADIANZ SELF-EXPANDING STENT (SES), WHEN REMOVING THE DELIVERY SYSTEM FROM THE PATIENT OVER A 300CM VASSALLO FLOPPY GUIDEWIRE, IT WAS NOTICED THAT THE FRONT END WAS TORN OFF. THE 10CM SEPARATED SEGMENT REMAINED ON THE VASSALLO GUIDEWIRE AND WAS ABLE TO BE REMOVED WITHOUT ISSUE BY PULLING THE GUIDEWIRE. ADDITIONALLY, THERE WAS SOME RESISTANCE WHEN REMOVING THE DELIVERY SYSTEM DUE TO RESISTANCE WITH THE GUIDEWIRE. THE PROCEDURE CONTINUED BY IMPLANTING A 7MM X 60MM SMART VASCULAR SES AT THE EXTERNAL ILIAC ARTERY (EIA). THE RIGHT COMMON ILIAC ARTERY WAS THEN TREATED, AND THE PROCEDURE WAS COMPLETED. THERE WERE NO REPORTED INJURIES TO THE PATIENT. THIS WAS DURING A PROCEDURE TO TREAT TWO SEPARATE LESIONS, ONE IN THE LEFT COMMON ILIAC ARTERY TO EXTERNAL ILIAC ARTERY (EIA), AND ONE IN THE RIGHT COMMON ILIAC ARTERY TO SUPERFICIAL FEMORAL ARTERY (SFA). THE EIA LESION HAD A STENOSIS OF 85% - 95% AND WAS MODERATELY CALCIFIED. THE SFA LESION HAD A STENOSIS OF 90%-100% AND WAS MODERATELY CALCIFIED. A 6F 90CM NON-CORDIS GUIDING SHEATH WAS USED FOR ACCESS FROM THE LEFT BRACHIAL ARTERY TO THE LEFT ILIAC ARTERY. VARIOUS UNKNOWN GUIDEWIRES WERE
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19201032 ↗MalfunctionDec 7, 2023Difficult or Delayed Positioning; Difficult or Delayed Positioning
AS REPORTED, WHEN USING AN 8MM X 100MM SMART RADIANZ SELF-EXPANDING STENT (SES) DELIVERY SYSTEM, THE STENT EDGE COULD BE DEPLOYED BUT THE STENT COULD NOT BE DEPLOYED. THE DEVICE WAS REPLACED WITH A NEW, UNKNOWN SMART CONTROL SES TO COMPLETE THE PROCEDURE. THERE WERE NO REPORTED INJURIES TO THE PATIENT. THIS WAS DURING A PROCEDURE TO TREAT AN ILIAC LESION. ADDITIONAL INFORMATION WAS REQUESTED BUT WAS NOT PROVIDED. THE DEVICE WILL NOT BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18286177 ↗MalfunctionAug 3, 2023Defective Component; Defective Component
AS REPORTED A SABERX RADIANZ PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) DILATION CATHETER WAS USED BUT RUPTURED DUE TO SEVERE CALCIFICATION. ADDITIONALLY, A 6F SMART RADIANZ VASCULAR STENT WAS USED BUT THE STENT LENGTH WAS LONGER THAN EXPECTED. THE COMPLAINT DEVICES WERE REPLACED WITH TWO DIFFERENT SABERX RADIANZ AND SMART RADIANZ DEVICES OF DIFFERENT SIZES AND THE PROCEDURE WAS COMPLETED. THERE WAS NO REPORTED PATIENT INJURY. THE DEVICES WERE BEING USED IN AN ENDOVASCULAR THERAPY (EVT) PROCEDURE. THE LENGTH OF THE LESION WAS ABOUT 8CM. THERE WAS SEVERE VESSEL TORTUOSITY WITH ONE-HUNDRED PERCENT (100%) STENOSIS. THERE WERE NO ISSUES EXPERIENCED WITH THE GUIDING SHEATH. THERE WERE NO VISIBLE SIGNS OF DEVICE/PACKAGE DAMAGE PRIOR TO USE. THERE WAS NO DIFFICULTY REMOVING THE PRODUCT FROM THE HOOP OR REMOVING THE PROTECTIVE BALLOON COVER NOR REMOVING THE STYLET OR ANY OF THE STERILE PACKAGING COMPONENTS. THERE WERE NO KINKS OR OTHER DAMAGES NOTED PRIOR TO INSERTING THE PRODUCT INTO THE PATIENT. THE DEVICE MAINTAINED NEGATIVE PRESSURE DURING PREPARATION. THERE WAS NO RESISTANCE/FRICTION WHILE INSERTING THE BALLOON INTO THE PATIENT. THERE WAS NO DIFFICULTY ADVANCING THE BALLOON CATHETER
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17451859 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P020036, P120002. One submission often covers many models, so check the product and lot details in each record.
- Z-1510-2025 · Mar 4, 2025 · Open, ClassifiedCordis, REF C10040ML, Smart Control Vascular Stent System ILIAC, 10mm X 40mm 6F, SterileEO, Rx Only
- Z-0728-2020 · Nov 14, 2019 · Open, ClassifiedS.M.A.R.T. Nitinol Stent System and the S.M.A.R.T. Control Nitinol Stent System. The SMART stent system includes a self-expanding stent made of Nitinol (nickel-titanium alloy)
- Z-1040-2012 · Jan 31, 2012 · TerminatedS.M.A.R.T. CONTROL NITINOL STENT SYSTEM ILIAC: Self-Expanding Vascular Stents delivered by catheter for the indication of improving luminal diameter in patients with symptomatic a
- Z-1556-2008 · Mar 10, 2008 · TerminatedCORDIS S.M.A.R.T. Control" Nitinol Stent System Model Number(s): C10040SL, Manufactured in Mexico. Indicated for improving luminal diameter in patients with symptomatic atheroscler
Other STENT, SUPERFICIAL FEMORAL ARTERY devices
- EverFlex™ EVD35-06-150-120Covidien LP · STENT, SUPERFICIAL FEMORAL ARTERY1 death110 reports
- SUPERA S-60-150-120-P6Abbott Vascular Inc. · STENT, SUPERFICIAL FEMORAL ARTERY108 reports
- SUPERA S-55-150-120-P6Abbott Vascular Inc. · STENT, SUPERFICIAL FEMORAL ARTERY88 reports
- LifeStent® Solo Vascular Stent EX062003CLBard Peripheral Vascular, Inc. · STENT, SUPERFICIAL FEMORAL ARTERY80 reports
- BioMimics 3D Vascular Stent System 144700-12Veryan Medical Limited · Stent, Superficial Femoral Artery74 reports
- SUPERA S-50-120-120-P6Abbott Vascular Inc. · STENT, SUPERFICIAL FEMORAL ARTERY55 reports
- EverFlex™ EVD35-07-060-120Covidien LP · STENT, SUPERFICIAL FEMORAL ARTERY1 recall5 reports
- EverFlex™ EVD35-07-120-120Covidien LP · STENT, SUPERFICIAL FEMORAL ARTERY1 recall5 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page