DuraFlow 10301215Recalls & reported problems
Angiodynamics, Inc. · DuraFlow 2 - 15.5F x 48cm Chronic Hemodialysis Catheter Set (with Cuff 43cm from Tip) · Class 2 · Implant
All models of DuraFlow (6)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI H787103012150), received between Jul 21, 2016 and Jul 21, 2016 — classified as 1 injury.
The most frequently reported specific device problem is “Detachment Of Device Component” (1 report).
6 other recalls cover devices cleared under the same FDA submission (K110936); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Detachment Of Device Component1
Patient problems
- Device Embedded In Tissue or Plaque1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJul 21, 2016Detachment Of Device Component; Detachment Of Device Component
AS REPORTED (B)(6) 2016, A PATIENT OF UNKNOWN AGE AND GENDER PRESENTED FOR A CATHETER PLACEMENT. DURING THE PROCEDURE, WHILE THE TREATING PHYSICIAN WAS PLACING THE DIALYSIS CATHETER IN THE PATIENT'S GROIN, THE HANDLES OF THE VALVED SHEATH INTRODUCER BROKE OFF. AS A RESULT OF THE FRACTURE, 2 PIECES OF THE SHEATH WERE LEFT IN PATIENT'S VEIN IN THE GROIN. THE FRACTURED PIECES WERE REMOVED, AND THE PROCEDURE WAS SUCCESSFULLY COMPLETED. THERE WAS NO REPORT OF PERMANENT HARM OR INJURY TO THE PATIENT DUE TO THIS EVENT. THE REPORTED DEFECTIVE DISPOSABLE DEVICE HAS BEEN RETURNED TO THE MANUFACTURER FOR EVALUATION.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 5811754 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K110936. One submission often covers many models, so check the product and lot details in each record.
- Z-1765-2024 · Mar 18, 2024 · Open, ClassifiedDURAFLOW 2, 28CM STRAIGHT VASC-PAK PG- Indicated for use in attaining Long-Term vascular access for Hemodialysis and Apheresis. Product Number: H787103012195
- Z-1762-2024 · Mar 18, 2024 · Open, ClassifiedDURAFLOW 2, 32CM STRAIGHT BASIC KIT PG-Indicated for use in attaining Long-Term vascular access for Hemodialysis and Apheresis. Product Number: H787103012035
- Z-1761-2024 · Mar 18, 2024 · Open, ClassifiedDURAFLOW 2, 28CM STRAIGHT BASIC KIT, 1 per Bx PG-Indicated for use in attaining Long-Term vascular access for Hemodialysis and Apheresis. Product Number: H787103012021
- Z-1763-2024 · Mar 18, 2024 · Open, ClassifiedDURAFLOW 2, 55CM STRAIGHT BASIC KIT PG- Indicated for use in attaining Long-Term vascular access for Hemodialysis and Apheresis. Product Number: H787103012115
- Z-1760-2024 · Mar 18, 2024 · Open, ClassifiedDURAFLOW 2, 24CM STRAIGHT BASIC KIT -Indicated for use in attaining Long-Term vascular access for Hemodialysis and Apheresis. Product Number: H787103012015
- Z-1764-2024 · Mar 18, 2024 · Open, ClassifiedDURAFLOW 2, 24CM STRAIGHT VASC-PAK PG- Indicated for use in attaining Long-Term vascular access for Hemodialysis and Apheresis. Product Number: H787103012185
Other Catheter, hemodialysis, implanted devices
- Palindrome 8888145014Mozarc Medical US LLC · Catheter, hemodialysis, implanted1 recall312 reports
- Palindrome 8888145015Mozarc Medical US LLC · Catheter, hemodialysis, implanted2 recalls1 death219 reports
- HemoStar Long-Term Hemodialysis Catheter 5833690Bard Access Systems, Inc. · Catheter, hemodialysis, implanted2 deaths290 reports
- Palindrome 8888119369PMozarc Medical US LLC · Catheter, hemodialysis, implanted3 recalls1 death14 reports
- HemoStar Long-Term Hemodialysis Catheter 5833730Bard Access Systems, Inc. · Catheter, hemodialysis, implanted1 death141 reports
- GlidePath Long-Term Hemodialysis Catheter with Preloaded Stylet 5393230Bard Access Systems, Inc. · Catheter, hemodialysis, implanted5 deaths138 reports
- Palindrome 8888123404PMozarc Medical US LLC · Catheter, hemodialysis, implanted2 recalls1 death17 reports
- Palindrome 8888119364PMozarc Medical US LLC · Catheter, hemodialysis, implanted2 recalls1 death17 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page