Universal Neuro 3 56-15034Recalls & reported problems
Stryker Leibinger GmbH & Co. KG · Screw, AXS, self-tapping · Class 2 · Implant
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 37613327090711), received between Sep 28, 2018 and Apr 21, 2022 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Break1
- Detachment of Device or Device Component1
- Fracture1
Patient problems
- Foreign Body In Patient1
- No Clinical Signs, Symptoms or Conditions1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 21, 2022Fracture; Fracture
IT WAS REPORTED THAT DURING THE PROCEDURE, WHILE SCREWING INTO PLACE, THE SCREW HEADS BROKE OFF AND SURGEON LEFT THE SCREW SHAFT IN THE BONE.
Patient problems: Foreign Body In Patient; No Clinical Signs, Symptoms or Conditions
MAUDE report 14174800 ↗MalfunctionSep 28, 2018Break; Detachment of Device or Device Component
IT WAS REPORTED BY THE COMPANY REPRESENTATIVE THAT THE SCREW HEAD BROKE OFF DURING INSERTION. THE BODY OF THE SCREW WAS LEFT IN THE PATIENT. THERE WAS NO ADVERSE CONSEQUENCE NOR DELAY OF SURGERY REPORTED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7920223 ↗
FDA clearance and classification
Cleared through Special 510(k) K151387 on Jun 24, 2015 (decision: Substantially Equivalent). Submitted by Stryker as “Stryker Universal Neuro III System: UN III AXS Screw, UN III AXS Screwdriver Blade”. The FDA review took 29 days. FDA record ↗
The FDA regulates product code HBW (fastener, plate, cranioplasty) under 21 CFR 882.5360 as a Class II device. 21 CFR 882.5360 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Universal Neuro 3 56-15034
Has the Universal Neuro 3 56-15034 been recalled?
No FDA recall record in our data names this exact device identifier (DI 37613327090711), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Universal Neuro 3 56-15034?
The FDA's MAUDE database lists 2 adverse event reports for this device, received between Sep 28, 2018 and Apr 21, 2022. In those reports, the most common specific device problems are “Break” (1), “Detachment of Device or Device Component” (1) and “Fracture” (1); the most common patient problem is “Foreign Body In Patient” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Universal Neuro 3 56-15034?
None of the reports are classified as deaths, 0 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Universal Neuro 3 56-15034 FDA approved?
It was cleared through Special 510(k) K151387 on Jun 24, 2015. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the Universal Neuro 3 56-15034 MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.
Who makes the Universal Neuro 3 56-15034, and is it still sold?
The FDA's device database lists Stryker Leibinger GmbH & Co. KG as the company responsible for it (brand Universal Neuro 3, model 56-15034). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other FASTENER, PLATE, CRANIOPLASTY devices
- RapidSorb 530.553.01SSynthes GmbH · FASTENER, PLATE, CRANIOPLASTY1 recall0 reports
- "1.5MM" SYSTEM 95-6104Biomet Microfixation, Inc · FASTENER, PLATE, CRANIOPLASTY30 reports
- "1.5MM" SYSTEM 95-6105Biomet Microfixation, Inc · FASTENER, PLATE, CRANIOPLASTY16 reports
- UNIVERSAL NEURO 3 56-15904Stryker Leibinger GmbH & Co. KG · FASTENER, PLATE, CRANIOPLASTY7 reports
- 1.5MM SYSTEM 91-6104-50Biomet Microfixation, Inc · FASTENER, PLATE, CRANIOPLASTY6 reports
- 1.5MM SYSTEM 91-6105XBiomet Microfixation, Inc · FASTENER, PLATE, CRANIOPLASTY5 reports
- Universal Neuro 3 56-15934Stryker Leibinger GmbH & Co. KG · FASTENER, PLATE, CRANIOPLASTY4 reports
- Universal Neuro 3 56-15935Stryker Leibinger GmbH & Co. KG · FASTENER, PLATE, CRANIOPLASTY2 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page