ELEOS™ KTAGB305ERecalls & reported problems
Onkos Surgical, Inc. · TIBIAL AUGMENT, NONPOROUS, SIZE 3 X 5MM · Class 2 · Implant
All models of ELEOS (127)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 5
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI B278KTAGB305E0), received between Oct 5, 2021 and Aug 31, 2022 — classified as 5 injuries.
11 other recalls cover devices cleared under the same FDA submission (K161520); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem5
Patient problems
- Unspecified Infection5
- Insufficient Information2
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
InjuryAug 31, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A PATIENT EXPERIENCED AN INFECTION AND UNDERWENT A REVISION SURGERY ON (B)(6) 2022. THE FOLLOWING IMPLANTS WERE REMOVED DURING THE REVISION: ELEOS DISTAL FEMUR AXIAL PIN, ELEOS TIBIAL HINGE W/ ROTATIONAL STOP AND ELEOS TIBIAL POLY SPACER.
Patient problems: Insufficient Information; Unspecified Infection
MAUDE report 15332467 ↗InjuryAug 31, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A PATIENT EXPERIENCED AN INFECTION AND UNDERWENT A REVISION SURGERY ON (B)(6) 2022. THE FOLLOWING IMPLANTS WERE REMOVED DURING THE REVISION: ELEOS DISTAL FEMUR AXIAL PIN, ELEOS TIBIAL HINGE W/ ROTATIONAL STOP AND ELEOS TIBIAL POLY SPACER.
Patient problems: Insufficient Information; Unspecified Infection
MAUDE report 15332460 ↗InjuryNov 15, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT UNDERWENT A REVISION SURGERY ON (B)(6) 2021 DUE TO AN ALLEGED INFECTION. DURING THE REVISION SURGERY, THE FOLLOWING ELEOS IMPLANTS WERE REVISED: DISTAL FEMUR AXIAL PIN, TIBIAL POLY SPACER, AND TIBIAL HINGE COMPONENT. THE SURGEON PERFORMED A WASHOUT. THE FOLLOWING ELEOS IMPLANTS REMAIN IMPLANTED FROM THE ORIGINAL SURGERY: CANAL-FILLING SEGMENTAL STEM, MALE-FEMALE MIDSECTION, DISTAL FEMUR, TIBIAL BASEPLATE, (2) TIBIAL BLOCK AUGMENTS, AND CANAL-FILLING STEM EXTENSION. NO ADDITIONAL INFORMATION REGARDING THIS ADVERSE EVENT HAS BEEN PROVIDED.
Patient problems: Unspecified Infection
MAUDE report 12816942 ↗InjuryOct 5, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT UNDERWENT A REVISION SURGERY ON (B)(6) 2021 DUE TO AN ALLEGED INFECTION. DURING THE REVISION SURGERY, THE FOLLOWING IMPLANTS WERE REVISED: ELEOS DISTAL FEMUR AXIAL PIN, ELEOS DISTAL FEMUR, ELEOS TIBIAL POLY SPACER, ELEOS SEGMENTAL STEM, AND ELEOS TIBIAL HINGE COMPONENT. ADDITIONAL INFORMATION WAS RECEIVED THAT IDENTIFIED THE FOLLOWING IMPLANTS REMAIN IMPLANTED FROM THE PATIENT'S ORIGINAL ELEOS SURGERY: TIBIAL BASEPLATE, 2 TIBIAL BLOCK AUGMENTS, STEM EXTENSION, AND MODULAR TIBIAL BASE STEM CAP. ADDITIONAL INFORMATION REGARDING THIS EVENT HAS NOT BEEN PROVIDED.
Patient problems: Unspecified Infection
MAUDE report 12576707 ↗InjuryOct 5, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT UNDERWENT A REVISION SURGERY ON (B)(6) 2021 DUE TO AN ALLEGED INFECTION. DURING THE REVISION SURGERY, THE FOLLOWING IMPLANTS WERE REVISED: ELEOS DISTAL FEMUR AXIAL PIN, ELEOS DISTAL FEMUR, ELEOS TIBIAL POLY SPACER, ELEOS SEGMENTAL STEM, AND ELEOS TIBIAL HINGE COMPONENT. ADDITIONAL INFORMATION WAS RECEIVED THAT IDENTIFIED THE FOLLOWING IMPLANTS REMAIN IMPLANTED FROM THE PATIENT'S ORIGINAL ELEOS SURGERY: TIBIAL BASEPLATE, 2 TIBIAL BLOCK AUGMENTS, STEM EXTENSION, AND MODULAR TIBIAL BASE STEM CAP. ADDITIONAL INFORMATION REGARDING THIS EVENT HAS NOT BEEN PROVIDED.
Patient problems: Unspecified Infection
MAUDE report 12576704 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K161520. One submission often covers many models, so check the product and lot details in each record.
- Z-2424-2025 · Jul 11, 2025 · Open, ClassifiedELEOS SEGMENTAL LIMB SALVAGE SYSTEM, ELEOS SEGMENTAL STEM CANAL FILLING STRAIGHT SLOTTED SPLINED 2/3 PLASMA. Canal filling stem implants.
- Z-2425-2025 · Jul 11, 2025 · Open, ClassifiedELEOS SEGMENTAL LIMB SALVAGE SYSTEM, ELEOS STEM EXTENSION, STRAIGHT, SPLINED, SLOTTED. Canal filling stem implants.
- Z-2423-2025 · Jul 11, 2025 · Open, ClassifiedELEOS SEGMENTAL LIMB SALVAGE SYSTEM, ELEOS BOWED CANAL FILLING STEMS. Canal filling stem implants.
- Z-1857-2025 · Sep 22, 2024 · Open, ClassifiedELEOS MALE-FEMALE MIDSECTION 40MM. Part Number: 25001040E. Component of ELEOS Limb Salvage System
- Z-1879-2025 · Sep 1, 2023 · Open, Classifieda. Segmental Stem, Cemented, Straight, 100MM, 1 EACH; Model Numbers: CS-09100-03M, CS-10100-03M. b. Segmental Stem, Cemented, Straight, 120MM, 1 EACH. Model Numbers: CS-11120-03M,
- Z-1882-2025 · Sep 1, 2023 · Open, ClassifiedSegmental Stem, Canal Filling, Bowed 152MM, 1 EACH. Model Numbers: FB-11152-03M, FB-12152-03M, FB-13152-03M, FB-14152-03M, FB-15152-03M, FB-16152-03M, FB-17152-03M, FB-18152-03M, F
- Z-1884-2025 · Sep 1, 2023 · Open, ClassifiedMale-Female Midsection with the following sizes and model numbers. a. Male-Female Midsection, 40mm, 1 EACH; Model Number: 25001040E b. Male-Female Midsection, 50mm, 1 EACH; Model
- Z-1881-2025 · Sep 1, 2023 · Open, ClassifiedSegmental Stem, Canal Filling, Straight, 120MM, 1 EACH. Model Numbers: FS-11120-03M, FS-12120-03M, FS-13120-03M, FS-14120-03M, FS-15120-03M, FS-16120-03M, FS-17120-03M, FS-18120-03
- Z-2648-2017 · May 23, 2017 · TerminatedELEOS LIMB SALVAGE SYSTEM SEGMENTAL STEM, CANAL FILLING, DIAMETER 20MM, LENGTH 120MM, STYLE STRAIGHT, TYPE CANAL FILLING, COLLAR 25MM; REF 2500SP22E
- Z-2646-2017 · May 23, 2017 · TerminatedELEOS LIMB SALVAGE SYSTEM SEGMENTAL STEM, CANAL FILLING, DIAMETER 18MM, LENGTH 120MM, STYLE STRAIGHT, TYPE CANAL FILLING, COLLAR 25MM, REF 2500SP18E
- Z-2647-2017 · May 23, 2017 · TerminatedELEOS LIMB SALVAGE SYSTEM SEGMENTAL STEM, CANAL FILLING, DIAMETER 20MM, LENGTH 120MM, STYLE STRAIGHT, TYPE CANAL FILLING, COLLAR 25MM; REF 2500SP20E
Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices
- ATTUNE 1506-00-005Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER589 reports
- ATTUNE 1506-00-004Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER580 reports
- JOURNEY 74012812Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER502 reports
- JOURNEY 74011856Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER438 reports
- PERSONA™ 42-5099-094-00Zimmer, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER406 reports
- JOURNEY 74011857Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER388 reports
- ATTUNE 1506-00-007Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER288 reports
- ATTUNE 1506-00-003Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER271 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page