Mallinckrodt 125137Recalls & reported problems
Covidien LP · Endobronchial Tube Left with CPAP;Endobronchial Suction Catheter;Endobronchial Tube Accessories · Class 2
All models of Mallinckrodt (73)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 30884522008697), received between Sep 14, 2018 and Sep 14, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Component Missing” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Component Missing1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 14, 2018Component Missing; Component Missing
ACCORDING TO THE REPORTER, THE DEVICE HAD MISSING COMPONENTS AND COULD NOT BE USED. THERE WAS NO PATIENT INJURY. NO OTHER INFORMATION WAS PROVIDED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7876784 ↗
FDA clearance and classification
Cleared through 510(k) K912240 on Aug 22, 1991 (decision: Substantially Equivalent). Submitted by Mallinckrodt Anesthesia Products as “Cpap System And Broncho-Cath W/Cpap System”. The FDA review took 93 days. FDA record ↗
The FDA regulates product code BYE (attachment, breathing, positive end expiratory pressure) under 21 CFR 868.5965 as a Class II device. 21 CFR 868.5965 ↗
The FDA lists this type of device as life-sustaining or life-supporting.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Mallinckrodt 125137
Has the Mallinckrodt 125137 been recalled?
No FDA recall record in our data names this exact device identifier (DI 30884522008697), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Mallinckrodt 125137?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Sep 14, 2018. That report lists device problem “Component Missing” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Mallinckrodt 125137?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Mallinckrodt 125137 FDA approved?
It was cleared through 510(k) K912240 on Aug 22, 1991. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the Mallinckrodt 125137 MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.
Who makes the Mallinckrodt 125137, and is it still sold?
The FDA's device database lists Covidien LP as the company responsible for it (brand Mallinckrodt, model 125137). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Attachment, breathing, positive end expiratory pressure devices
- N/A 1002Galemed Corporation · Attachment, Breathing, Positive End Expiratory Pressure1 recall1 report
- WaterPAP™ WP-7700Sunmed, LLC · Attachment, Breathing, Positive End Expiratory Pressure1 recall0 reports
- N/A 1030Galemed Corporation · Attachment, Breathing, Positive End Expiratory Pressure1 recall0 reports
- VentStar Resuscitaire CEU MP00310Drägerwerk AG & Co. KGaA · Attachment, Breathing, Positive End Expiratory Pressure1 recall0 reports
- Pneupac 100/905/340-CHIcu Medical, Inc. · Attachment, breathing, positive end expiratory pressure18 reports
- Shiley 125139Covidien LP · Attachment, breathing, positive end expiratory pressure1 death6 reports
- Shiley 125137Covidien LP · Attachment, breathing, positive end expiratory pressure4 reports
- Pneupac 100/905/340Icu Medical, Inc. · Attachment, breathing, positive end expiratory pressure3 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page