Skip to content

ESI 15-4010Recalls & reported problems

Ftt Medical, Inc. · SALVATI OPERATING PROCTOSCOPE, 4CM X 19CM, STAINLESS. ACMI FITTING. · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI B3961540100), received between Aug 18, 2026 and Aug 18, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Defective Device” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Defective Device1
  • Device Reprocessing Problem1
  • Use of Device Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 18, 2026Device Reprocessing Problem; Use of Device Problem; Defective Device

    ESI-ElectroSurgical Instrumest Salvati Proctoscope 15-4010: Multiple product (2)arrived new, was reprocessed once each using manual cleaning with FDA registeredcleaning agent prepared per IFU and AAMI water standards; sent through FDAregistered washer/disinfector using a FDA registered cleaning agent prepared per IFU.All device reprocessing instructions followed as required per the manufacturer IFU.Product was then packaged and sterilized with a STERIS FDA registered autoclave atthe pre-vacuum steam sterilization parameters per the device IFU at 270*F, 4-minuteexposure. Once completed product was opened to be used for a patient procedure andwas found to be defective. The Salvati proctoscope consists of 2 pieces, an innerplastic piece and an outer metal piece. After reprocessing 1-time, the inner plasticpiece could not be assembled into the outer metal piece and unable to be used. Thesurgeon had to used rectal retractor's instead creating a less than ideal surgicalsituation. No harm was done and procedure was completed. A second Salvati waspurchased new and the exact same issue occurred. Both Salvati proctoscopes couldnot be used due to the inner plastic piece not fitting into the o

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50302190 ↗

FDA clearance and classification

The FDA regulates product code GCF (proctoscope) under 21 CFR 876.1500 as a Class II device. 21 CFR 876.1500 ↗

Devices of this type normally need 510(k) clearance before sale.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the ESI 15-4010

Has the ESI 15-4010 been recalled?

No FDA recall record in our data names this exact device identifier (DI B3961540100), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the ESI 15-4010?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Aug 18, 2026. That report lists device problems “Defective Device” (1), “Device Reprocessing Problem” (1) and “Use of Device Problem” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the ESI 15-4010?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Who makes the ESI 15-4010, and is it still sold?

The FDA's device database lists Ftt Medical, Inc. as the company responsible for it (brand ESI, model 15-4010). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Proctoscope devices

All Proctoscope devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page