MULTI HOLE 6 20121800Recalls & reported problems
The Wells Johnson Company · Cannula, Multi Hole 6, Infiltration, specify length, diameter, tip shape and handle/hub · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI B458201218000), received between Jul 14, 2025 and Jul 14, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Material Separation” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Material Separation1
- Solder Joint Fracture1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 14, 2025Material Separation; Solder Joint Fracture; Material Separation; Solder Joint Fracture
THE CUSTOMER REPORTED THAT DURING A LIPOSUCTION PROCEDURE, THE CANNULA SHAFT DETACHED FROM THE BASE. THE PROCEDURE WAS COMPLETED USING AN ALTERNATE CANNULA, AND THERE WERE NO REPORTED INJURIES OR PROCEDURAL DELAYS. THE DEVICE WAS RETURNED FOR EVALUATION. VISUAL INSPECTION CONFIRMED THAT THE CANNULA SHAFT WAS BENT AND HAD SEPARATED FROM THE BASE. THE SOLDER JOINT WAS FRACTURED, AND A DENT WAS OBSERVED IN THE STAINLESS-STEEL HUB, INDICATING MECHANICAL STRESS. A REVIEW OF THE DEVICE HISTORY RECORD CONFIRMED THE PRODUCT MET ALL MANUFACTURING SPECIFICATIONS AND PASSED INSPECTION WITH NO NONCONFORMITIES OR DEVIATIONS NOTED. THE INSTRUCTIONS FOR USE (MKT-2901 REV. 01) FOR CANNULAS ADVISES AGAINST BENDING OR APPLYING EXCESSIVE FORCE TO THE DEVICE, AS THESE ACTIONS MAY COMPROMISE STRUCTURAL INTEGRITY. THE TOTALITY OF THE EVIDENCE INDICATES THAT THE DEVICE WAS MANUFACTURED ACCORDING TO SPECIFICATIONS AND THAT NO MANUFACTURING DEFICIENCIES WERE IDENTIFIED. THE OBSERVED DAMAGE IS CONSISTENT WITH MECHANICAL FORCE APPLIED BY THE USER AND IS ATTRIBUTED TO HANDLING OR USE THAT DEVIATES FROM THE CONDITIONS DESCRIBED IN THE INSTRUCTIONS FOR USE. THIS INCIDENT IS CONSIDERED ISOLATED, AS NO OTHER COMP
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22497544 ↗
Other Cannula, Surgical, General & Plastic Surgery devices
- EXPEDIUM 279712580Medos International Sàrl · CANNULA, SURGICAL, GENERAL & PLASTIC SURGERY69 reports
- AESCULAP MD610Aesculap, Inc. · CANNULA, SURGICAL, GENERAL & PLASTIC SURGERY1 recall0 reports
- ENDOPATH TT012Ethicon Endo-Surgery, LLC · CANNULA, SURGICAL, GENERAL & PLASTIC SURGERY47 reports
- NA 03.168.013Synthes GmbH · CANNULA, SURGICAL, GENERAL & PLASTIC SURGERY37 reports
- NA 214120Medos International Sàrl · CANNULA, SURGICAL, GENERAL & PLASTIC SURGERY28 reports
- Monoject 8881540111Cardinal Health, Inc. · CANNULA, SURGICAL, GENERAL & PLASTIC SURGERY19 reports
- MOSS 279712500Depuy Spine, LLC · CANNULA, SURGICAL, GENERAL & PLASTIC SURGERY12 reports
- Monoject 8881540133Cardinal Health, Inc. · CANNULA, SURGICAL, GENERAL & PLASTIC SURGERY10 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.