ILIZAROV 102107Recalls & reported problems
Smith & Nephew, Inc. · WIRE WITH STOPPER 1.8MM DIAMETER 400MM · Class 2 · Implant
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 23596010031253), received between Dec 28, 2018 and Nov 29, 2023 — classified as 3 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Break” (3 reports).
19 other recalls cover devices cleared under the same FDA submission (K994143); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Break3
- Fracture2
Patient problems
- Failure of Implant2
- No Consequences Or Impact To Patient2
- Injury1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
InjuryNov 29, 2023Fracture; Fracture
IT WAS REPORTED THAT, DURING ILIZAROV EXTERNAL FIXATION TREATMENT, THE PATIENT EXPERIENCED BREAKAGE OF THE WIRE WITH STOPPER 400 MM. THE TSF CONFIGURATION IS TWO RINGS, THREE PINS PROXIMALLY, NO ADVERSE OBSERVATIONS. WIRE FIXATION BOLT USED ARE CONVENTIONAL ILIZAROV SLOTTED BOLT AND THE STRUTS ON THE FRAME WERE SMART FX STRUTS. THE PATIENT IS HEALING AS EXPECTED, WEIGHT-BEARING, AND IS NOT NEUROPATHIC. IT IS UNKNOWN IF/WHEN WIRE REPLACEMENT WAS CONDUCTED.
Patient problems: Failure of Implant
MAUDE report 18234279 ↗InjuryNov 15, 2023Fracture; Fracture
IT WAS REPORTED THAT, DURING ILIZAROV EXTERNAL FIXATION TREATMENT, THE PATIENT EXPERIENCED TWO (2) WIRE BREAKAGES ON (B)(6) 2023. THE WIRES WERE REPLACED. THE TSF CONFIGURATION IS TWO RINGS, THREE PINS PROXIMALLY, NO ADVERSE OBSERVATIONS. WIRE FIXATION BOLT USED ARE CONVENTIONAL ILIZAROV SLOTTED BOLT AND THE STRUTS ON THE FRAME WERE SMART FX STRUTS. THE PATIENT IS HEALING AS EXPECTED, WEIGHT-BEARING, AND IS NOT NEUROPATHIC.
Patient problems: Failure of Implant
MAUDE report 18145255 ↗MalfunctionMay 6, 2019Break; Break
IT WAS REPORTED THAT THE PATIENT CAME INTO CLINIC AND REPORTED THAT 2 WIRES ON HER FRAME HAD SNAPPED.. THEREFORE, 2 WIRE BROKEN CLOSE TO THE FRAME OUTSIDE THE BODY AND 1 BROKE INTERNALLY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8582960 ↗MalfunctionMay 6, 2019Break; Break
IT WAS REPORTED THAT THE PATIENT CAME INTO CLINIC AND REPORTED THAT 2 WIRES ON HER FRAME HAD SNAPPED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8582957 ↗InjuryDec 28, 2018Break; Break
IT WAS REPORTED THAT A REVISION SURGERY WAS PERFORMED BECAUSE THE WIRE SNAPPED ON TSF FRAME AT WIRE FIXATION BOLT INTERFACE DURING PATIENT WEIGHT BEARING.
Patient problems: Injury
MAUDE report 8205070 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K994143. One submission often covers many models, so check the product and lot details in each record.
- Z-1750-2012 · Apr 13, 2012 · TerminatedJET-X(R) 6 MM X 30 MM SHORT HALF PIN TI-6AL-4V, REF 71056308, QTY: (1), STERILE R, Smith & Nephew, Inc., Memphis, TN 38116 Orthopedic surgical device.
- Z-1765-2012 · Apr 13, 2012 · TerminatedJET-X(R) 5 MM X 55 MM SHORT HALF PIN TI-6AL-4V, REF 71055551, QTY: (1), STERILE R, Smith & Nephew, Inc., Memphis, TN 38116 Orthopedic surgical device.
- Z-1761-2012 · Apr 13, 2012 · TerminatedJET-X(R) 5 MM X 30 MM SHORT HALF PIN TI-6AL-4V, REF 71055301, QTY: (1), STERILE R, Smith & Nephew, Inc., Memphis, TN 38116 Orthopedic surgical device.
- Z-1762-2012 · Apr 13, 2012 · TerminatedJET-X(R) 5 MM X 35 MM SHORT HALF PIN TI-6AL-4V, REF 71055351, QTY: (1), STERILE R, Smith & Nephew, Inc., Memphis, TN 38116 Orthopedic surgical device.
- Z-1748-2012 · Apr 13, 2012 · TerminatedJET-X(R) 6 MM X 20 MM SHORT HALF PIN TI-6AL-4V, REF 71056208, QTY: (1), STERILE R, Smith & Nephew, Inc., Memphis, TN 38116 Orthopedic surgical device.
- Z-1760-2012 · Apr 13, 2012 · TerminatedJET-X(R) 5 MM X 25 MM SHORT HALF PIN TI-6AL-4V, REF 71055251, QTY: (1), STERILE R, Smith & Nephew, Inc., Memphis, TN 38116 Orthopedic surgical device.
- Z-1752-2012 · Apr 13, 2012 · TerminatedJET-X(R) 6 MM X 40 MM SHORT HALF PIN TI-6AL-4V, REF 71056408, QTY: (1), STERILE R, Smith & Nephew, Inc., Memphis, TN 38116 Orthopedic surgical device.
- Z-1747-2012 · Apr 13, 2012 · TerminatedJET-X(R) BAR 5 MM X 45 MM BAR SHORT HALF PIN TI-6AL-4V, REF 71055451, QTY: (1), STERILE R, Smith & Nephew, Inc., Memphis, TN 38116 Orthopedic surgical device.
- Z-1759-2012 · Apr 13, 2012 · TerminatedJET-X(R) 5 MM X 20 MM SHORT HALF PIN TI-6AL-4V, REF 71055201, QTY: (1), STERILE R, Smith & Nephew, Inc., Memphis, TN 38116 Orthopedic surgical device.
- Z-1758-2012 · Apr 13, 2012 · TerminatedJET-X(R) 6 MM X 70 MM SHORT HALF PIN TI-6AL-4V, REF 71056708, QTY: (1), STERILE R, Smith & Nephew, Inc., Memphis, TN 38116 Orthopedic surgical device.
- Z-1751-2012 · Apr 13, 2012 · TerminatedJET-X(R) 6 MM X 35 MM SHORT HALF PIN TI-6AL-4V, REF 71056358, QTY: (1), STERILE R, Smith & Nephew, Inc., Memphis, TN 38116 Orthopedic surgical device.
- Z-1756-2012 · Apr 13, 2012 · TerminatedJET-X(R) 6 MM X 60 MM SHORT HALF PIN TI-6AL-4V, REF 71056608, QTY: (1), STERILE R, Smith & Nephew, Inc., Memphis, TN 38116 Orthopedic surgical device.
- Z-1754-2012 · Apr 13, 2012 · TerminatedJET-X(R) 6 MM X 50 MM SHORT HALF PIN TI-6AL-4V, REF 71056508, QTY: (1), STERILE R, Smith & Nephew, Inc., Memphis, TN 38116 Orthopedic surgical device.
- Z-1749-2012 · Apr 13, 2012 · TerminatedJET-X(R) 6 MM X 25 MM SHORT HALF PIN TI-6AL-4V, REF 71056258, QTY: (1), STERILE R, Smith & Nephew, Inc., Memphis, TN 38116 Orthopedic surgical device.
- Z-1757-2012 · Apr 13, 2012 · TerminatedJET-X(R) 6 MM X 65 MM SHORT HALF PIN TI-6AL-4V, REF 71056658, QTY: (1), STERILE R, Smith & Nephew, Inc., Memphis, TN 38116 Orthopedic surgical device.
…and 4 more.
Other PIN, FIXATION, THREADED devices
- ORTHOFIX MODULSYSTEM 1Orthofix Srl · Pin, Fixation, Threaded1 recall2 reports
- ORTHOFIX MODULSYSTEM 1Orthofix Srl · Pin, Fixation, Threaded1 recall0 reports
- ORTHOFIX MODULSYSTEM 1Orthofix Srl · Pin, Fixation, Threaded1 recall0 reports
- ORTHOFIX MODULSYSTEM 1Orthofix Srl · Pin, Fixation, Threaded1 recall0 reports
- APEX 5038-1-080Stryker GmbH · PIN, FIXATION, THREADED48 reports
- Agee Digit Widget® DWD-232Hand Biomechanics Lab Inc · Pin, Fixation, Threaded32 reports
- SPATIAL FRAME 71070720Smith & Nephew, Inc. · PIN, FIXATION, THREADED15 reports
- APEX 5038-2-110Stryker GmbH · PIN, FIXATION, THREADED11 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.