Synergetics 55.70.25PRecalls & reported problems
Synergetics USA, Inc. · 25ga Flexible Tapered Illuminated Laser Probe · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 20841305107094), received between Jun 15, 2022 and Jan 2, 2024 — classified as 3 injuries.
The most frequently reported specific device problem is “Fitting Problem” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Fitting Problem2
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- Eye Burn1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryJan 2, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A USER FACILITY REPORTED THAT DURING PROCEDURE THE SURGEON EXPERIENCED A VARIABLE UPTAKE ON THE LASER ON THE RETINA. SETTINGS WERE POWER 300, DURATION 100, INTERVAL 100. THE DURATION WAS RAISED TO 200, HOWEVER THE UPTAKE WAS STILL VARIABLE. AS A RESULT THE DOCTOR EXPERIENCED A HOT BURN THAT CAUSED A BREAK ON THE RETINA. A LASER RETINOPEXY WAS PERFORMED TO TREAT THE BREAK. THE CASE WAS COMPLETED WITHOUT FURTHER COMPLICATION.
Patient problems: Eye Burn
MAUDE report 18425924 ↗InjuryNov 16, 2023Fitting Problem; Fitting Problem
THE SALES REP ON SITE FOR SURGERY REPORTED THE LASER PROBE GOT STUCK IN THE TROCAR CANNULA DURING LASER RETINOPEXY. THE LASER PROBE WAS TOO THICK TO GO THROUGH CANNULA. THE DOCTOR ENDED UP HAVING TO SUTURE THE SCLEROTOMY WITH A VICRYL 7.0 SUTURE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18152268 ↗InjuryJun 15, 2022Fitting Problem; Fitting Problem
THE SALES REP ON SITE FOR SURGERY REPORTED THE LASER PROBE PULLED THE TROCAR OUT OF THE PATIENTS EYE. THE SURGERY WAS DELAYED MAYBE 10 MINUTES AND A SUTURE WAS REQUIRED TO CLOSE THE WOUND. NO ADDITIONAL ANESTHESIA REQUIRED. THEY WERE ABLE TO COMPLETE THE SURGERY WITH NO ADDITIONAL PRODUCTS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14699533 ↗
FDA clearance and classification
The FDA regulates product code HQB (photocoagulator and accessories) under 21 CFR 886.4690 as a Class II device. 21 CFR 886.4690 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Synergetics 55.70.25P
Has the Synergetics 55.70.25P been recalled?
No FDA recall record in our data names this exact device identifier (DI 20841305107094), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Synergetics 55.70.25P?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between Jun 15, 2022 and Jan 2, 2024. In those reports, the most common specific device problem is “Fitting Problem” (2); the most common patient problem is “Eye Burn” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Synergetics 55.70.25P?
None of the reports are classified as deaths, 3 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the Synergetics 55.70.25P, and is it still sold?
The FDA's device database lists Synergetics USA, Inc. as the company responsible for it (brand Synergetics, model 55.70.25P). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other PHOTOCOAGULATOR AND ACCESSORIES devices
- Alcon, Engauge 8065751114Alcon Laboratories, Inc. · Photocoagulator and accessories74 reports
- Vortex Surgical Inc. VS0135.25Vortex Surgical, Inc. · Photocoagulator And Accessories1 recall1 report
- Vortex Surgical Inc VS0110.25Vortex Surgical, Inc. · Photocoagulator And Accessories1 recall0 reports
- Vortex Surgical Inc VS0120.25Vortex Surgical, Inc. · Photocoagulator And Accessories1 recall0 reports
- Vortex Surgical Inc VS0140.25Vortex Surgical, Inc. · Photocoagulator And Accessories1 recall0 reports
- Vortex Surgical Inc VS0120.23Vortex Surgical, Inc. · Photocoagulator And Accessories1 recall0 reports
- Vortex Surgical Inc VS0130.25Vortex Surgical, Inc. · Photocoagulator And Accessories1 recall0 reports
- Vortex Surgical Inc VS0125.25BVortex Surgical, Inc. · Photocoagulator And Accessories1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page