Skip to content

XiVE® 32262452 (REF 26-2452)Recalls & reported problems

Dentsply Implants Manufacturing GmbH · XiVE® S plus Implant D4.5/L11 · Class 2 · Implant

All models of XiVE (62)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI EFRI322624522), received between Jul 27, 2016 and Apr 17, 2025 — classified as 2 injuries.

The most frequently reported specific device problem is “Loss of Osseointegration” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Loss of Osseointegration2
  • Appropriate Device Problem Term/Code Not Available1

Patient problems

  • Failure of Implant2
  • Hypersensitivity/Allergic reaction1
  • Osteolysis1
  • Pocket Erosion1
  • Reaction1
  • Unspecified Infection1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 17, 2025Loss of Osseointegration; Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Osteolysis; Pocket Erosion; Unspecified Infection

    MAUDE report 21853771 ↗
  • InjuryJul 27, 2016Loss of Osseointegration; Appropriate Device Problem Term/Code Not Available; Loss of Osseointegration

    IT WAS REPORTED THAT A XIVE S PLUS IMPLANT WAS INSERTED IN THE JAW OF A PATIENT ON (B)(6) 2013. THE IMPLANT WAS EXPOSED AND THE PATIENT STATED THAT THEY HAD ALLERGIC REACTIONS AND AN "ELECTRIC SENSATION" AFTER ONE AND A HALF YEARS. THE IMPLANT WAS REMOVED ON (B)(6) 2015.

    Patient problems: Failure of Implant; Hypersensitivity/Allergic reaction; Reaction

    MAUDE report 5826528 ↗

Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices

All IMPLANT, ENDOSSEOUS, ROOT-FORM devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page