3M™ Micropore™ 1533-1Recalls & reported problems
3m Company · 3M™ Micropore™ Tape, Tan, 1 inch X 10 yards, 12 Rolls/Carton, 10 Cartons/Case, 1533-1 · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 30707387066018), received between Jun 9, 2021 and Jun 9, 2021 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Erythema1
- Skin Inflammation/ Irritation1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJun 9, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
RECEIVED FROM (B)(6): A PATIENT HAD AN OPERATION DUE TO UNDERARM ODOR AND 3M¿ MICROPORE¿ SURGICAL TAPE WAS APPLIED AFTER THE PROCEDURE. ABOUT 30 MINUTES LATER, SKIN REDNESS, ITCHINESS, SWELLING AND A FEW BLISTERS RESULTED IN THE TAPE APPLICATION AREA. THE SKIN WAS WIPED WITH ALCOHOL, DEXAMETHASONE WAS GIVEN INTRAVENOUSLY AND APPLIED TOPICALLY TO THE SKIN, AND THE AREA WAS NO LONGER COVERED WITH 3M TAPES AND ELASTIC BANDAGES. AFTER TREATMENT, THE SYMPTOMS WERE ALLEVIATED.
Patient problems: Erythema; Skin Inflammation/ Irritation
MAUDE report 11970320 ↗
Other Tape and bandage, adhesive devices
- IV3000-1-HAND 10X12CM-CARTON OF 50 66024008Smith & Nephew Medical Limited · Tape And Bandage, Adhesive62 reports
- CURAD NON25600QSMedline Industries, Inc. · Tape and bandage, adhesive1 recall2 reports
- IV3000-1-HAND 6X7CM-CARTON OF 100 66024007Smith & Nephew Medical Limited · Tape And Bandage, Adhesive52 reports
- CURAD NON25650QSMedline Industries, Inc. · Tape and bandage, adhesive1 recall1 report
- 3M™ 1500U3m Company · Tape and bandage, adhesive1 recall1 report
- Lucky Super Soft Bandages in differenet sizeDelta Brands Inc. · Tape And Bandage, Adhesive1 recall0 reports
- 3M™ Durapore™ 1538-1183M Deutschland GmbH · Tape and bandage, adhesive1 recall0 reports
- CURAD NON256133QSMedline Industries, Inc. · Tape and bandage, adhesive1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page