Genesis Implant System G21150Recalls & reported problems
Keystone Dental, Inc. · Implant · Class 2 · Implant
All models of Genesis Implant System (22)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
Quick summary
This Keystone Dental Genesis implant is a root-form dental implant placed in the jawbone. The 37 reports mostly describe the implant failing to bond with the surrounding bone or later losing that bond, along with pain at the site. No deaths were reported; all 37 reports describe injuries. No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 37
- Deaths reported
- 0
- Injuries reported
- 37
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 37 adverse event reports that list this exact device (DI D768G211500), received between Dec 30, 2019 and Apr 26, 2026 — classified as 37 injuries.
The most frequently reported specific device problem is “Failure to Osseointegrate” (23 reports).
3 other recalls cover devices cleared under the same FDA submission (K101545); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Failure to Osseointegrate23
- Loss of Osseointegration13
- Patient-Device Incompatibility1
Patient problems
- Inadequate Osseointegration22
- Failure of Implant13
- Implant Pain7
- High Blood Pressure/ Hypertension5
- Osteopenia/ Osteoporosis4
- Pain3
- Unspecified Infection2
- Bacterial Infection1
Recent adverse event reports
The 25 most recent of 37 reports, in the reporter's own words as published by the FDA.
InjuryApr 26, 2026Loss of Osseointegration
InjurySep 9, 2025Failure to Osseointegrate; Failure to Osseointegrate
InjuryJul 11, 2025Loss of Osseointegration; Loss of Osseointegration
LOSS OF OSSEOINTEGRATION.
Patient problems: Inadequate Osseointegration; Osteopenia/ Osteoporosis
MAUDE report 22484273 ↗InjuryJun 5, 2025Failure to Osseointegrate; Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: Implant Pain; Inadequate Osseointegration
MAUDE report 22152287 ↗InjuryApr 28, 2025Loss of Osseointegration; Loss of Osseointegration
LOSS OF OSSEOINTEGRATION.
Patient problems: High Blood Pressure/ Hypertension; Implant Pain; Inadequate Osseointegration
MAUDE report 21917633 ↗InjuryMar 10, 2025Loss of Osseointegration; Loss of Osseointegration
LOSS OF OSSEOINTEGRATION.
Patient problems: Implant Pain; Inadequate Osseointegration; Osteopenia/ Osteoporosis
MAUDE report 21561144 ↗InjuryDec 27, 2024Failure to Osseointegrate; Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: Implant Pain; Inadequate Osseointegration
MAUDE report 21026217 ↗InjuryMay 7, 2024Failure to Osseointegrate; Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: High Blood Pressure/ Hypertension; Inadequate Osseointegration; Osteopenia/ Osteoporosis
MAUDE report 19259281 ↗InjuryApr 19, 2024Failure to Osseointegrate; Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: High Blood Pressure/ Hypertension; Inadequate Osseointegration
MAUDE report 19148559 ↗InjuryJan 17, 2024Failure to Osseointegrate; Failure to Osseointegrate
InjuryOct 16, 2023Loss of Osseointegration; Loss of Osseointegration
LOSS OF OSSEOINTEGRATION.
Patient problems: Implant Pain; Inadequate Osseointegration; Osteopenia/ Osteoporosis
MAUDE report 17939082 ↗InjuryJul 19, 2023Failure to Osseointegrate; Failure to Osseointegrate
InjuryJun 26, 2023Loss of Osseointegration; Loss of Osseointegration
InjuryMay 31, 2023Failure to Osseointegrate; Failure to Osseointegrate
InjuryMay 12, 2023Failure to Osseointegrate; Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: High Blood Pressure/ Hypertension; Implant Pain; Inadequate Osseointegration
MAUDE report 16919442 ↗InjuryApr 13, 2023Failure to Osseointegrate; Failure to Osseointegrate
InjuryApr 4, 2023Loss of Osseointegration; Loss of Osseointegration
InjuryFeb 20, 2023Failure to Osseointegrate; Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: High Blood Pressure/ Hypertension; Implant Pain; Inadequate Osseointegration
MAUDE report 16405764 ↗InjuryOct 27, 2022Failure to Osseointegrate; Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: Failure of Implant; Inadequate Osseointegration
MAUDE report 15685788 ↗InjuryOct 27, 2022Failure to Osseointegrate; Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: Failure of Implant; Inadequate Osseointegration
MAUDE report 15685764 ↗InjuryOct 27, 2022Loss of Osseointegration; Loss of Osseointegration
InjuryOct 25, 2022Loss of Osseointegration; Loss of Osseointegration
LOSS OF OSSEOINTEGRATION.
Patient problems: Failure of Implant; Inadequate Osseointegration
MAUDE report 15670447 ↗InjuryOct 25, 2022Failure to Osseointegrate; Failure to Osseointegrate
InjuryJul 8, 2022Failure to Osseointegrate; Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: Failure of Implant; Inadequate Osseointegration
MAUDE report 14961406 ↗InjuryFeb 17, 2022Failure to Osseointegrate; Failure to Osseointegrate
Recalls under the same FDA submission
These recalls involve devices cleared under K101545. One submission often covers many models, so check the product and lot details in each record.
- Z-1485-2018 · Mar 13, 2018 · TerminatedGenesis Surgical Cassette Tapered Implants are intended for placement following natural tooth loss or for immediate placement into an extraction socket
- Z-0924-2013 · Jul 5, 2011 · TerminatedGenesis Straight Esthetic 5.0 mm 3. mm Cuff Abutment Part Number: G71205 Genesis implant for single stage or two stage surgical procedures all types of of bone in partially or ful
- Z-0923-2013 · Jul 5, 2011 · TerminatedGenesis Straight Esthetic 4.0 mm 1mm Cuff Abutment Part Number: G71200 Genesis implant for single stage or two stage surgical procedures all types of of bone in partially or fully
Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM43,616 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM40,404 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM27,400 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,621 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLA Titanium BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,298 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM23,448 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,320 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,267 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.