Medtronic Xomed, Inc. · ELECTRODE 8227414 5PK PRASS PRD 2CH ROHS · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 20763000038193), received between Mar 6, 2025 and Mar 6, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “False Negative Result” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • False Negative Result1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 6, 2025False Negative Result; False Negative Result

    IT WAS REPORTED WHILE SETTING UP THE NIM FOR THAT CASE IT PASSED ALL THE CHECKS, HOWEVER INTRA-OPERATIVELY THE BLUE CABLE STOPPED TRANSMITTING. TRIED TAPPING THE FACE AND USING THE NIM PROBE BUT GOT NO RESPONSE FROM THAT CABLE/ELECTRODE. ALSO TRIED USING A DIFFERENT BLOCK TO PLUG ALL THE ELECTRODES INTO, CHECKED THE ELECTRODE WAS IN THE CORRECT LOCATION AND SECURE, STARTED THE SET-UP PROCESS OVER, AND REBOOTED THE NIM MACHINE AND IT STILL WASN¿T WORKING. SO OPENED A SECOND PACKET OF ELECTRODES AND THAT BLUE CABLE WORKED PERFECTLY. REPLACED WITH A NEW LEAD AND THE PROCEDURE WAS COMPLETED. THERE WAS EXTENSION FOR 10 MINUTES IN PROCEDURE. NO KNOWN PATIENT IMPACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21536534 ↗